Validation of target values in external quality assessment schemes for peptide hormones and tumour markers

Author(s):  
J. Seth ◽  
C. M. Sturgeon ◽  
A. R. Ellis ◽  
R. Al Sadie
Author(s):  
Eline A.E. van der Hagen ◽  
Sanne Leppink ◽  
Karin Bokkers ◽  
Carla Siebelder ◽  
Cas W. Weykamp

Abstract Objectives Hemoglobin A1c (HbA1c) is a valuable parameter in the monitoring of diabetic patients and increasingly in diagnosis of diabetes. Manufacturers continuously optimize instruments, currently the main focus is to achieve faster turnaround times. It is important that performance specifications remain of high enough standard, which is evaluated in this study for the new ARKRAY HA-8190V instrument. Methods The Clinical and Laboratory Standards Institute (CLSI) protocols EP-5, EP-9 and EP-10 were applied to investigate imprecision, bias and linearity. In addition potential interferences, performance in External Quality Assessment (EQA) and performance against the HA-8180V instrument in 220 clinical samples was evaluated. Results The HA-8190V demonstrates a CV of ≤0.8% in IFCC SI units (≤0.6% National Glycohemoglobin Standardization Program [NGSP]) at 34 and 102 mmol/mol levels (5.3 and 11.5% NGSP) and a bias of −0.1 mmol/mol (−0.01% NGSP) at a concentration of 50 mmol/mol (6.7% NGSP), but with a significant slope as compared to target values. This results in a bias of −1.0 and 0.9 mmol/mol (−2.0 and 0.9% NGSP) at the 30 and 70 mmol/mol (4.9 and 8.6% NGSP) concentration level. Simulation of participation in the IFCC certification programme results in a Silver score (bias −0.1 mmol/mol, CV 1.1%). Interference in the presence of the most important Hb variants (AS, AC, AE, AD) and elevated HbA2 and HbF concentrations is less than 3 mmol/mol (0.3% NGSP) at a concentration of 50 mmol/mol (6.7% NGSP). Conclusions Analytical performance of the HA-8190V is very good, especially with respect to precision and HbA1c quantification in the presence of the most common Hb variants.


2017 ◽  
Vol 100 (5) ◽  
pp. 1277-1287 ◽  
Author(s):  
Carolyn Q Burdette ◽  
Johanna E Camara ◽  
Federica Nalin ◽  
Jeanita Pritchett ◽  
Lane C Sander ◽  
...  

Abstract Until recently, the Vitamin D External Quality Assessment Scheme (DEQAS) assessed the performance of various assays for the determination of serum total 25-hydroxyvitamin D [25(OH)D] by using a consensus mean based on the all-laboratory trimmed mean (ALTM) of the approximately 1000 participants' results. Since October 2012, the National Institute of Standardsand Technology (NIST), as part of the Vitamin D Standardization Program, has participated in DEQAS by analyzing the quarterly serum sample sets using an isotope dilution LC-tandem MS (ID LC-MS/MS) reference measurement procedure to assign an accuracy-based target value for serum total 25(OH)D. NIST has analyzed90 DEQAS samples (18 exercises × 5 samples/exercise) to assign target values. The NIST-assigned values are compared with the ALTM and the biases assessed for various assays used by the participants, e.g., LC-MS/MS, HPLC, and several ligand-binding assays. The NIST-value assignment process and the resultsof the analyses of the 90 DEQAS samples are summarized. The absolute mean bias between the NIST-assignedvalues and the ALTM was 5.6%, with 10% of the samples having biases >10%. Benefits of the accuracy-based target values are presented, including for sample sets with high concentrations of 25(OH)D2 and 3-epi-25(OH)D3.


2020 ◽  
Vol 30 (2) ◽  
pp. 278-286
Author(s):  
Agnieszka Ćwiklińska ◽  
Barbara Kortas-Stempak ◽  
Maciej Jankowski ◽  
Gabriela Bednarczuk ◽  
Aleksandra Fijałkowska ◽  
...  

Introduction: Urine particle analysis is an important diagnostic tool. The aim of this study was to evaluate the quality of urine leukocyte (WBC) and erythrocyte (RBC) counting results obtained with manual and automated methods in Polish laboratories participating in the international external quality assessment (EQA) programme. Materials and methods: 1400 WBC and RBC counting results were obtained from 183 laboratories in EQA surveys organised by Labquality (Helsinki, Finland) from 2017 to 2019. The between-laboratory coefficient of variation (CV), the percentage difference between the laboratories' results and target values (Q-score (%)), as well as modified Youden plots were analysed. Results: For automated method groups, the medians of inter-laboratory CVs varied from 14% to 33% for WBC counting and from 10% to 39% for RBC counting. For manual method groups, the medians of CV varied from 53% to 71% (WBC) and from 55% to 70% (RBC), and they were significantly higher, in comparison to CVs for most automated method groups (P < 0.001). The highest percentage of results outside the target limits (36%) and the highest range of Q-score (%) (from - 93% to 706%) were observed for laboratories which participated in the surveys for the first or second time. The percentage of deviating results and the ranges of Q-score decreased with an increased frequency of laboratories’ participation in the surveys. Conclusions: The quality of manual methods of urine WBC and RBC counting is unsatisfactory. There is an urgent need to take actions to improve laboratories’ performance and to increase harmonisation of the results.


1993 ◽  
Vol 39 (6) ◽  
pp. 993-1000 ◽  
Author(s):  
D Stöckl ◽  
H Reinauer

Abstract In Germany, the target values for External Quality Assessment (EQA) and internal accuracy control are determined by Reference Methods for several analytes, including cholesterol, creatinine, uric acid, and glucose. We present candidate Reference Methods for these compounds, based on isotope dilution-gas chromatography--mass spectrometry methods that have been developed at INSTAND, one of the two official Germany EQA reference institutions. Each Reference Method target value is calculated from six independent measurements performed on three different days. The mean method CVs ranged from 0.66% for glucose to 0.96% for creatinine. The inaccuracy (bias) of the methods is < 0.7%, as compared with the Standard Reference Material 909 of the National Institute of Standards and Technology. The maximum total error of a Reference Method value, including the 95% confidence interval and systematic errors, is < 2.3%. The presented candidate Reference Methods have been successfully used to set target values in the German EQA scheme and the internal accuracy control of routine laboratories.


Bioanalysis ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 1743-1750
Author(s):  
Yaxin Fan ◽  
Yu Wang ◽  
Mengting Chen ◽  
Yuancheng Chen ◽  
Beining Guo ◽  
...  

Aim: To compare the difference between the measured and target values in vancomycin external quality assessment (EQA) samples and to investigate the factors for underestimating its concentration. Materials & methods: A retrospective analysis of 195 international vancomycin EQA results was performed. Deviations of the concentrations determined by TDx fluorescence polarization immunoassay (FPIA), Axsym FPIA and Architect chemiluminescence microparticle immunoassay (CMIA) method were -2.43, -16.28 and -10.53%, respectively. Chromatographic peaks of the crystalling degradation products appeared in samples with large deviations. Vancomycin were degraded after long-term transporting and high temperature. Conclusion: Vancomycin concentrations measured by Axsym FPIA and Architect CMIA methods were likely to be underestimated. Long-term transporting resulted in low EQA results, suggesting that establishing a local EQA system for vancomycin is essential.


Author(s):  
Gladys Matar ◽  
Bernard Poggi ◽  
Roland Meley ◽  
Chantal Bon ◽  
Laurence Chardon ◽  
...  

AbstractInternational organizations require from medical laboratories a quantitative statement of the uncertainty in measurement (UM) to help interpret patient results. The French accreditation body (COFRAC) recommends an approach (SH GTA 14 IQC/EQA method) using both internal quality control (IQC) and external quality assessment (EQA) data. The aim of this work was to validate an alternative way to quantify UM using only EQA results without any need for IQC data. This simple and practical method, which has already been described as the long-term evaluation of the UM (LTUM), is based on linear regression between data obtained by participants in EQA schemes and target values. We used it for 43 routine analytes covering biochemistry, immunoassay, and hemostasis fields.Data from 50 laboratories participating in ProBioQual (PBQ) EQA schemes over 25 months were used to obtain estimates of the median and 90th percentile LTUM and to compare them to the usual analytical goals. Then, the two UM estimation methods were compared using data from 20 laboratories participating in both IQC and EQA schemes.Median LTUMs ranged from 2.9% (sodium) to 16.3% (bicarbonates) for biochemistry analytes, from 12.6% (prothrombin time) to 18.4% (factor V) for hemostasis analytes when using the mean of all participants, and were around 10% for immunoassays when using the peer-group mean. Median LTUMs were, in most cases, slightly lower than those obtained with the SH GTA 14 method, whatever the concentration level.LTUM is a simple and convenient method that gives UM estimates that are reliable and comparable to those of recommended methods. Therefore, proficiency testing (PT) organizers are allowed to provide participants with an additional UM estimate using only EQA data and which could be updated at the end of each survey.