Recurrent scleral patch graft shrinkage and Ahmed valve tube exposure

2019 ◽  
Vol 11 (2) ◽  
pp. 232-236
Author(s):  
Tarannum Mansoori

Aim: To report a case of recurrent Ahmed glaucoma valve (AGV) tube exposure dueto scleral patch graft (SPG) melt Background: AGV is a useful modality in the management of medically refractory glaucoma. Human donor SPG has been employed to cover the external portion of the tube to prevent its exposure. Case Description : A 23 year old male with Anterior chamber intraocular lens (ACIOL)had undergone retinal detachment (RD) surgery with silicone oil insertion (SOI)followed by SO removal (SOR), re- RD and SO re-injection, followed by implantation of Ahmed glaucoma valve (AGV) for uncontrolled glaucoma in the right eye. Three months after the AGV implantation, he presented with exposure of the subconjuctival portion of AGV tube with melted, displaced and shrunk donor sclera graft, which was managed by placing larger sized, full thickness, donor scleral patch graft (SPG) over the exposed tube. Six months later, he presented again with tube exposure and the donor SPG was found to be retracted nasally and shrunk to one fourth of its original size. The AC portion of the tube was blocked by the SO bubble and the emulsified SO could be seen inside the exposed tube. The patient underwent SOR with tube explanation and intraocular pressure was later controlled with transscleral cyclophotocoagulation and medical management. Conclusion : SPG thinning and the overlying conjunctival erosion can occur after the AGV implantation. This can cause AGV tube exposure and hence, long - term patient follow up is essential to ensure timely identification of this possible complication and prompt treatment.

2017 ◽  
Vol 11 (3) ◽  
pp. 120-124
Author(s):  
David Fleischman ◽  
Bryan Kim

ABSTRACT Surgical management of elevated intraocular pressure (IOP) in an eye with scarred conjunctiva, an encircling band, and silicone oil has limited options. By combining the flow restrictor of the Ahmed Glaucoma Valve (New World Medical, Rancho Cucamonga, California) and the capsule of the encircling band as a conduit for aqueous flow, immediate pressure reduction could theoretically be achieved in eyes with limited conjunctival mobilization. This is a description of a surgical technique in a case of a patient with multiple ocular surgeries with uncontrolled multimechanism glaucoma despite using all available topical and oral glaucoma medications. A combination of the Ahmed valve with a modification of the Schocket shunt technique was used in this case of an encircling band and poor conjunctiva. At 10-month follow-up, the patient maintains controlled pressures on dorzolamide—timolol drops. The combined Ahmed—Schocket (or Schockmed) technique may be another surgical option for management of uncontrolled IOP in cases of scarred conjunctiva and encircling bands needing immediate pressure reduction. Schockmed valve A novel surgical option for uncontrolled glaucoma in eyes with poor conjunctiva and encircling bands. How to cite this article Fleischman D, Kim B. Schockmed Valve: A Novel Surgical Option for Uncontrolled Glaucoma in Eyes with Poor Conjunctiva and Encircling Bands. J Curr Glaucoma Pract 2017;11(3):120-124.


Author(s):  
Tomasz K. Wilczyński ◽  
Alfred Niewiem ◽  
Rafał Leszczyński ◽  
Katarzyna Michalska-Małecka

A 36-year-old patient presented to the hospital with recurrent dislocation of the intraocular lens (IOL). The patient with the diagnosis of familial ectopia lentis was first operated on for crystalline lens subluxation in the left eye in 2007 and in the right eye in 2009. In both eyes, lens extraction with anterior vitrectomy and transscleral fixation of a rigid IOL was performed. In 2011, the IOL in the right eye luxated into the vitreous cavity due to ocular trauma. The patient underwent a pars plana vitrectomy with the IOL resuturation to the sclera. Seven years later, a spontaneous vision loss in the right eye was caused by a retinal detachment. The pars plana vitrectomy with silicone oil tamponade and a consequential oil removal three months later were performed in 2018. The follow-up examination revealed recurrent IOL dislocation in the same eye. Due to a history of previous suture-related complications a decision was made to remove the subluxated rigid polymethyl-methacrylate (PMMA) IOL and fixate to sclera a sutureless SOLEKO FIL SSF Carlevale lens. The purpose of this report is to present a single case of a 36-year-old patient who was presented to the hospital with recurrent dislocation of the intraocular lens. In a three-month follow-up period, a good anatomical and functional outcome was finally obtained with transscleral sutureless intraocular lens. This lens is an option worth considering especially in a young patient with a long life expectancy and physically active.


2021 ◽  
pp. 263246362097804
Author(s):  
Vanita Arora ◽  
Pawan Suri

Anatomy and physiology are the basis of human body functioning and as we have progressed in management of various diseases, we have understood that physiological intervention is always better than an anatomical one. For more than 50 years, a standard approach to permanent cardiac pacing has been an anatomical placement of transvenous pacing lead at the right ventricular apex with a proven benefit of restoring the rhythm. However, the resultant ventricular dyssynchrony on the long-term follow-up in patients requiring more than 40% ventricular pacing led to untoward side effects in the form of heart failure and arrhythmias. To counter such adverse side effects, a need for physiological cardiac pacing wherein the electrical impulse be transmitted directly through the normal conduction system was sought. His bundle pacing (HBP) with an intriguing alternative of left bundle branch pacing (LBBP) is aimed at restoring such physiological activation of ventricles. HBP is safe, efficacious, and feasible; however, localization and placement of a pacing lead at the His bundle is challenging with existing transvenous systems due to its small anatomic size, surrounding fibrous tissue, long-learning curve, and the concern remains about lead dislodgement and progressive electrical block distal to the HBP lead. In this article, we aim to take the reader through the challenging journey of HBP with focus upon the hardware and technique, selective versus nonselective HBP, indications and potential disadvantages, and finally the future prospects.


2002 ◽  
Vol 12 (3) ◽  
pp. 224-228 ◽  
Author(s):  
Haifa Abdul Latiff ◽  
Mazeni Alwi ◽  
Hasri Samion ◽  
Geetha Kandhavel

This study reviewed the short-term outcome of transcatheter closure of the defects within the oval fossa using an Amplatzer® Septal Occluder. From January 1997 to December 2000, 210 patients with defects within the oval fossa underwent successful transcatheter closure. We reviewed a total of 190 patients with left-to-right shunts, assessing the patients for possible complications and the presence of residual shunts using transthoracic echocardiogram at 24 h, 1 month, 3 months and one year. Their median age was 10 years, with a range from 2 to 64 years, and their median weight was 23.9 kg, with a range from 8.9 to 79 kg. In 5 patients, a patent arterial duct was closed, and in 2 pulmonary balloon valvoplasty performed, at the same sitting. The median size of the Amplatzer® device used was 20 mm, with a range from 9 to 36 mm. The median times for the procedure and fluoroscopy were 95 min, with a range from 30 to 210 min, and 18.4 min, with a range from 5 to 144 min, respectively. Mean follow-up was 20.8 ± 12.4 months. Complete occlusion was obtained in 168 of 190 (88%) patients at 24 h, 128 of 133 (96.2%) at 3 months, and 103 of 104 (99%) at one year. Complications occurred in 4 (2.1%) patients. In one, the device became detached, in the second the device embolized into the right ventricular outflow tract, the lower end of the device straddled in the third, and the final patient had significant bleeding from the site of venupuncture. There were no major complications noted on follow-up. We conclude that transcatheter closure of defects within the oval fossa using the Amplatzer® Septal Occluder is safe and effective. Long-term follow-up is required, nonetheless, before it is recommended as a standard procedure.


2021 ◽  
Vol 20 (1) ◽  
pp. 15-17
Author(s):  
Caroline Apsey ◽  
◽  
Muhammad Jawad ◽  
Martin Daschel ◽  
Daniel Woosey ◽  
...  

We assessed the efficacy of thrombolysis in avoiding long-term complications. Notes of patients thrombolysed for PE in the 2-year period were reviewed. The initial CTPA and echocardiogram results before thrombolysis were compared to the results of follow up imaging repeated after 6 months. Twenty-two patients were thrombolysed for PE. 14 patients had sub-massive PE and 8 patients had massive PE. The right ventricle (RV) was dilated on pre-thrombolysis echocardiogram in 16 patients. On follow up echocardiography all patients with massive PE (6 studies) had a normal RV size, with pulmonary artery pressures (PAP) of 29mmHg. Follow up echocardiography of patients with submassive PE (13 studies) showed 11 patients with a normal RV, with PAP of 28 mmHg.


2018 ◽  
Vol 75 (5) ◽  
pp. 512-515 ◽  
Author(s):  
Sasa Hinic ◽  
Jelena Saric ◽  
Predrag Milojevic ◽  
Jelena Gavrilovic ◽  
Tijana Durmic ◽  
...  

Introduction. Myxoma is the most common primary benign heart tumor. The most frequent location is the left atrium, the chamber of the heart that receives oxygen- rich blood from the lungs. Myxomas usually develop in women, typically between the ages of 40 and 60. Symptoms may occur at any time, but most often they are asymptomatic or oligosymptomatic for a long period of time. Symptoms usually go along with body position, and are related to compression of the heart cavities, embolization and the appearance of general symptoms. The diagnosis of benign tumors of the heart is based on anamnesis, clinical features and findings of the tumor masses by use of non-invasive and invasive imaging methods. Extensive surgical resection of the myxoma is curative with minimal mortality. Long term clinical and echocardiographic follow-up is mandatory. Case report. We reported a case of a 62-year-old male, presented with 15 days of intermittent shortness of breath, dizziness and feeling of heart palpitations and subsequently diagnosed with right atrial myxoma based on transthoracic echocardiography . The patient was emergently operated in our hospital. Long-term followup did not reveal recurrence. Conclusion. Our case was an atypical localisation of right atrial myxoma. Whether the intracardiac mass is benign or malignant, early surgery is obligatory in order to prevent complications.


2019 ◽  
Author(s):  
Piotr Kanclerz ◽  
Christoph Leisser ◽  
Andrzej Grzybowski ◽  
Paweł Lipowski

Abstract Background Cataract development is common in phakic eyes filled with silicone oil (SO), necessitating subsequent cataract removal. This study evaluated the refractive outcome in eyes filled with SO undergoing phacoemulsification cataract surgery (PCS). Methods This retrospective study evaluated patients with SO tamponade who were scheduled for PCS. Results Subjects (n=26) were followed-up for 29.5 ± 13.9 months after cataract surgery. The median spherical equivalent refraction (SER) was +5.3 D (interquartile range [IQR] +2.9 to +6.7) before PCS, and +3.4 D (IQR +2.0 to +4.4) after PCS. Within the follow-up period retinal reattachment after SO removal was achieved in 15 out of 26 eyes (57.7%). In 13 eyes assessment of refraction after SO-removal was possible, and showed a myopic shift of -4.6 D (IQR -2.9 to -7.3) in the SER. After SO removal, 5 of 13 eyes (38.5%) were within ±1.0 D of the target refraction, while 9 out of 13 eyes (69.2%) were within ±2.0 D. Conclusions The refractive outcome after PCS for eyes filled with SO is less predictable than that for normal eyes. Some of the eyes undergoing silicone oil injection may require long-term tamponade.


2021 ◽  
Vol 23 (5) ◽  
pp. 375-380
Author(s):  
Maurizio De Pellegrin ◽  
Désirée Moharamzadeh ◽  
Giacomo Placella ◽  
Vincenzo Salini

Klippel-Trenaunay syndrome is a rare congenital malformation which may be associated with macrodactyly. The main problem is the need for custom-made shoes. We describe the case of a female newborn affected by Klippel-Trenaunay syndrome, with a larger and longer right foot; the difference increased progressively and, at 5 years of age, the right foot was 50% larger and 38% longer than the left one. Due to the progression of the deformity, reduction surgery was advised to reduce the foot’s width. Resection of the second ray and 2nd cuneiform was performed. The result was excellent and there were no complications during a 10-year follow-up period with a decrease of width and length difference to 10% and 4%, respectively, in comparison to the contralateral foot. There were no gait anomalies. Abnormal foot width and length represented the main problems and guided the surgical strategy. Second ray resection was effective, without complications and with a good long-term functional outcome. Possibility of wearing fashionable conventional shoes without insoles was achieved to the patient’s satisfaction


2020 ◽  
Vol 30 (3) ◽  
pp. 409-412
Author(s):  
Murat Surucu ◽  
İlkay Erdoğan ◽  
Birgül Varan ◽  
Murat Özkan ◽  
N. Kürşad Tokel ◽  
...  

AbstractObjective:Double-chambered right ventricle is characterised by division of the outlet portion of the right ventricle by hypertrophy of the septoparietal trabeculations into two parts. We aim to report our experiences regarding the presenting symptoms of double-chambered right ventricle, long-term prognosis, including the recurrence rate and incidence of arrhythmias after surgery.Methods:We retrospectively investigated 89 consecutive patients who were diagnosed to have double-chambered right ventricle and underwent a surgical intervention from 1995 to 2016. The data obtained by echocardiography, cardiac catheterisation, and surgical findings as well as post-operative follow-up, surgical approaches, post-operative morbidity, mortality, and cardiac events were evaluated.Results:Median age at the time of diagnosis was 2 months and mean age at the time of operation was 5.3 years. Concomitant cardiac anomalies were as follows: perimembranous ventricular septal defect (78 patients), atrial septal defect (9 patients), discrete subaortic membrane (32 patients), right aortic arch (3 patients), aortic valve prolapse and/or mild aortic regurgitation (14 patients), and left superior caval vein (2 patients). The mean follow-up period was 4.86 ± 4.6 years. In these patients, mean systolic pressure gradient in the right ventricle by echocardiography before, immediately, and long-term after surgical intervention was 66.3, 11.8, and 10.4 mmHg, respectively. There were no deaths during the long-term follow-up period. Surgical reinterventions were performed for residual ventricular septal defect (2), residual pulmonary stenosis (1), and severe tricuspid insufficiency (1).Conclusion:The surgical outcomes and prognosis of double-chambered right ventricle are favourable, recurrence and fatal arrhythmias are unlikely in long-term follow-up.


Sign in / Sign up

Export Citation Format

Share Document