scholarly journals HEAT LOSS FROM HOT WATER SUPPLY LINE IN A RESIDENTIAL BUILDING

2011 ◽  
Vol 76 (669) ◽  
pp. 981-989
Author(s):  
Shuhei KONDO ◽  
Shuichi HOKOI
2015 ◽  
Vol 725-726 ◽  
pp. 1267-1272 ◽  
Author(s):  
Viktor Pukhkal ◽  
Boris Jurmanov

Experimental measurements of actual hot water consumption in residential building have been performed. It was established that distribution of hot water for domestic needs has random character and constitutes non-stationary process. It was proposed for hot water supply systems calculation to employ “rated mode of water consumption”. Rated mode is a simplified mathematical description of entire ordered collection of hourly consumptions anticipated during rated period of hot water supply system operation. Most precise description of water consumption rated mode may be obtained with coefficient of general hourly discontinuity at 98% coverage. Selection of hot water metering devices for residential house requires that operating flow rate of water meter should correspond by maximum to residential building water consumption parameters. Methods of calculation of daily water volumes passing through water meter at flow rates lower than transient flow rate value for the specified device were proposed.


2021 ◽  
Vol 7 (1) ◽  
pp. 1-6
Author(s):  
Olena Savchenko ◽  
◽  
Zenon Savchenko

Solar hot water supply systems can provide a significant part of the thermal energy needed in the residential sector. The use of solar hot water supply systems can reduce the consumption of traditional energy sources and, consequently, reduce greenhouse gas emissions. The aim of this article is to assess the operation of the solar heating system operation to provide the needs of the hot water supply system of a residential building with thermal energy. The efficiency of a flat solar collector operating in a single-circuit thermosyphon system of solar heating of a residential building in Lviv has been established. The solar fraction of the hot water supply system of a residential building is determined depending on the volume of hot water consumed, in particular 50, 60, 70, 80, 90, 100 l/day. It is established that the lower the need for hot water, the greater the solar fraction of the solar hot water supply system. Thus, the average annual solar fraction of the solar hot water supply system with a daily consumption of 50 l/day is 0.77, and with a daily consumption of 100 l/day the solar fraction is 0.39. The average value of the solar fraction for the solar hot water supply systems of the studied house is 0.55.


Sign in / Sign up

Export Citation Format

Share Document