scholarly journals Single-piece all-solid-state Co(II) ion-selective electrode for cobalt monitoring in real samples

2019 ◽  
Vol 1 (34) ◽  
pp. 17-24
Author(s):  
Cecylia Wardak ◽  
Małgorzata Grabarczyk
1995 ◽  
Vol 67 (20) ◽  
pp. 3819-3823 ◽  
Author(s):  
Johan. Bobacka ◽  
Tom. Lindfors ◽  
Mary. McCarrick ◽  
Ari. Ivaska ◽  
Andrzej. Lewenstam

Biosensors ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 109
Author(s):  
Li-Da Chen ◽  
Wei-Jhen Wang ◽  
Gou-Jen Wang

This study aimed to develop simple electrochemical electrodes for the fast detection of chloride, sodium and potassium ions in human serum. A flat thin-film gold electrode was used as the detection electrode for chloride ions; a single-piece type membrane based solid-state ion-selective electrode (ISE), which was formed by covering a flat thin-film gold electrode with a mixture of 7,7,8,8-tetracyanoquinodimethane (TCNQ) and ion-selective membrane (ISM), was developed for sodium and potassium ions detection. Through cyclic voltammetry (CV) and square-wave voltammetry (SWV), the detection data can be obtained within two minutes. The linear detection ranges in the standard samples of chloride, sodium, and potassium ions were 25–200 mM, 50–200 mM, and 2–10 mM, with the average relative standard deviation (RSD) of 0.79%, 1.65%, and 0.47% and the average recovery rates of 101%, 100% and 96%, respectively. Interference experiments with Na+, K+, Cl−, Ca2+, and Mg2+ ions demonstrated that the proposed detection electrodes have good selectivity. Moreover, the proposed detection electrodes have characteristics such as the ability to be prepared under relatively simple process conditions, excellent detection sensitivity, and low RSD, and the detection linear range is suitable for the Cl−, Na+ and K+ concentrations in human serum.


Water ◽  
2021 ◽  
Vol 13 (20) ◽  
pp. 2869
Author(s):  
Cecylia Wardak ◽  
Karolina Pietrzak ◽  
Małgorzata Grabarczyk

A new copper sensitive all solid-state ion-selective electrode was prepared using multiwalled carbon nanotubes-ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) nanocomposite as an additional membrane component. The effect of nanocomposite content in the membrane on the electrode parameters was investigated. The study compares, among others, detection limits, sensitivity, and the linearity ranges of calibration curves. Content 6 wt.% was considered optimal for obtaining an electrode with a Nernstian response of 29.8 mV/decade. An electrode with an optimal nanocomposite content in the membrane showed a lower limit of detection, a wider linear range and pH range, as well as better selectivity and potential stability compared to the unmodified electrode. It was successfully applied for copper determination in real water samples.


1971 ◽  
Vol 54 (4) ◽  
pp. 760-763
Author(s):  
William L Hoover ◽  
James R Melton ◽  
Peggy A Howard

Abstract A method for determining low levels of iodide in feeds and plants is proposed. The samples are mixed with a 10% phosphate solution to maintain relatively constant ionic strength and pH and analyzed with a solid-state iodide electrode. Ashing is not required and there are no significant interferences by ions commonly found in feeds. The method is accurate in determining iodide content ranging from 10.0 ppm to high concentrations. Necessary conditions for storing and cleaning the electrodes are described. The proposed method is rapid and results compare favorably with AOAC method 7.091.


Sign in / Sign up

Export Citation Format

Share Document