scholarly journals ESTIMASI DOSIS RADIASI PERMUKAAN KULIT PADA PEMERIKSAAN RADIOLOGI DENGAN APLIKASI AHD RAD BERBASIS WEB

Author(s):  
Sudibyo Dwi Saputro ◽  
Arif Fahmi ◽  
I Wayan Ari Makmur ◽  
Nurul Qomariyah

ABSTRAKDosis radiasi Sinar-X pada pemeriksaan radiologi dihitung berdasarkan dosis permukaan kulit yang diterima pasien. Hal tersebut dilakukan sebagai evaluasi terhadap pemberian dosis radiasi. Penelitian ini bertujuan untuk mengembangkan sistem aplikasi berbasis web dalam menghitung estimasi dosis radiasi permukaan kulit pasien yang diberi nama AHD Rad. Metode penelitian dilakukan dengan desain rancangan pengembangan, dan pengambilan data berupa nilai faktor eksposi. Dilakukan uji komparasi dosis radiasi antara AHD Rad dan software CALDose_X versi 5.0. Perhitungan dosis radiasi pada AHD Rad menggunakan pendekatan matematis dan fisika merujuk kepada Technical Report Series International Atomic Energy Agency (TRS IAEA) 457 tahun 2007. Data nilai faktor eksposi dengan parameter tegangan tabung (kV), arus tabung (mAs) dan jarak tabung ke film (FFD) yang sama, di masukkan melalui aplikasi CALDose_X versi 5.0 dan AHD Rad. Jumlah data sebanyak 50 dengan pengambilan data secara random sampling pada pemeriksaan radiografi umum. Pengolahan data menggunaan SPSS 11. Uji komparasi dilakukan dengan margin error 5 % dengan tingkat kepercayaan 95 %. Hasil menunjukkan nilai tidak terdapat perbedaan signifikan pada uji komparasi yang dilakukan pada aplikasi AHD Rad dengan CALDose_X versi 5.0. Sehingga aplikasi AHD Rad dapat dipergunakan dalam estimasi dosis radiasi pasien. .Kata kunci: Dosimetri; Dosis Radiasi Permukaan Kulit; AHD Rad ABSTRACTX-ray radiation dose in a radiological examination is calculated based on the skin surface dose received by the patient. This is done as an evaluation of the radiation dose. This study aims to develop a web-based application system for calculating the estimated dose of radiation to the patient's skin surface, which is named AHD Rad. The research method was carried out with a development design and data collection in exposure factor values. A comparative test of radiation dose was conducted between AHD Rad and CALDose_X software version 5.0. Calculation of radiation dose on AHD Rad using mathematical and physical approaches refers to the Technical Report Series International Atomic Energy Agency (TRS IAEA) 457 in 2007. Exposure factor value data with tube voltage parameters (kV), tube current (mAs), and tube distance to film (FFD), entered through the CALDose_X application version 5.0 and AHD Rad. The number of data is 50 by taking data by random sampling on general radiographic examination. Data processing using SPSS 11. The comparison test was carried out with a margin of error of 5% with a 95% confidence level. The results show no significant difference in the comparison test carried out on the AHD Rad application with CALDose_X version 5.0 so that the AHD Rad application can be used to estimate the patient's radiation dose. Keywords: Dosimetry; Skin Surface Radiation Dose; AHD Rad.

2017 ◽  
Vol 19 (2) ◽  
pp. 103
Author(s):  
I Putu Susila ◽  
Arif Yuniarto

Radiation dose assessment to determine the potential of radiological impacts of various installations within nuclear facility complex is necessary to ensure evironmental and public safety. A simple generic model-based method for calculating radiation doses caused by the release of radioactive substances into the environment has been published by the International Atomic Energy Agency (IAEA) as the Safety Report Series No. 19 (SRS-19). In order to assist the application of the assessment method and a basis for the development of more complex assessment methods, an open-source based software code has been designed and implemented. The software comes with maps and is very easy to be used because assessment scenarios can be done through diagrams. Software verification was performed by comparing its result to SRS-19 and CROM software calculation results. Dose estimated by SRS-19 are higher compared to the result of developed software. However, these are still acceptable since dose estimation in SRS-19 is based on conservative approach. On the other hand, compared to CROM software, the same results for three scenarios and a non-significant difference of 2.25% in another scenario were obtained. These results indicate the correctness of our implementation and implies that the developed software is ready for use in real scenario. In the future, the addition of various features and development of new model need to be done to improve the capability of software that has been developed.Keywords: Radiation dose assessment, software code, radioactive discharge, environment, IAEA SRS-19. PERANCANGAN, IMPLEMENTASI DAN VERIFIKASI PERANGKAT LUNAK UNTUK KAJIAN DOSIS RADIASI BERBASIS MODEL LINGKUNGAN GENERIK SEDERHANA. Kajian dosis radiasi untuk mengetahui potensi dampak radiologi akibat pengoperasian berbagai instalasi yang ada di dalam kawasan instalasi nuklir sangat diperlukan untuk menjamin keselamatan masyarakat dan lingkungan. Metode sederhana berbasis model lingkungan generik untuk menghitung dosis radiasi yang disebabkan oleh pelepasan zat radioaktif ke lingkungan telah diterbitkan oleh International Atomic Energy Agency (IAEA) sebagai Safety Report Series No. 19 (SRS-19). Untuk lebih memudahkan penerapan metode tersebut, maupun sebagai dasar kajian serta pengembangan metode yang lebih kompleks, maka dilakukan perancangan dan implementasi perangkat lunak terkait berbasis open-source. Perangkat lunak yang dibuat telah dilengkapi dengan peta serta sangat mudah digunakan karena skenario kajian dosis radiasi dapat dibuat melalui diagram. Verifikasi melalui komparasi dengan nilai hasil perhitungan di SRS-19 serta hasil perhitungan perangkat lunak CROM. Hasil komparasi dengan SRS-19 menunjukkan adanya perbedaan pada empat skenario yang diuji. Hal ini wajar karena pada SRS-19 perhitungan dilakukan dengan pendekatan konservatif sehingga nilai dosis yang dihasilkan lebih besar jika dibandingkan dengan perangkat lunak yang dikembangkan. Selanjutnya, pada komparasi dengan perangkat lunak CROM, keduanya menunjukkan hasil yang sama pada tiga skenario serta perbedaan yang tidak siginifikan yaitu sebesar 2,25% pada satu skenario. Hasil tersebut menunjukkan bahwa implementasi perangkat lunak telah berhasil dan perangkat lunak tersebut dapat digunakan untuk kajian yang nyata. Kedepannya, penambahan berbagai fitur serta pengembangan model kajian perlu dilakukan untuk meningkatkan kemampuan perangkat lunak yang telah dibuat. Kata kunci: Kajian dosis radiasi, perangkat lunak, lepasan zat radioaktif, lingkungan, IAEA SRS-19


Sign in / Sign up

Export Citation Format

Share Document