scholarly journals Method of assessing the reduction of solar heat on window surface shaded by continuous vertically slanted shading devices

Author(s):  
Tran Ngoc Chan ◽  
Pham Thi Hai Ha ◽  
Pham Van Luong ◽  
Nguyen Thi Khanh Phuong

The research discusses calibration of the method used to calculate solar heat transfer through shaded windows with continuous vertical slanted shading devices (below is abbreviated as "vertical slanted fins") with any slant angle Θ through a radiation reduction coefficient - Kbt. In order to evaluate the reduction of solar heat on window surface shaded by shading devices, a designated coefficient β of solar heat gain reduction through glazed windows should be established. It is the ratio of the transmitted amount of solar heat (including direct and diffuse radiation) through windows with shading device QK to those without solar shading device QKo. The study also introduces two in-house software programs. These programs help calculating solar heat gain and coefficient β for vertically slanted fins with any slant angle θ for 16 window orientations. The results of this study will be applied to the implementation of the Vietnamese national code QCVN 09:2017/BXD towards energy efficiency in buildings.

2017 ◽  
Vol 10 (2) ◽  
pp. 64 ◽  
Author(s):  
Bokyoung Koo ◽  
Keonho Lee ◽  
Youngsub An ◽  
Kyudong Lee

2017 ◽  
Vol 10 (6) ◽  
pp. 1553-1571 ◽  
Author(s):  
Ayelén Villalba ◽  
Erica Correa ◽  
Andrea Pattini ◽  
Daniel Vicare

1965 ◽  
Vol 8 (4) ◽  
pp. 0470-0472
Author(s):  
L. W. Neubauer and R. D. Cramer

Vestnik MGSU ◽  
2021 ◽  
pp. 655-665
Author(s):  
Chan Ngoc Tran ◽  
Nguyen Thi Khanh Phuong ◽  
Ekaterina V. Gorbarenko

Introduction. The article proposes a new energy efficiency assessment method based on a new technique used to calculate the window heat gain. The proposed method takes account of the coefficient of irradiance reduction by the sun shading device. The study was carried out for the shading device of the egg-crate type. Materials and methods. Calculations are based on the projection of a sunbeam performed for a fraction of a window area in the shade. They take account of the coefficient of irradiance reduction applied due to the presence of the sun shading device. A shading device reduces the irradiance, caused by diffused solar radiation, and coefficient Kbt is applied to demonstrate this process. This coefficient was identified in an experiment and expressed in the form of regression equations. To evaluate the energy efficiency with regard for the effectiveness of shading devices, coefficient of solar radiation gain reduction β was developed. This coefficient is described by the ratio of the value of solar radiation incoming through a glazed window in the presence of shading device QK to the value of solar radiation incoming through a glazed window that has no shading QKo. The software programme was used to verify the calculations of the heat gain from the solar radiation incoming through the window system with regard for the shading device in various geographical regions in summer (in Hanoi and Moscow). Results. The results, obtained using the proposed methodology and the observation data, show an insignificant difference in the relative value of β; and they demonstrate a major error when qwindow, or the absolute value of heat entering the room, is taken account of. The heat load, incoming through the window system, is down by 42–45 % in Moscow and by 45–53 % in Hanoi in the hottest period of the year if shading devices are used. Conclusions. The proposed methodology and computer software, used for a quick assessment of the energy efficiency of a window system equipped with shading devices, allow to design building envelopes that feature high energy efficiency in terms of air conditioning systems, given that coefficient of radiation gain reduction β is taken account of.


2020 ◽  
Vol 26 (64) ◽  
pp. 1001-1006
Author(s):  
Keiichiro TANIGUCHI ◽  
Masayuki MAE ◽  
Siyu JI ◽  
Kozo TAKASE ◽  
Teruki KOJIMA ◽  
...  

2019 ◽  
pp. 164-184
Author(s):  
Dayan de Loyola R. Garcia ◽  
Fernando Oscar R. Pereira

Daylight glare arouses buildings’ occupants to insert internal shading devices. When solving glare issues, shading strategies can increase internal temperature and building cooling energy consumption, especially in hot climates. Indoor environmental quality has been treated through architectural and engineering projects utilising spatial-temporal metrics and controls algorithms. This article focused on investigating some interactions between user behaviour, shading devices proprieties, and their effects on building’s luminous and thermal environment. This research aimed to relate daylight glare probability’s reductions through internal shading devices uses, with their effects on the window’s solar heat gain and energy cooling demand. Using building modelling and simulation approach through Rhinoceros 3D 5.0 and plug-ins Grasshopper+DIVA, Daylight Glare Probability (DGP) hourly values were generated for an occupant, 1.5 m away from the window at a side lit-room. The open-access model is a typical private office in the multi-floors building. Window’s solar heat gains and energy cooling demands were recorded using EnergyPlus 8.4 software. The model was simulated in East, West, North and South orientations, at Florianópolis. Subtropical Brazilian city. Starting from ‘without solar control’ cases, 8 controls were applied to 4 internal shading devices: blinds 50°, blinds 0°, curtains and roller shades. Clearer and darker colours were considered by two proprieties sets. From two fixed obstruction modes (100% and 50%), DGPintolerable (>45%) and direct solar radiation (>50W/m²) were applied to proposed monthly, daily and automatic controls. DGPintolerable annual frequencies at uncontrolled condition varied from 30% to 65%. These differences pointed out design guidelines according to façades. It has been confirmed that 0° blinds don’t secure daylight glare and increase energy cooling demand. Dark roller shades, curtains and blinds 50° completely solved glare problems, controlled by ‘always 100% closed’ mode and DGPintolerable based controls. Clear devices still allowed 2% of DGPintolerable frequency. However, clear roller shades contributed to reducing annual cooling demand until 11.5% while other devices achieved until 52% increase. Dark curtains indicated maximum increased in annual window’s solar heat gain (3%). Obtained results allowed identifying some design guidelines to balance daylight glare protection and energy-efficiency, contributing to sustainable building design and low impact architecture.


2020 ◽  
Vol 38 (3A) ◽  
pp. 402-411
Author(s):  
Mohannad R. Ghanim ◽  
Sabah T. Ahmed

Double skin ventilated roof is one of the important passive cooling techniques to reduce solar heat gain through roofs. In this research, an experimental study was performed to investigate the thermal behaviour of a double skin roof model. The model was made of two parallel galvanized steel plates. Galvanized steel has been used in the roof construction of industrial buildings and storehouses in Iraq. The effect of inclination angle (ϴ) from the horizontal and the spacing (S) between the plates was investigated at different radiation intensities. It is found that using a double skin roof arrangement with a sufficient air gap (S) can reduce the heat gain significantly. The higher the inclination angle (ϴ) the higher the ventilation rate, the lower the heat gain through the roof. In this study, increasing the air gap from 2 cm to 4 cm reduced the heat gain significantly but when the gap was further increased to 6 cm, the reduction in the heat flux was insignificant. A dimensionless correlation was also reduced between Nusselt number () and the single parameter  where L is the channel length. This correlation can be handily utilized for designing of engineering applications dealing with high temperature difference natural convection heat transfer.


Sign in / Sign up

Export Citation Format

Share Document