insulation performance
Recently Published Documents


TOTAL DOCUMENTS

794
(FIVE YEARS 326)

H-INDEX

23
(FIVE YEARS 8)

2022 ◽  
Vol 9 ◽  
Author(s):  
Yunzhu An ◽  
Menghan Su ◽  
Yuanchao Hu ◽  
Shangmao Hu ◽  
Tao Huang ◽  
...  

The environmental conditions affect the external insulation performance of power equipment. In order to study the physical characteristics of air discharge, the microscopic process of electron–molecule collision in the air based on the Boltzmann equation has been studied in this paper. The influence of humidity on the air gap insulation performance was also analyzed. The calculation results show that with the temperature 300 K and the pressure 1.0 atm, the electron energy distribution function and electron transport parameters varied with the air relative humidity. As the air relative humidity is increased by each 30%, the average electron energy decreases by about 0.2 eV, the reduced electron mobility decreases by about 0.25 × 1023 [1/(V·m·s)], the reduced electron diffusion coefficient decreases by about 0.2 × 1024 [1/(m s)], and the effective ionization coefficient decreases by about 4 × 10−24 m2. As the air relative humidity increases from 0% to 60%, the critical breakdown electric field increases by 1.22 kV/cm.


2021 ◽  
Vol 21 (6) ◽  
pp. 125-131
Author(s):  
Jeachun Sa ◽  
Youngkyu Kown ◽  
Jaemoon Lee ◽  
Sehong Min

During a fire, the major cause of casualties is the toxic gas produced from combustible interior and exterior materials. Increasing the time for occupant evacuation by reducing toxic gas is the most effective way of reducing casualties. Many casualties occurred in recent fires at the Jecheon Sports Center, Miryang Sejong Hospital, and Icheon Distribution Center. The commonality is that the toxic gas produced from combustible interior and exterior materials was the major cause of the casualties. In this study, phenol foam insulation material was considered as an alternative pipe lagging material, owing to its limited combustibility and non-production of toxic gas, to determine a method for removing the toxic gas generated from the combustion of pipe lagging material. Phenol foam insulation material is often used as the insulation material for building exteriors owing to its excellent insulation performance. Moreover, it has the advantage of being an environment-friendly product with zero ozone layer destruction coefficient and low harmful substance emissions. The incombustibility of phenol foam insulation material was verified through the Standard Performance Test of the Limited Combustible Material (Ministry of Land, Infrastructure and Transport Notice No. 2020-1053). Further, an alternative is to be proposed if a pipe lagging material with inadequate incombustibility is used in the site even though a tested pipe lagging material with limited combustibility is available.


Coatings ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 25
Author(s):  
Li Shi ◽  
Yuanfeng Lu ◽  
Hanze Huang

Hot streaks and rotor–stator interaction have a great influence on the aerothermal performance of turbine blades. Previous investigations have conducted limited study of the film-cooled blade. To investigate the combined effects of a hot streak and rotor–stator interaction on the coated blade, an unsteady numerical simulation has been conducted with an efficient unsteady Navier–Stokes solver in this paper. The numerical results at four different relative stator–rotor locations (t = 0/4 T, 1/4 T, 2/4 T, and 3/4 T) have been investigated in one stator period. Compared with the stator, rotor–stator interaction exerts a significant impact on the cooling performance of the rotor blade under hot streak inlet conditions. The overall cooling effectiveness distribution of the coated rotor blade is similar to that of the uncoated blades in one stator period. Relatively lower overall cooling performance of the rotor blade can be observed in the 1/4 stator period. Then, the cooling performance begins to increase and relatively larger cooling effectiveness can be observed in the 3/4 stator period. The addition of a TBC is generally beneficial to the improvement of blade surface cooling performance, especially for the areas with low overall cooling performance. However, a negative cooling effectiveness increment can be observed at the trailing edge. It shows that for an area with poor cooling performance, the addition of thermal barrier coating will have the opposite effect. Therefore, it is necessary to enhance the design of cooling arrangements at the trailing edge to maximize the insulation performance of TBCs for the coated rotor blade.


Gels ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 17
Author(s):  
Qiqi Song ◽  
Changqing Miao ◽  
Huazheng Sai ◽  
Jie Gu ◽  
Meijuan Wang ◽  
...  

Forming fibers for fabric insulation is difficult using aerogels, which have excellent thermal insulation performance but poor mechanical properties. A previous study proposed a novel method that could effectively improve the mechanical properties of aerogels and make them into fibers for use in fabric insulation. In this study, composite aerogel fibers (CAFs) with excellent mechanical properties and thermal insulation performance were prepared using a streamlined method. The wet bacterial cellulose (BC) matrix without freeze-drying directly was immersed in an inorganic precursor (silicate) solution, followed by initiating in situ sol-gel reaction under the action of acidic catalyst after secondary shaping. Finally, after surface modification and ambient drying of the wet composite gel, CAFs were obtained. The CAFs prepared by the simplified method still had favorable mechanical properties (tensile strength of 4.5 MPa) and excellent thermal insulation properties under extreme conditions (220 °C and −60 °C). In particular, compared with previous work, the presented CAFs preparation process is simpler and more environmentally friendly. In addition, the experimental costs were reduced. Furthermore, the obtained CAFs had high specific surface area (671.3 m²/g), excellent hydrophobicity, and low density (≤0.154 g/cm3). This streamlined method was proposed to prepare aerogel fibers with excellent performance to meet the requirements of wearable applications.


2021 ◽  
Author(s):  
Takao Katsura

New, low-cost transparent vacuum insulation panels (TVIPs) using structured cores for the windows of existing buildings are proposed. The TVIP is produced by inserting the structured core, the low-emissivity film, and the adsorbent into the transparent gas barrier envelopes. In this chapter, the authors introduce the outlines, the design and thermal analysis method, the performance evaluation (test) method. Firstly, five spacers, namely peek, modified peek, mesh, silica aerogel, and frame, are selected as the structured core. The effective thermal conductivity of TVIPs with five different spacers is evaluated at different pressure levels by applying numerical calculation. The result indicated that TVIPs with frame and mesh spacers accomplish better insulation performance, with a center-of-panel apparent thermal conductivity of 7.0 × 10−3 W/m K at a pressure of 1 Pa. The apparent thermal conductivity is the same as the value obtained by the simultaneous evacuation thermal conductivity measurement applying the heat flux meter method. Furthermore, using a frame-type TVIP with a total thickness of 3 mm attached to an existing window as a curtain decreases the space heat loss by approximately 69.5%, whereas the light transparency decreases to 75%.


Gels ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 7
Author(s):  
Chayanan Boonrawd ◽  
Supan Yodyingyong ◽  
Lazhar Benyahia ◽  
Darapond Triampo

In this work, the novel natural rubber latex (NRL) mixing was approached. The mixing process was carried out by using n-hexane as the dispersed phase of silica aerogel which acted as thermal insulation filler prior to NRL mixing. The silica aerogel/NR composites were prepared with different silica aerogel contents of 20, 40, 60, 80, and 100 parts per hundred rubber (phr). The morphology of the 40 phr composite showed the NR macropore formation with silica aerogel intercalated layers. The optimal content of silica aerogels and n-hexane were the key to obtaining the NR macropore. The thermal insulation performance of silica aerogel/NR composites was investigated because of their porous structures. The thermal conductivity of the composites were lower than that of the neat NR sheet and decreased from 0.081 to 0.055 W m−1·K−1 with increasing silica aerogel content. The lower densities of the composites than that of the NR sheet were revealed noticeably. In addition, the silica aerogel/NR composites exhibited a higher heat retardant ability than that of the NR sheet, and the comparable glass transition temperatures (Tg) of the composites and the neat NR indicated the maintained flexibility at ambient temperature or higher, which can benefit various temperature applications. The overall results demonstrated that the silica aerogel/NR composites from the novel NRL mixing preparation could be a promising technique to develop the porous materials and be utilised as thermal insulation products and building constructions.


Sign in / Sign up

Export Citation Format

Share Document