scholarly journals Analisis Perubahan kV dan mAs terhadap Kualitas Gambar dan Dosis Radiasi pada Pemeriksaan Multislice Computed Tomography Abdomen dalam Kasus Tumor Abdomen di Instalasi Radiologi RSUD dr. Saiful Anwar Malang

2016 ◽  
Vol 2 (1) ◽  
pp. 129-133
Author(s):  
Ardi Soesilo Wibowo ◽  
Gatot Murti Wibowo ◽  
Anang Prabowo

Backgroud: Examination of the abdomen CT scan is often done by using standard protocol, meanwhile the actual parameter can be modified according to local needs considering image quality and radiation dose based on Karabulut and Ariyuek (2016). Abdomen CT Scan by GE 16 slices unit in Radiology Instaallation of Dr. Saiful Anwar Malang Hospital, using exposure factor of 120 kV, 234 mAs and the value of the CTDI dose was 53.04 mGy. While the BAPETEN’s reference of CTDI value, a CT scan of abdomen was 25 mGy.  This study aims to determine the changes of the value of kV and mAs to the image quality and the radiaton dose in the abdomen MSCT examination on abdominal tumor case in Radiology Installation of Dr. Saiful Anwar Malang Hospital.Methods: This research was a quantitative research with an experimental approach. The data were collected from three variations of tube voltage (kV) ie 100 kV, 120 kV and 140 kV and three variations of tube current value and time (mAs) ie, 180 mAs, 195 mAs, and 210 mAs. Radiographs was evaluated by three radiology physicians. Data were analyzed by scoring method of respondent’s assessment to assess MSCT image quality of abdominal tumor, while the radiation dose was obtained by CTDI recording.Results: The results showed that there was influence of tube voltage variation to image quality of abdominal tumor using MSCT unit. The higher kV used, the higher image quality resulted. From the calculation of the percentage from the assessment, the highest score of variation was at 140 kV, while the lowest score of variation was at 100 kV. Based on the recording CTDI radiation dose on the monitor, found that the higher value of kV, the higher radiation resulted. The mAs variations influenced the image quality of abdominal tumor using MSCT unit. Acoording to the percentage of the assessment, the highest score of variation found in 210 mAs, and the lowest score of variation found in 180 mAs. Based on the recording of radiation dose on the monitor, the higher mAs value, the higher radiation dose using MSCT unit. It was recommended to use 195 kV and 120 mAs for MSCT examination of abdominal tumor in Radiology Installation of Dr. Saiful Anwar Malang Hospital.Conclusion: There was influence of kV and mAs variation to anatomical image clarity and radiation dose of abdomen MSCT examination

Author(s):  
Halinda Fatmayanti ◽  
Kusworo Adi ◽  
Yeti Kartikasari

Background: Thorax MSCT examination is a diagnostic imaging that is capable of displaying both normal and pathological lung and respiratory organs. MSCT examination also has a better level of sensitivity and specificity compared to other modalities, but the radiation exposure given is very high, so the radiation dose given to patients is high. The reduction in radiation dose is very important because of the direct exposure to sensitive tissue. One method of reducing radiation dose is by reducing the tube voltage. However, the decrease in tube voltage causes a decrease in image quality as indicated by increased noise and decreased CNR. To maintain the quality of the image at low tube voltage setting, an IR reconstruction of SAFIRE was used. The purpose of this research is to know the impact of using SAFIRE on dose radiation and image quality of thorax MSCT.Methods: This study was an experimental study with a quasi-experimental study design. The object used was the N-1 Lungman chest phantom in which an artificial tumor was attached. Radiation dose assessment used CTDI value, while image quality assessment used noise and CNR. Data processing was conducted using linear regression test.Results: There was an effect of tube voltage setting and SAFIRE setting on radiation dose and image quality.Conclusions: Tube voltage ssetting and SAFIRE setting had an effect on radiation dose and image quality. Tube voltage setting and SAFIRE strength level setting that were able to provide optimal radiation dose and image quality were tube voltage of 80 kVp and SAFIRE strength levels 3 and 4 (S3 and S4). 


2014 ◽  
Vol 41 (9) ◽  
pp. 092505 ◽  
Author(s):  
Ching-Ching Yang ◽  
Shu-Hsin Liu ◽  
Greta S. P. Mok ◽  
Tung-Hsin Wu

2015 ◽  
Vol 57 (6) ◽  
pp. 645-651 ◽  
Author(s):  
Jan-Erik Scholtz ◽  
Moritz Kaup ◽  
Johannes Kraft ◽  
Eva-Maria Nöske ◽  
Friedrich Scheerer ◽  
...  

Author(s):  
Michael Esser ◽  
Sabine Hess ◽  
Matthias Teufel ◽  
Mareen Kraus ◽  
Sven Schneeweiß ◽  
...  

Purpose To analyze possible influencing factors on radiation exposure in pediatric chest CT using different approaches for radiation dose optimization and to determine major indicators for dose development. Materials and Methods In this retrospective study at a clinic with maximum care facilities including pediatric radiology, 1695 chest CT examinations in 768 patients (median age: 10 years; range: 2 days to 17.9 years) were analyzed. Volume CT dose indices, effective dose, size-specific dose estimate, automatic dose modulation (AEC), and high-pitch protocols (pitch ≥ 3.0) were evaluated by univariate analysis. The image quality of low-dose examinations was compared to higher dose protocols by non-inferiority testing. Results Median dose-specific values annually decreased by an average of 12 %. High-pitch mode (n = 414) resulted in lower dose parameters (p < 0.001). In unenhanced CT, AEC delivered higher dose values compared to scans with fixed parameters (p < 0.001). In contrast-enhanced CT, the use of AEC yielded a significantly lower radiation dose only in patients older than 16 years (p = 0.04). In the age group 6 to 15 years, the values were higher (p < 0.001). The diagnostic image quality of low-dose scans was non-inferior to high-dose scans (2.18 vs. 2.14). Conclusion Radiation dose of chest CT was reduced without loss of image quality in the last decade. High-pitch scanning was an independent factor in this context. Dose reduction by AEC was limited and only relevant for patients over 16 years. Key Points Citation Format


2014 ◽  
Vol 56 (9) ◽  
pp. 797-803 ◽  
Author(s):  
Matthias S. May ◽  
Manuel R. Kramer ◽  
Achim Eller ◽  
Wolfgang Wuest ◽  
Michael Scharf ◽  
...  

1996 ◽  
Vol 23 (2) ◽  
pp. 239-240 ◽  
Author(s):  
Charles A. Kelsey ◽  
Fred A. Mettler ◽  
Lisa M. Sullivan
Keyword(s):  