scholarly journals Review Study on the Accumulation and Release of Trace Metal Elements on Aluminum Containing Sediments in Drinking Water Distribution System

2020 ◽  
Vol 2 (1) ◽  
Author(s):  
Xiaoni ZHANG ◽  
Jinghua MENG ◽  
Li CHEN ◽  
Huanhuan ZUO ◽  
Wendong WANG

Accumulation and releasing of trace metal elements on aluminum containing sediments of inner drinking water pipe is discussed, as studied from five variations effecting: raw water quality, chemical reagents, solution pH and drinking water flow condition . In order to decrease the release of trace metal elements, and to ensure the pipe operation and human safety, water quality adjustment is suggested to avoid aluminum containing sediments formation in drinking distribution system. The maximum amounts of accumulation of common trace metal elements are given. Future trends of development in this field are also proposed.

2012 ◽  
Vol 12 (5) ◽  
pp. 580-587 ◽  
Author(s):  
Stephen Mounce ◽  
John Machell ◽  
Joby Boxall

Safe, clean drinking water is a foundation of society and water quality monitoring can contribute to ensuring this. A case study application of the CANARY software to historic data from a UK drinking water distribution system is described. Sensitivity studies explored appropriate choice of algorithmic parameter settings for a baseline site, performance was evaluated with artificial events and the system then transferred to all sites. Results are presented for analysis of nine water quality sensors measuring six parameters and deployed in three connected district meter areas (DMAs), fed from a single water source (service reservoir), for a 1 year period and evaluated using comprehensive water utility records with 86% of event clusters successfully correlated to causes (spatially limited to DMA level). False negatives, defined by temporal clusters of water quality complaints in the pilot area not corresponding to detections, were only approximately 25%. It was demonstrated that the software could be configured and applied retrospectively (with potential for future near real time application) to detect various water quality event types (with a wider remit than contamination alone) for further interpretation.


Author(s):  
Valeria Mirela Brezoczki ◽  
◽  
Gabriela Maria Filip ◽  

This paper presents the analysis of the quality indicator of a subterranean raw water source, captured in Crăciunesti, Sighetu Marmatiei, followed by the description of the technological flow of capturing and chlorinating water with the aim of making it drinkable, and the analysis of the obtained values of the physical, chemical and bacteriological indicators. The period within which water quality was monitored for this paper covers four months (December 2016, March, April and May 2017). Within this period the analyses regarding water quality control were carried out by the laboratory of the Water Treatment Baia Mare. The analysis of the obtained results highlighted a series of problems regarding the existence of certain indicators/parameters with values above the legally admissible threshold with regard to water quality. The manganese found in raw water exceeds the admissible threshold by 160%, in December 2016, and by 120% in March 2017, but it is within limits during the months of April and May. The occurrence of colonies developed at 37 °C and 22°C in the raw water requires chemical treatment of the raw water aimed at disinfecting it. The parameters of drinking water correspond to the values admissible through the laws in force, the water being distributed to the consumers through the Drinking water distribution system in Sighetu Marmatiei.


Sign in / Sign up

Export Citation Format

Share Document