48. Using Carbon Dioxide as a Tracer Gas to Measure Air Change Rate in a Single Zone

2004 ◽  
Author(s):  
C. Simmons ◽  
F. Boelter ◽  
G. Crawford
2017 ◽  
Vol 115 ◽  
pp. 173-181 ◽  
Author(s):  
K.E. Anders Ohlsson ◽  
Bin Yang ◽  
Alf Ekblad ◽  
Christoffer Boman ◽  
Robin Nyström ◽  
...  

1997 ◽  
Vol 46 (4) ◽  
pp. 251-257 ◽  
Author(s):  
Masakazu HASEGAWA ◽  
Yuzuru KURABAYASHI ◽  
Toshinori ISHII ◽  
Kazuya YOSHIDA ◽  
Nobukazu UEBAYASHI ◽  
...  

Author(s):  
Minki Sung ◽  
Seongmin Jo ◽  
Sang-Eun Lee ◽  
Moran Ki ◽  
Bo Choi ◽  
...  

In this study, the results of an airflow investigation conducted on 7 June 2015 as part of a series of epidemiologic investigations at Pyeongtaek St. Mary’s Hospital, South Korea, were investigated. The study involved 38 individuals who were infected directly and indirectly with Middle East Respiratory Syndrome (MERS), by a super-spreader patient. Tracer gas experiments conducted on the eighth floor, where the initial patient was hospitalized, confirmed that the tracer gas spread to adjacent patient rooms and rooms across corridors. In particular, the experiment with an external wind direction and speed similar to those during the hospitalization of the initial patient revealed that the air change rate was 17–20 air changes per hour (ACH), with air introduced through the window in the room of the infected patient (room 8104). The tracer gas concentration of room 8110, which was the farthest room, was 7.56% of room 8104, indicating that a high concentration of gas has spread from room 8104 to rooms across the corridor. In contrast, the tracer gas was barely detected in a maternity ward to the south of room 8104, where there was no secondary infected patient. Moreover, MERS is known to spread mainly by droplets through close contact, but long-distance dispersion is probable in certain environments, such as that of a super-spreader patient hospitalized in a room without ventilation, hospitals with a central corridor type, and indoor airflow dispersion due to external wind.


2020 ◽  
Vol 5 (10) ◽  
pp. 85
Author(s):  
Ricardo M. S. F. Almeida ◽  
Eva Barreira ◽  
Pedro Moreira

The measurement of ventilation rates is crucial in understanding buildings’ performances, but can be a rather complex task due to the time-dependency of wind and buoyancy forces, which are responsible for the pressure differences that induce air movement across the envelope. Thus, assessing air change rate through one-time measurements during brief periods of time may not be a reliable indicator. In this paper, the variability in the measurement of ventilation rates using the decay technique was evaluated. To that end, two compartments of a typical single-family detached dwelling were selected as a case study and 132 tests were performed, considering two different boundary conditions (door closed and door open). This work allowed the large variability of the results to be highlighted, as the coefficient of variation ranged from 20% to 64%. Wind speed had a key effect on the results, especially because during the measurements indoor–outdoor temperature differences were not so significant. The possibility of using occupant-generated carbon dioxide as tracer gas was also analyzed, but problems of cross-contamination were identified.


Author(s):  
Sarah L. Paralovo ◽  
Maarten Spruyt ◽  
Joris Lauwers ◽  
Rudi Swinnen ◽  
Borislav Lazarov ◽  
...  

2017 ◽  
Vol 132 ◽  
pp. 831-836 ◽  
Author(s):  
Ricardo M.S.F. Almeida ◽  
Eva Barreira ◽  
Pedro Moreira

Sign in / Sign up

Export Citation Format

Share Document