scholarly journals Galvanic Corrosion Behavior between Pure Aluminum 1050 and CFRP in NaCl Solution

2015 ◽  
Vol 64 (6) ◽  
pp. 224-227
Author(s):  
Masahiro Sakai ◽  
Chinami Sakamoto
Author(s):  
Xiaoyan Wang ◽  
Lei Zhang ◽  
Xianren Kuang ◽  
Minxu Lu

Kela-2 Gas Field is the main supply for the West-East Gas Pipeline which runs across China with length of 4000 kilometers. Natural gas from Kela-2 contains CO2/H2S sour components and 10% condensation water, which makes the medium present very strong corrosivity. In avoidance of corrosion failure, DSS UNS S31803 line pipes were introduced to transmit the gas from the Gas Field to gathering center and processing factory. And it is the first time DSS pipes which is totally about 13km were widely used in oil and gas pipeline around the world. As it is known, DSS UNS S31803 pipes and traditional linepipes X80 were welded together between the gathering lines and mainline. Duplex stainless steel (DSS) UNS S31803 and X80 were welded by metal inertia gas welding (MIG) with consumable ER2209, and the joints take on good mechanical properties. The type II boundary close to the fusion boundary at the carbon steel side was observed by SEM. Obvious concentration gradient of Ni and Cr was observed in the region between the two boundaries, where the hardness was much higher. The weld metal with columnar and some polygonal ferrites take on good passivation against test solution. The heat affected zone beside the X80 base material is mostly granular bainite, some polygonal ferrites and few MA, X80 base material present obvious rolling state, the microstructure of which is the same to X80 heat affected zone, but the level of crystal size reach to 11.6. The corrosion behavior of them dosen’t have any difference, but the corrosion potential of X80 HAZ is much higher than X80 BM, about 50 mv, the corrosion rate of X80 HAZ is also much higher than X80 base material. Potential curves of different weldment regions were also studied in 3.5% NaCl solution and 3.5% NaCl solution with saturated CO2. Galvanic corrosion behavior of weld metal and X80 steel was also tested and the conclusion is: The cathode reaction is controlled by oxygen diffusion, and when area ratio S (S = Ac / Aa, Ac is the area of DSS WM, Aa is the area of X80 BM) increases, corrosion current of X80 is enhanced rapidly, which is called “gathering principle”. When the weld metal and X80 coupled, cathode has much higher polarization potential and is protected completely.


2013 ◽  
Vol 668 ◽  
pp. 808-813
Author(s):  
Jun Xiu Shi ◽  
Jian Hua Liu

The susceptibility to stress corrosion cracking (SCC) and galvanic corrosion of an aeroplane pipe made of 1Cr18Ni9Ti connected with a pipe coupling that made of Ti-Ni-Nb shape memory alloy were evaluated. SCC test was completed under simulated service environment in 6% NaCl solution through a self-designed corrosive system. Galvanic corrosion behavior of Ti-Ni-Nb/1Cr18Ni9Ti couple was conducted in 3.5% NaCl solution at 30°C, in which galvanic corrosion current (Ig) and galvanic corrosion potential (Eg) were monitored. The corrosion morphology was observed by using scanning electronic microscope (SEM) and optical microscope (OM) after SCC test and galvanic test. It was showed that no obvious corrosion was detected on the surface of the whole pipe system after the simulated test. The two metals showed excellent resistance to SCC based on the section morphology observation. The average galvanic corrosion current of 1Cr18Ni9Ti/Ti-Ni-Nb couple was 0.13µA/cm2. No obvious corrosion pitting was detected on the surface of the two alloys by OM observation. Therefore, 1Cr18Ni9Ti pipe was safely connected with Ti-Ni-Nb pipe coupling in aeroplane pipe system.


2011 ◽  
Vol 686 ◽  
pp. 146-150
Author(s):  
Ding Fei Zhang ◽  
Yu Ping Liu ◽  
Chang Guo Chen ◽  
Ya Juan Xu

In this work, the galvanic corrosion behavior of AZ31 magnesium alloy in contact with A6N01S-T5 aluminum alloy in NaCl solution was investigated by electrochemical method, the salt immersion method, SEM. And three protection techniques: (a) rubber gasket technique ,(b)organic coating technique and (c) anodizing technique were used to inhibit the galvanic corrosion. The results of open circuit potential and polarization curve method were explained the corrosion behavior of AZ31 and A6N01S-T5.It was found that AZ31 as anode was accelerated corrosion and A6N01S-T5 as cathode was also corrode in salt immersion experiment. With the increasing of immersion time, the corrosion rate of AZ31 and A6N01S-T5 was gradually decreasing. Then, the efficacy of different anti-corrosive technologies was compared. Fluorine coating technique was an effective way to protect Mg alloy and Al alloy. It was possible to guide the anti-corrosion of magnesium alloy in mobile industry.


2015 ◽  
Vol 30 (6) ◽  
pp. 627
Author(s):  
YE Zuo-Yan ◽  
LIU Dao-Xin ◽  
LI Chong-Yang ◽  
ZHANG Xiao-Hua ◽  
ZANG Xiao-Ming ◽  
...  

Author(s):  
Leonardo Augusto Luiz ◽  
Juliano de Andrade ◽  
Camila Melo Pesqueira ◽  
Irene Bida de Araújo Fernandes Siqueira ◽  
Gustavo Bavaresco Sucharski ◽  
...  

2021 ◽  
Vol 719 (2) ◽  
pp. 022092
Author(s):  
De Cheng ◽  
Chen Wen ◽  
Jingying Bai ◽  
Yeshen Qin ◽  
Baocheng Jiao

Sign in / Sign up

Export Citation Format

Share Document