scholarly journals The Effect of Intraocular Pressure-lowering Eye Drops on Myopic RetinoschisisPatients

2020 ◽  
Vol 61 (4) ◽  
pp. 341-346
Author(s):  
Jung Hwa Lee ◽  
Kyu Hwan Jang ◽  
Suchan Lee ◽  
Mingui Kong ◽  
Joon Hong Sohn
2018 ◽  
Vol 28 (6) ◽  
pp. 652-661
Author(s):  
Francisco Pérez-Bartolomé ◽  
Jose María Martínez de la Casa ◽  
Pedro Arriola-Villalobos ◽  
Cristina Fernández-Pérez ◽  
Julián García-Feijoó

Purpose: To quantify ocular light scattering in patients under treatment with intraocular pressure–lowering eye-drops. Methods: In this prospective, observational, cross-sectional case series study, 160 eyes of 160 patients with primary open angle glaucoma or primary ocular hypertension were consecutively recruited from our Glaucoma Department over 7 months. In total, 46 eyes of 46 healthy volunteers matched for age and sex served as the control group. The variables recorded in a single visit were as follows: drug and number of drops per day, treatment duration, OXFORD corneal staining grade, lower tear meniscus height as measured by spectral domain optical coherence tomography, ocular redness and non-invasive tear breakup time measured with the Oculus Keratograph 5M, ocular surface disease index questionnaire score and objective scatter index through a double-pass technique (Optical Analysis System II). Results: Objective scatter index was higher in the patient group (3.1, interquartile range = 1.8–5.47) than in the control group (1.95; interquartile range = 0.7–5; p = 0.017). In a multiple linear regression model, non-invasive tear breakup time was identified as the most influential variable on light scatter (mean ratio = −1.015; p = 0.003; 95% confidence interval = −1.025 to −1.005). No correlation with objective scatter index was observed for number of daily eye-drops, preservative concentration or treatment duration. Conclusion: Participants on anti-glaucoma medication showed a significantly higher objective scatter index than control group individuals. In the treated patient group, a lower non-invasive tear breakup time was associated with a higher objective scatter index. This suggests that lubricating eye-drops to improve tear breakup time could also improve vision quality in these patients by diminishing light scattering.


2019 ◽  
Vol 30 (4) ◽  
pp. 700-705 ◽  
Author(s):  
Alexander T Nguyen ◽  
Jessica Maslin ◽  
Robert J Noecker

Purpose: To describe our clinical experience with the efficacy and safety of micropulse transscleral cyclophotocoagulation as a treatment for glaucoma. Methods: In this retrospective case series, we reviewed the charts of 95 consecutive patients with various glaucoma subtypes who underwent micropulse transscleral cyclophotocoagulation. Patients were offered micropulse transscleral cyclophotocoagulation if they had perimetric glaucoma refractory to intraocular pressure–lowering topical medications and who were poor candidates for traditional filtering surgery. Eligible patients were treated with the Micropulse P3 device (IQ 810 Laser Systems; Iridex, Mountain View, CA, USA) at 2.0–2.5 W for a duration of 90 s per hemisphere at a 31.3% duty cycle. If a retreatment was needed, the power was increased to up to 3.0 W with other parameters remaining the same. Patients were considered successfully treated if their intraocular pressure was lowered by at least 20% compared to their baseline. The main outcome measure was post-operative intraocular pressure; secondary outcome measures included the number of adverse events and complications that occurred with treatment. Results: The glaucoma subtypes treated included primary open-angle glaucoma (n = 51), exfoliation glaucoma (n = 24), chronic angle-closure glaucoma (n = 15), and congenital/juvenile glaucoma (n = 5). The mean pre-operative intraocular pressure was 25.1 ± 5.3 mm Hg and the mean post-operative intraocular pressure at 12 months was 17.5 ± 5.1 mm Hg (p = 0.004). The mean number of intraocular pressure–lowering medications used preoperatively was 3.0 ± 1.1; the mean number of medications used at the 12-month post-operative visit was 1.4 ± 1.0 (p = 0.03). Success with one treatment was achieved in 73 (76.8%) of patients. With multiple treatments, all patients had significant intraocular pressure–lowering compared to baseline. The maximum number of treatments received by any single patient was 5. There were no instances of prolonged intraocular inflammation or long-term hypotony. Conclusion: Micropulse transscleral cyclophotocoagulation appears to be a safe and efficacious treatment for glaucoma. Given its improved safety profile compared to continuous-wave transscleral cyclophotocoagulation, it deserves consideration as a primary procedure.


2020 ◽  
Vol 3 (1) ◽  
pp. 7-13 ◽  
Author(s):  
Huiyuan Hou ◽  
Sasan Moghimi ◽  
Linda M. Zangwill ◽  
James A. Proudfoot ◽  
Tadamichi Akagi ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Hong Yang Zhang ◽  
Yong Jie Qin ◽  
Yang Fan Yang ◽  
Jian Gang Xu ◽  
Min Bin Yu

Purpose.To compare the efficacy of subthreshold and conventional selective laser trabeculoplasty (SLT) in lowering intraocular pressure (IOP) in the patients with primary open-angle glaucoma (POAG).Methods.Fifty-two eyes from fifty-two POAG patients were randomized into two groups, one group treated with subthreshold SLT using two-thirds of the conventional energy and the other one treated with the conventional energy. IOP was measured with the Goldmann tonometer and the anterior chamber inflammation was determined using laser flare meter.Results.The initial energy dosage used in subthreshold SLT group was significantly lower than the amount of the energy used in conventional SLT group (0.4±0.1 mJ versus0.6±0.1 mJ,P=0.030). The total energy dosage was also significantly lower in subthreshold SLT group compared to the other group (37.6±3.3 mJ versus51.8±5.7 mJ,P=0.036). However, the level of inflammation in aqueous humor, amount of reduction in IOP, and the success rate in controlling IOP was the same in both groups.Conclusion.The efficacy of subthreshold SLT group in reducing IOP in POAG patients is comparable to the efficacy of conventional SLT group.


Sign in / Sign up

Export Citation Format

Share Document