scholarly journals NON LINEAR CONTROL OF MULTI FED INDUCTION GENERETOR BASED OFFSHORE WIND TURBINE SYSTEM

Author(s):  
Keerthana . ◽  
Vahini . ◽  
Sahana . ◽  
Mohamed Rafi

Novel technique is used to improve the voltage ride of wind turbine system by using LVRT System. In most of the turbines sequence operation is a proper way to increase the capacity of electronic devices in PMDD wind power generation system. Direct Current Link are regulated in this system. Because it causes the ZSCC, which brings current oscillation, distortion of waveform, reduction in power, and interruption of Electromagnetic waves, and so on. This system gives a different methodology for offshore wind turbine system which are composed of the various control strategies applied to the multi- phase converter which can deal with mostly imbalanced. Apart from averagemodels of the turbine system MVF is used to compensate highly imbalance load but not affecting the static and dynamic response of the system. Based on the above topology, the schematic diagram of the proposed system is constructed. The simulated results of offshore wind turbine system will show the advantages of the proposed system and control strategies.

2021 ◽  
Vol 11 (2) ◽  
pp. 574
Author(s):  
Rundong Yan ◽  
Sarah Dunnett

In order to improve the operation and maintenance (O&M) of offshore wind turbines, a new Petri net (PN)-based offshore wind turbine maintenance model is developed in this paper to simulate the O&M activities in an offshore wind farm. With the aid of the PN model developed, three new potential wind turbine maintenance strategies are studied. They are (1) carrying out periodic maintenance of the wind turbine components at different frequencies according to their specific reliability features; (2) conducting a full inspection of the entire wind turbine system following a major repair; and (3) equipping the wind turbine with a condition monitoring system (CMS) that has powerful fault detection capability. From the research results, it is found that periodic maintenance is essential, but in order to ensure that the turbine is operated economically, this maintenance needs to be carried out at an optimal frequency. Conducting a full inspection of the entire wind turbine system following a major repair enables efficient utilisation of the maintenance resources. If periodic maintenance is performed infrequently, this measure leads to less unexpected shutdowns, lower downtime, and lower maintenance costs. It has been shown that to install the wind turbine with a CMS is helpful to relieve the burden of periodic maintenance. Moreover, the higher the quality of the CMS, the more the downtime and maintenance costs can be reduced. However, the cost of the CMS needs to be considered, as a high cost may make the operation of the offshore wind turbine uneconomical.


Author(s):  
Yougang Tang ◽  
Jun Hu ◽  
Liqin Liu

The wind resources for ocean power generation are mostly distributed in sea areas with the distance of 5–50km from coastline, whose water depth are generally over 20m. To improve ocean power output and economic benefit of offshore wind farm, it is necessary to choose floating foundation for offshore wind turbine. According to the basic data of a 600kW wind turbine with a horizontal shaft, the tower, semi-submersible foundation and mooring system are designed in the 60-meter-deep sea area. Precise finite element models of the floating wind turbine system are established, including mooring lines, floating foundation, tower and wind turbine. Dynamic responses for the floating foundation of offshore wind turbine are investigated under wave load in frequency domain.


2019 ◽  
Vol 19 (4) ◽  
pp. 1017-1031 ◽  
Author(s):  
Ying Xu ◽  
George Nikitas ◽  
Tong Zhang ◽  
Qinghua Han ◽  
Marios Chryssanthopoulos ◽  
...  

The offshore wind turbines are dynamically sensitive, whose fundamental frequency can be very close to the forcing frequencies activated by the environmental and turbine loads. Minor changes of support conditions may lead to the shift of natural frequencies, and this could be disastrous if resonance happens. To monitor the support conditions and thus to enhance the safety of offshore wind turbines, a model updating method is developed in this study. A hybrid sensing system was fabricated and set up in the laboratory to investigate the long-term dynamic behaviour of the offshore wind turbine system with monopile foundation in sandy deposits. A finite element model was constructed to simulate structural behaviours of the offshore wind turbine system. Distributed nonlinear springs and a roller boundary condition are used to model the soil–structure interaction properties. The finite element model and the test results were used to analyse the variation of the support condition of the monopile, through an finite element model updating process using estimation of distribution algorithms. The results show that the fundamental frequency of the test model increases after a period under cyclic loading, which is attributed to the compaction of the surrounding sand instead of local damage of the structure. The hybrid sensing system is reliable to detect both the acceleration and strain responses of the offshore wind turbine model and can be potentially applied to the remote monitoring of real offshore wind turbines. The estimation of distribution algorithm–based model updating technique is demonstrated to be successful for the support condition monitoring of the offshore wind turbine system, which is potentially useful for other model updating and condition monitoring applications.


2016 ◽  
Vol 2016 ◽  
pp. 1-16
Author(s):  
H. F. Wang ◽  
Y. H. Fan

The tension-leg platform (TLP) supporting structure is a good choice for floating offshore wind turbines because TLP has superior motion dynamics. This study investigates the effects of TLP spoke dimensions on the motion of a floating offshore wind turbine system (FOWT). Spoke dimension and offshore floating TLP were subjected to irregular wave and wind excitation to evaluate the motion of the FOWT. This research has been divided into two parts: (1) Five models were designed based on different spoke dimensions, and aerohydroservo-elastic coupled analyses were conducted on the models using the finite element method. (2) Considering the coupled effects of the dynamic response of a top wind turbine, a supporting-tower structure, a mooring system, and two models on a reduced scale of 1 : 80 were constructed and experimentally tested under different conditions. Numerical and experimental results demonstrate that the spoke dimensions have a significant effect on the motion of FOWT and the experimental result that spoke dimension can reduce surge platform movement to improve turbine performance.


Author(s):  
Emil Smilden ◽  
Erin E. Bachynski ◽  
Asgeir J. Sørensen

A simulation study is performed to identify the key contributors to lifetime accumulated fatigue damage in the support-structure of a 10 MW offshore wind turbine placed on a monopile foundation in 30 m water depth. The relative contributions to fatigue damage from wind loads, wave loads, and wind/wave misalignment are investigated through time-domain analysis combined with long-term variations in environmental conditions. Results show that wave loads are the dominating cause of fatigue damage in the support structure, and that environmental condtions associated with misalignment angle > 45° are insignificant with regard to the lifetime accumulated fatigue damage. Further, the results are used to investigate the potential of event-based use of control strategies developed to reduce fatigue loads through active load mitigation. Investigations show that a large reduction in lifetime accumulated fatigue damage is possible, enabling load mitigation only in certain situations, thus limiting collateral effects such as increased power fluctuations, and wear and tear of pitch actuators and drive-train components.


2019 ◽  
Vol 9 (4) ◽  
pp. 783 ◽  
Author(s):  
Silvio Simani ◽  
Paolo Castaldi

Fault diagnosis of wind turbine systems is a challenging process, especially for offshore plants, and the search for solutions motivates the research discussed in this paper. In fact, these systems must have a high degree of reliability and availability to remain functional in specified operating conditions without needing expensive maintenance works. Especially for offshore plants, a clear conflict exists between ensuring a high degree of availability and reducing costly maintenance. Therefore, this paper presents viable fault detection and isolation techniques applied to a wind turbine system. The design of the so-called fault indicator relies on an estimate of the fault using data-driven methods and effective tools for managing partial knowledge of system dynamics, as well as noise and disturbance effects. In particular, the suggested data-driven strategies exploit fuzzy systems and neural networks that are used to determine nonlinear links between measurements and faults. The selected architectures are based on nonlinear autoregressive with exogenous input prototypes, which approximate dynamic relations with arbitrary accuracy. The designed fault diagnosis schemes were verified and validated using a high-fidelity simulator that describes the normal and faulty behavior of a realistic offshore wind turbine plant. Finally, by accounting for the uncertainty and disturbance in the wind turbine simulator, a hardware-in-the-loop test rig was used to assess the proposed methods for robustness and reliability. These aspects are fundamental when the developed fault diagnosis methods are applied to real offshore wind turbines.


Sign in / Sign up

Export Citation Format

Share Document