scholarly journals Experimental and Numerical Investigation of the Internal Temperature of an Oil-Immersed Power Transformer with DOFS

2020 ◽  
Vol 10 (16) ◽  
pp. 5718 ◽  
Author(s):  
Yunpeng Liu ◽  
Xinye Li ◽  
Huan Li ◽  
Jiaxue Wang ◽  
Xiaozhou Fan

To accurately detect and monitor the internal temperature of an operating power transformer, the distributed optical fiber sensor (DOFS) was creatively applied inside an oil-immersed 35 kV transformer through high integration with the winding wire. On the former basis, the power transformer prototype with a completely global internal temperature sensing capability was successfully developed and it was also qualified for power grid operation through the ex-factory type tests. The internal spatially continuous temperature distribution of the operating transformer was then revealed through a heat-run test and the numerical simulation was also applied for further analysis. Hotspots of windings were continuously located and monitored (emerging at about 89%/90% height of low/high voltage winding), which were furtherly compared with the IEC calculation results. This new nondestructive internal sensing method shows a broad application prospect in the electrical equipment field. Also, the revelation of transformer internal distributed temperature can offer a solid reference for both researchers and field operation staff.

Symmetry ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1166
Author(s):  
Bin Liu ◽  
Jianping He ◽  
Shihai Zhang ◽  
Yinping Zhang ◽  
Jianan Yu ◽  
...  

Brillouin frequency shift (BFS) of distributed optical fiber sensor is extracted from the Brillouin gain spectrum (BGS), which is often characterized by Lorenz type. However, in the case of complex stress and optical fiber self damage, the BGS will deviate from Lorenz type and be asymmetric, which leads to the extraction error of BFS. In order to enhance the extraction accuracy of BFS, the Lorenz local single peak fitting algorithm was developed to fit the Brillouin gain spectrum curve, which can make the BSG symmetrical with respect to the Brillouin center frequency shift. One temperature test of a fiber-reinforced polymer (FRP) packaged sensor whose BSG curve is asymmetric was conducted to verify the idea. The results show that the local region curve of BSG processed by the developed algorithm has good symmetry, and the temperature measurement accuracy obtained by the developed algorithm is higher than that directly measured by demodulation equipment. Comparison with the reference temperature, the relative measurement error measured by the developed algorithm and BOTDA are within 4% and 8%, respectively.


2010 ◽  
Author(s):  
C. Perrotton ◽  
M. Slaman ◽  
N. Javahiraly ◽  
H. Schreuders ◽  
B. Dam ◽  
...  

2010 ◽  
Vol 37 (6) ◽  
pp. 1501-1504
Author(s):  
高存孝 Gao Cunxiao ◽  
朱少岚 Zhu Shaolan ◽  
冯莉 Feng Li ◽  
宋志远 Song Zhiyuan ◽  
曹宗英 Cao Zongying ◽  
...  

2019 ◽  
Vol 46 (4) ◽  
pp. 0410001 ◽  
Author(s):  
章征林 Zhang Zhenglin ◽  
高磊 Gao Lei ◽  
孙阳阳 Sun Yangyang ◽  
张清华 Zhang Qinghua ◽  
曾鹏 Zeng Peng

Sign in / Sign up

Export Citation Format

Share Document