scholarly journals Design of a Modular Plantar Orthosis System through the Application of TRIZ Methodology Tools

2021 ◽  
Vol 11 (5) ◽  
pp. 2051
Author(s):  
Lidia Yolanda Ramírez-Rios ◽  
Claudia Camargo-Wilson ◽  
Jesús Everardo Olguín-Tiznado ◽  
Juan Andrés López-Barreras ◽  
Everardo Inzunza-González ◽  
...  

Innovations within the medical device sector are constantly and rapidly emerging due to increasing demand, especially for orthosis systems, which usually constitute built rigids with low comfort, due mainly to the standardized production process. This article reports the design process of a plantar orthosis system from the application of Theory of Inventive Problem Solving (TRIZ) tools, known as generic parameters, matrix of contradictions, and inventive principles. The final orthosis is integrated by four modules or components (1 central and 3 movables) and customers can buy only the required ones, reducing cost in unnecessary parts. The plantar orthosis was defined based on three engineering parameters that delimited the design work by developing a customizable system that is capable of performing simultaneous functions and whose manufacture could be standardized. We identified the existence of a technical contradiction between the engineering parameters, customization, and standardization, which was solved by the inventive principles of segmentation, inversion, transition to a new dimension, and porous materials. A modular design with four components was accomplished, molds are built for each component in a machining center and injected using granulated ethylene vinyl acetate copolymer. The positions of the movable components are configured through a bolt-hole assembly mechanism to the central component, which is a flat perforated plantar base. The novelty in the design here presented is elated to supports that constitute the orthosis, which are interchangeable and adjustable to the pathological and morphological needs of each patient.

Sensors ◽  
2018 ◽  
Vol 18 (12) ◽  
pp. 4361
Author(s):  
Tinkara Mastnak ◽  
Aleksandra Lobnik ◽  
Gerhard Mohr ◽  
Matjaž Finšgar

The article presents naked-eye methods for fast, sensitive, and selective detection of isopentylamine and cadaverine vapours based on 4-N,N-dioctylamino-4′-dicyanovinylazobenzene (CR-528) and 4-N,N-dioctylamino-2′-nitro-4′-dicyanovinylazobenzene (CR-555) dyes immobilized in ethylene-vinyl acetate copolymer (EVA). The reaction of CR-528/EVA and CR-555/EVA indicator layers with isopentylamine vapours caused a vivid colour change from pink/purple to yellow/orange-yellow. Additionally, CR-555/EVA showed colour changes upon exposure to cadaverine. The colour changes were analysed by ultraviolet–visible (UV/VIS) molecular absorption spectroscopy for amine quantification, and the method was partially validated for the detection limit, sensitivity, and linear concentration range. The lowest detection limits were reached with CR-555/EVA indicator layers (0.41 ppm for isopentylamine and 1.80 ppm for cadaverine). The indicator layers based on EVA and dicyanovinyl azobenzene dyes complement the existing library of colorimetric probes for the detection of biogenic amines and show great potential for food quality control.


2006 ◽  
Vol 91 (3) ◽  
pp. 593-599 ◽  
Author(s):  
Andrea Szép ◽  
András Szabó ◽  
Nikoletta Tóth ◽  
Péter Anna ◽  
György Marosi

Sign in / Sign up

Export Citation Format

Share Document