scholarly journals High Temperature (Up to 950 °C) Sensor Based on Micro Taper In-Line Fiber Mach–Zehnder Interferometer

2019 ◽  
Vol 9 (12) ◽  
pp. 2394 ◽  
Author(s):  
Yun-Cheng Liao ◽  
Bin Liu ◽  
Juan Liu ◽  
Sheng-Peng Wan ◽  
Xing-Dao He ◽  
...  

A high temperature (up to 950 °C) sensor was proposed and demonstrated based on a micro taper in-line fiber Mach–Zehnder interferometer (MZI) structure. The fiber MZI structure comprises a single mode fiber (SMF) with two micro tapers along its longitudinal direction. An annealing at 1000 °C was applied to the fiber sensor to stabilize the temperature measurement. The experimental results showed that the sensitivity was 0.114 nm/°C and 0.116 nm/°C for the heating and cooling cycles, respectively, and, after two days, the sensor still had a sensitivity of 0.11 nm/°C, showing a good stability of the sensor. A probe-type fiber MZI was designed by cutting the sandwiched SMF, which has good linear temperature responses of 0.113 nm/°C over a large temperature range from 89 to 950 °C. The probe-type fiber MZI temperature sensor was independent to the surrounding refractive index (RI) and immune to strain. The developed sensor has a wide application prospect in the fields of high temperature hot gas flow, as well as oil and gas field development.

2017 ◽  
Vol 267 ◽  
pp. 491-495 ◽  
Author(s):  
Na Zhao ◽  
Qijing Lin ◽  
Weixuan Jing ◽  
Zhuangde Jiang ◽  
Zirong Wu ◽  
...  

Author(s):  
Charles W. Morrow

The Liquefied Natural Gas (LNG) chain of processes consumes the equivalent of 10% of initial natural gas flow for liquefaction, transportation and regasification of the natural gas. It is possible with the right process to recover some of this lost investment during the regasification process. The High Temperature Gas Cooled Reactor (HTGR) nuclear power plant appears to possess the characteristics needed to accomplish this recovery. This synergy of processes and fluid properties between an LNG regasification plant and an HTGR provides an opportunity to enhance an already efficient nuclear power generation scheme. Boiling LNG (112 K) provides an ideal cold side heat sink for the helium based Brayton cycle of the HTGR. Helium remains in the gas phase at these low temperatures. The resulting large temperature difference (1000 K) between the high temperature and low temperature sides of a thermal cycle means Carnot efficiencies approach 90%. Achievable efficiencies approach 77%, an increase from 48% for current ambient temperature cooled HTGR designs. Thus a LNG/HTGR plant can deliver half again more power for similar capital investments and operating costs. In addition, boiling LNG with helium saves fuel gas costs for the regasification plant. This paper will show that this combination is feasible and economic. Since both processes are designed to run at maximum capacity, duty cycles and plant availability criteria match. For coastal locations, both processes possess similar site selection criteria. Finally, combining the processes will impose no unmanageable safety constraints on either system and in fact could make safe operation easier to attain. This paper will provide general overviews of an HTGR power plant and of the LNG-to-market sequence, concentrating on regasification plants. The paper will then describe a process that combines an HTGR power plant with an LNG regasification facility to the advantage of both. At full load, the economic benefit for a dual installation supporting what would be a 1.1 GWe power plant before improvement would be approximately $423 million per year.


2016 ◽  
Vol 29 ◽  
pp. 6-12 ◽  
Author(s):  
Yufeng Zhang ◽  
Yongqin Yu ◽  
Chenlin Du ◽  
Shuangchen Ruan ◽  
Xue Chen ◽  
...  

Sensors ◽  
2014 ◽  
Vol 14 (8) ◽  
pp. 14210-14221 ◽  
Author(s):  
Zhongyao Feng ◽  
Jiacheng Li ◽  
Xueguang Qiao ◽  
Ling Li ◽  
Hangzhou Yang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document