scholarly journals An Effective Ground Fault Location Scheme Using Unsynchronized Data for Multi-Terminal Lines

Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2957 ◽  
Author(s):  
Dazhi Wang ◽  
Yi Ning ◽  
Cuiling Zhang

Traveling-wave-based methods perform poorly for the fault location of multi-terminal lines as a result of the limitation introduced by being a highly branched structure. The requirement for multi-terminal time synchronization is also a drawback and needs to be improved. In this paper, an effective fault location method for use on multi-terminal lines is proposed, and it does not require the data from each terminal to be synchronized. The method is based on the arrival time differences in the ground and aerial mode waves detected at each terminal. First, fault section identification rules for a three-terminal line are proposed. Then, a multi-terminal topological structure in this paper will be deemed as one consisting of multiple three-terminal lines. Thus, a whole scheme to identify any fault section in a multi-terminal line is presented. Consequently, the fault distance is calculated using the fault distance ratios in the corresponding fault section. The advantage of the proposed scheme is that complete coverage of multi-terminal lines fault location can still be achieved once some synchronized devices are out of operation. To evaluate the performance of the proposed method, many fault cases under different conditions are implemented. The simulation results show that the proposed method can identify the fault section correctly and locate the fault more accurately and reliably than existing methods.

2014 ◽  
Vol 1003 ◽  
pp. 124-129
Author(s):  
Jian Xu Lu ◽  
Cheng Jia Ma

Among the available fault location methods based on traveling waves, calibrations of wave velocity and wave arrival time are the two main problems. This paper proposes a new fault location method which combines the two problems mentioned above. In this method, the first wave and second wave obtained at one side and the first wave obtained at the other side is used to locate the fault point. And the Hilbert-Huang transform is used in the calibration of wave arrival time, making the method more accurate than using wavelet transform. This method has the following two advantages: At first, it dismisses the influence of wave velocity. In the second, it doesn’t need to distinguish the sources of the received waves. ATP-EMTP’s simulation results show that this method is available and the location precision is higher than traditional fault location methods.


IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Yougen Chen ◽  
Junbo Yin ◽  
Zhiyong Li ◽  
Renyong Wei

Author(s):  
M. A. Pardo ◽  
K. Mahtani ◽  
C. A. Platero ◽  
J. A. Sanchez-Fernandez

Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1293 ◽  
Author(s):  
Krzysztof Lowczowski ◽  
Jozef Lorenc ◽  
Jozef Zawodniak ◽  
Grzegorz Dombek

The paper analyzes the utilization of cable screen currents for earth fault identification and location. Attention is paid on cable and mixed feeders—cable and overhead lines. The principle of operation is based on utilization of 3 criterion values: Ratio of cable screen earthing current and zero sequence cable core current—RF110/15, phase shift between cable screen earthing current and zero sequence cable core current—α and cable screen admittance defined as a ratio of cable screen earthing current and zero sequence voltage—Y0cs. Earth fault location is possible thanks to discovered relation between RF110/15 and α, whereas Y0cs allows for reliable detection of earth faults. Detection and identification are very important because it allows to increase the reliability of supply—reduce downtime and number of consumers affected by the fault. The article presents a phase to ground fault current flow for different power system configurations. At the end solution, which improves location capabilities is proposed. The solution is analyzed in PSCAD software and verified by network experiment.


Author(s):  
Carlos A. Platerogaona ◽  
Jesus Serrano ◽  
Jose M. Guerrero ◽  
Alba Fernandez-Horcajuelo

Sign in / Sign up

Export Citation Format

Share Document