scholarly journals An Adjusted Weight Metric to Quantify Flexibility Available in Conventional Generators for Low Carbon Power Systems

Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5658
Author(s):  
Saleh Abujarad ◽  
Mohd Wazir Mustafa ◽  
Jasrul Jamani Jamian ◽  
Abdirahman M. Abdilahi ◽  
Jeroen D. M. De Kooning ◽  
...  

With the increasing shares of intermittent renewable sources in the grid, it becomes increasingly essential to quantify the requirements of the power systems flexibility. In this article, an adjusted weight flexibility metric (AWFM) is developed to quantify the available flexibility within individual generators as well as within the overall system. The developed metric is useful for power system operators who require a fast, simple, and offline metric. This provides a more realistic and accurate quantification of the available technical flexibility without performing time-consuming multi-temporal simulations. Another interesting feature is that it can be used to facilitate scenario comparisons. This is achieved by developing a new framework to assure the consistency of the metric and by proposing a new adjusted weighting mechanism based on correlation analysis and analytic hierarchy process (AHP). A new ranking approach based on flexibility was also proposed to increase the share of the renewable energy sources (RESs). The proposed framework was tested on the IEEE RTS-96 test-system. The results demonstrate the consistency of the AWFM. Moreover, the results show that the proposed metric is adaptive as it automatically adjusts the flexibility index with the addition or removal of generators. The new ranking approach proved its ability to increase the wind share from 28% to 37.2% within the test system. The AWFM can be a valuable contribution to the field of flexibility for its ability to provide systematic formulation for the precise analysis and accurate assessment of inherent technical flexibility for a low carbon power system.

Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3680
Author(s):  
Lasantha Meegahapola ◽  
Siqi Bu

Power network operators are rapidly incorporating wind power generation into their power grids to meet the widely accepted carbon neutrality targets and facilitate the transition from conventional fossil-fuel energy sources to the clean and low-carbon renewable energy sources [...]


2020 ◽  
Author(s):  
Ana Fernández-Guillamón ◽  
Emilio Gómez-Lázaro ◽  
Eduard Muljadi ◽  
Ángel Molina-Garcia

Over recent decades, the penetration of renewable energy sources (RES), especially photovoltaic and wind power plants, has been promoted in most countries. However, as these both alternative sources have power electronics at the grid interface (inverters), they are electrically decoupled from the grid. Subsequently, stability and reliability of power systems are compromised. Inertia in power systems has been traditionally determined by considering all the rotating masses directly connected to the grid. Thus, as the penetration of renewable units increases, the inertia of the power system decreases due to the reduction of directly connected rotating machines. As a consequence, power systems require a new set of strategies to include these renewable sources. In fact, ‘hidden inertia,’ ‘synthetic inertia’ and ‘virtual inertia’ are terms currently used to represent an artificial inertia created by inverter control strategies of such renewable sources. This chapter reviews the inertia concept and proposes a method to estimate the rotational inertia in different parts of the world. In addition, an extensive discussion on wind and photovoltaic power plants and their contribution to inertia and power system stability is presented.


Author(s):  
Jianqiang Luo ◽  
Yiqing Zou ◽  
Siqi Bu

Various renewable energy sources such as wind power and photovoltaic (PV) have been increasingly integrated into the power system through power electronic converters in recent years. However, power electronic converter-driven stability issues under specific circumstances, for instance, modal resonances might deteriorate the dynamic performance of the power systems or even threaten the overall stability. In this paper, the integration impact of a hybrid renewable energy source (HRES) system on modal interaction and converter-driven stability is investigated in an IEEE 16-machine 68-bus power system. Firstly, an HRES system is introduced, which consists of full converter-based wind power generation (FCWG) and full converter-based photovoltaic generation (FCPV). The equivalent dynamic models of FCWG and FCPV are then established, followed by the linearized state-space modeling. On this basis, converter-driven stability analyses are performed to reveal the modal resonance mechanisms of the interconnected power systems and the modal interaction phenomenon. Additionally, time-domain simulations are conducted to verify effectiveness of dynamic models and support the converter-driven stability analysis results. To avoid detrimental modal resonances, an optimization strategy is further proposed by retuning the controller parameters of the HRES system. The overall results demonstrate the modal interaction effect between external AC power system and the HRES system and its various impacts on converter-driven stability.


Author(s):  
Claudia Lucia De Pascalis ◽  
Stephanie Stockar

Abstract Cogeneration is a well-known and cost effective solution for generating power and heat within the same plant, leading to improved overall efficiency and reduced generation cost. Combined heating and power systems can facilitate the penetration of renewable energy sources in medium size applications through the integration of electric and thermal energy storage units. Due to the complexity of the plant as well as significantly variability in power demand and generation, the design and operation of such systems requires a systematic co-optimization of plant and controller for guaranteeing near optimal performance. In this scenario, this paper presents a physics-based parametric modeling approach for the characterization of the main components of a 1MW combined heating and power system that includes renewable sources, electric and thermal storage devices. To demonstrate the model flexibility and potential benefits achieved by an optimal sizing, the system energy management is optimized using Dynamic Programming. The operational costs for different configurations are compared showing that an optimization of the energy management strategy in conjunction with an improved system sizing lead to more than 6% of reduction in the operational cost.


Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3310 ◽  
Author(s):  
Ignacio Blanco ◽  
Daniela Guericke ◽  
Anders Andersen ◽  
Henrik Madsen

In countries with an extended use of district heating (DH), the integrated operation of DH and power systems can increase the flexibility of the power system, achieving a higher integration of renewable energy sources (RES). DH operators can not only provide flexibility to the power system by acting on the electricity market, but also profit from the situation to lower the overall system cost. However, the operational planning and bidding includes several uncertain components at the time of planning: electricity prices as well as heat and power production from RES. In this publication, we propose a planning method based on stochastic programming that supports DH operators by scheduling the production and creating bids for the day-ahead and balancing electricity markets. We apply our solution approach to a real case study in Denmark and perform an extensive analysis of the production and trading behavior of the DH system. The analysis provides insights on system costs, how DH system can provide regulating power, and the impact of RES on the planning.


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2916
Author(s):  
Mauro Caprabianca ◽  
Maria Carmen Falvo ◽  
Lorenzo Papi ◽  
Lucrezia Promutico ◽  
Viviana Rossetti ◽  
...  

Over the last years, power systems around the globe experienced deep changes in their operation, mainly induced by the widespread of Intermittent Renewable Energy Sources (IRES). These changes involved a review of market and operational rules, in the direction of a stronger integration. At European level, this integration is in progress, driven by the new European guidelines and network codes, which deal with multiple issues, from market design to operational security. In this framework, the project TERRE (Trans European Replacement Reserve Exchange) is aimed at the realization of a European central platform, called LIBRA, for the exchange of balancing resources and, in particular, for the activation of the procured Replacement Reserve (RR) resources. The Italian Transmission System Operator (TSO), TERNA, is a participant of the project and it is testing new methodologies for the sizing of RR and its required activation throughout the TERRE process. The aim of the new methodologies is to find areas of potential improvement in the sizing of RR requirements and activation, which open up the possibility for a reduction of the procurement cost, without endangering the security of the power system. This paper describes a new RR sizing methodology, proposed by TERNA, which is based on a persistence method, showing its results on real data and highlighting key advantages and potential limitations of this approach. In order to overcome these limitations, a literature review on alternative approaches has been carried out, identifying nowcasting techniques as a relevant alternative for the very short term forecast horizon. These one could be further investigated and tested in the future, using the proposed persistence method as a benchmark.


Energies ◽  
2019 ◽  
Vol 12 (6) ◽  
pp. 1037 ◽  
Author(s):  
Arslan Bashir ◽  
Matti Lehtonen

Current energy policy-driven targets have led to increasing deployment of renewable energy sources in electrical grids. However, due to the limited flexibility of current power systems, the rapidly growing number of installations of renewable energy systems has resulted in rising levels of generation curtailments. This paper probes the benefits of simultaneously coordinating aggregated hydro-reservoir storage with residential demand response (DR) for mitigating both load and generation curtailments in highly renewable generation power systems. DR services are provided by electric water heaters, thermal storages, electric vehicles, and heating, ventilation and air-conditioning (HVAC) loads. Accordingly, an optimization model is presented to minimize the mismatch between demand and supply in the Finnish power system. The model considers proportions of base-load generation comprising nuclear, and combined heat and power (CHP) plants (both CHP-city and CHP-industry), as well as future penetration scenarios of solar and wind power that are constructed, reflecting the present generation structure in Finland. The findings show that DR coordinated with hydropower is an efficient curtailment mitigation tool given the uncertainty in renewable generation. A comprehensive sensitivity analysis is also carried out to depict how higher penetration can reduce carbon emissions from electricity co-generation in the near future.


Sign in / Sign up

Export Citation Format

Share Document