scholarly journals Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time

Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6749
Author(s):  
Farkad A. Lattieff ◽  
Mohammed A. Atiya ◽  
Jasim M. Mahdi ◽  
Hasan Sh. Majdi ◽  
Pouyan Talebizadehsardari ◽  
...  

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational at the unequal adsorption/desorption times. The performance of the system with equal time is almost twice that of the unequal one. The roles of adsorption velocity, adsorption capacity, overall heat transfer coefficient, and the performance of the cooling system are also evaluated.

2018 ◽  
Vol 22 (5) ◽  
pp. 2151-2162
Author(s):  
Jose Marcos ◽  
Raquel Lizarte ◽  
Fernando Varela ◽  
Maria Palacios-Lorenzo ◽  
Ana Blanco-Marigorta

A solar cooling system with an optimized air-cooled double-effect water/LiBr absorption machine is proposed as a sustainable alternative to meet cooling demands in dry hot climates. This system allows eliminating the cooling towers in those regions of the planet where water is scarce. This work analyses the environmental benefits of this air-cooled system, as well as its environmental foot-prints, compared to a solar water-cooled single effect. In this regard, a methodology has been applied to calculate the annual saving in water consumption produced in a case study: a hospital located in Almer?a, in South of Spain. Further-more, the reduction in energy consumption and CO2 emissions is also quantified since this machine can be driven by solar energy and with higher efficiency than those of single effect.


2018 ◽  
Vol 77 (3) ◽  
pp. 141-148
Author(s):  
M. Yu. Khvostik ◽  
I. V. Khromov ◽  
O. A. Bykova ◽  
G. A. Beresten’

The monitoring of railway rails damage on the railway network of the JSC “Russian Railways” as well as operational and polygon tests are conducted with the purpose of assessing the impact of operating conditions on the intensity of rails damage, obtaining initial data for forecasting rails failures. The increased intensity of rails wear on sites with a complex plan and profile leads to the fact that with a continuous change from the track, rails which have an underutilized service life of more than 20 % are retrieved. Polygon tests on the Test Loop of the JSC “VNIIZhT” near the Scherbinka station can provide the repeatability and reliability of the results, comparative tests are carried out under identical conditions and their duration is several times less than when tested at experimental sites under operational conditions. The results of the polygon tests of new differentially heat-strengthened rails did not reveal any advantages in the wear resistance of special purposed rails (laid in the recommended radius of the curve for its application) when comparing the rails of domestic manufacturers. Metal shelling out on the rolling surface of rails is the main reason for the removal of rails from test batches. The origin and development of defects of this kind is due to both violations of the technology of manufacturing rails, and because of violations of the current maintenance of the track. The metal stock in the area of the rail head of R65 type due to the increase in its dimensions positively affects the extension of the lifetime of the rails, reducing the cost of the life cycle and the rail itself, and the design of the track as a whole. When carrying out a separate study in order to obtain results characterizing the stability of high-quality rails to contact fatigue damage, it is advisable to optimize the conditions of the polygon tests, bringing them closer to operational ones. When forming the test results, it is necessary to expand the list of criteria for assessing the wear resistance of rails, supplementing it with the size of the wear area at the time of a certain operating time of the tonnage, with the introduction of this criterion into the appropriate methods for the polygon (operational) tests.


Author(s):  
Jan Albers ◽  
Giovanni Nurzia ◽  
Felix Ziegler

The efficient operation of a solar cooling system strongly depends on the chiller behaviour under part-load conditions since driving energy and cooling load are never constant. For this reason the performance of a single stage, hot water driven 30 kW H2O/LiBr-absorption chiller employed in a solar cooling system with a field of 350 m2 evacuated tube collectors has been analysed under part-load conditions with both simulations and experiments. A simulation model has been developed for the whole absorption chiller (Type Yazaki WFC-10), where all internal mass and energy balances are solved. The connection to the external heat reservoirs of hot, chilled and cooling water is done by lumped and distributed UA-values for the main heat exchangers. In addition to an analytical evaporator model — which is described in detail — experimental correlations for UA-values have been used for condenser, generator and solution heat exchanger. For the absorber a basic model based on Nusselt theory has been employed. The evaporator model was developed taking into account the distribution of refrigerant on the tube bundle as well as the change in operation from a partially dry to an overflowing evaporator. A linear model is derived to calculate the wetted area. The influence of these effects on cooling capacity and COP is calculated for three different combinations of hot and cooling water temperature. The comparison to experimental data shows a good agreement in the various operational modes of the evaporator. The model is able to predict the transition from partially dry to an overflowing evaporator quite well. The present deviations in the domain with high refrigerant overflow can be attributed to the simple absorber model and the linear wetted area model. Nevertheless the results of this investigation can be used to improve control strategies for new and existing solar cooling systems.


2017 ◽  
Vol 76 ◽  
pp. 63-72 ◽  
Author(s):  
A. Acuña ◽  
F. Lara ◽  
P. Rosales ◽  
J. Suastegui ◽  
N. Velázquez ◽  
...  