scholarly journals Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents

Materials ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2274
Author(s):  
Victor S. Costache ◽  
Jorn P. Meekel ◽  
Andreea Costache ◽  
Tatiana Melnic ◽  
Crina Solomon ◽  
...  

Recently, multilayer stents for type B aortic dissections (TBAD) have been proposed to decrease false lumen flow, increase and streamline true lumen flow, and retain branch vessel patency. We aimed to provide a protocol with standardized techniques to investigate aortic remodeling of TBAD by multilayer flow modulators (MFM) in static geometric and hemodynamic analyses. Combining existing literature and new insights, a standardized protocol was designed. Using pre- and postoperative CT scans, geometric models were constructed, lumen dimensions were calculated, computational fluid dynamics (CFD) models were composed, and velocity and pressures were calculated. Sixteen TBAD cases treated with MFM were included for analysis. For each case, aortic remodeling was analyzed using post-processing medical imaging software. After 3D models were created, geometrical anatomical measurements were performed, and meshes for finite element analysis were generated. MFM cases were compared pre- and postoperatively; true lumen volumes increased (p < 0.001), false lumen volumes decreased (p = 0.001), true lumen diameter at the plane of maximum compression (PMC) increased (p < 0.001), and false lumen index decreased (p = 0.008). True lumen flow was streamlined, and the overall fluid velocity and pressures decreased (p < 0.001 and p = 0.006, respectively). This protocol provided a standardized method to evaluate the effects of MFM treatments in TBAD on geometric analyses, PMC, and CFD outcomes.

2020 ◽  
pp. 152660282096699
Author(s):  
Yaowang Lin ◽  
Shaohong Dong ◽  
Jianfan Luo ◽  
Weijie Bei ◽  
Qiyun Liu ◽  
...  

Purpose To compare the clinical outcomes after thoracic endovascular aortic repair (TEVAR) with a bare stent to those after TEVAR alone in patients with complicated acute type B aortic dissection (cATBAD). Materials and Methods A prospective, randomized trial was conducted at 2 medical centers in China between 2010 and 2013. Patients with cATBAD were randomly assigned to receive TEVAR with a bare stent (n=42) or TEVAR only (n=42). Patients were scheduled to undergo computed tomography angiography at 3, 6, and 12 months and then annually to 5 years. The primary endpoint was all-cause mortality at 5 years; secondary outcomes were a composite of complications (endoleak, stent-graft–induced new entry, aortic rupture, and secondary intervention) and aortic remodeling at 1 and 5 years. Results All-cause death occurred in 1 (2.4%) patient in the TEVAR with bare stent group (lung cancer) and 5 patients (11.9%) in the TEVAR group (4 aorta-related) during the 5-year follow-up (log-rank p=0.025). The 1- and 5-year rates of complications and secondary interventions did not differ between the groups. Patients in the TEVAR with bare stent group had higher increases in the thoracic true lumen diameter (19.7±3.6 vs 17.0±6.2 mm, p=0.018) and abdominal true lumen diameter (13.7±4.8 vs 7.2±6.1 mm, p<0.001) and a higher incidence of complete false lumen thrombosis (80.9% vs 47.6%, p=0.005) at the 1-year follow-up. However, no between-group differences in the changes of aortic remodeling parameters were observed between the 1- and 5-year follow-up periods. Conclusion The addition of a distal bare stent to a thoracic stent-graft during TEVAR was associated with significantly improved long-term survival in cATBAD patients vs TEVAR only, likely due to the prevention of true lumen collapse and improvement of complete false lumen thrombosis of the dissected aorta.


Author(s):  
Mariafrancesca Fiorentino ◽  
Hector W L de Beaufort ◽  
Uday Sonker ◽  
Robin H Heijmen

Abstract OBJECTIVES The frozen elephant trunk technique is an increasingly common treatment for extensive disease of the thoracic aorta. The objective of the study was to evaluate the outcomes of frozen elephant trunk specifically in chronic (residual) aortic dissections, focusing on downstream aortic remodelling. METHODS Between 2013 and 2019, a total of 28 patients were treated using the Vascutek Thoraflex hybrid graft at our institution for chronic dissections/post-dissection aneurysms. Immediate and follow-up outcomes were studied, as well as the changes in total aortic diameter, true lumen and false lumen diameter and the status of the false lumen at 3 different levels of the thoraco-abdominal aorta. RESULTS No in-hospital or 30-day mortality was observed, temporary paraparesis rate was 7% and disabling stroke incidence was 14.3%. Freedom from all-cause mortality at 2 years was 91.6 ± 5.7%, while freedom from reintervention on the downstream aorta at 2 years was 59.1 ± 10.8%. Positive aortic remodelling was achieved in 50.0%, with an enlargement in the true lumen and a reduction of the false lumen not only at the level of the proximal descending aorta with 73.1% of complete thrombosis but also at the level of the distal descending thoracic aorta, with 41.7% of complete thrombosis. CONCLUSIONS The frozen elephant trunk is a good solution in chronic (residual) downstream aortic dissections inducing positive aortic remodelling and preventing from II stage operations or allowing an endovascular approach.


Vascular ◽  
2015 ◽  
Vol 24 (2) ◽  
pp. 187-193 ◽  
Author(s):  
D Kotelis ◽  
G Grebe ◽  
P Kraus ◽  
M Müller-Eschner ◽  
M Bischoff ◽  
...  

Aim To identify morphologic factors affecting aortic expansion in patients with uncomplicated type B aortic dissections. Methods Computed tomography data of 24 patients (18 male; median age: 61 years), diagnosed with acute uncomplicated type B aortic dissections between 2002 and 2013, were retrospectively reviewed. All patients had at least two computed tomography angiography scans and six months of uneventful follow-up. Computed tomography scans were assessed by two independent readers with regard to presence and number of entry tears. Thoracic and abdominal aortic diameters were derived using image processing software. Results Twenty-two of 24 patients showed aortic expansion over a median computed tomography angiographic follow-up of 33.2 months. Annual rates showed an increase of 1.7 mm for total aortic diameter, 2.1 mm for the false and a decrease of −0.4 mm for the true lumen. In three patients (12.5%), aortic diameter exceeded 60 mm during follow-up, and all three patients underwent thoracic endovascular aortic repair. Patients with a maximum aortic diameter <4 cm at baseline showed a significantly higher expansion rate compared to cases with an initial maximum aortic diameter of ≥4 cm ( p=0.0471). A median of two entries (range: 1–5) was recognized per patient. Presence of more than two entry tears ( n = 13) was associated with faster overall diameter expansion (mean annual rates: 2.18 mm vs. 1.16 mm; p = 0.4556), and decrease of the cross-sectional surface of the true lumen over time (annual rate for > 2 entries vs. ≤2 entries: −7.8 mm2 vs. +37.5 mm2; p = 0.0369). Median size of entry tears was 12 mm (range: 2–53 mm). Conclusions The results presented herein suggest that uncomplicated type B aortic dissection patients with more than two entry tears and/or an initial maximum aortic diameter of<4 cm are at risk for aortic dilatation and, therefore, may require stricter follow-up including the possible need for early intervention.


2014 ◽  
Vol 63 (12) ◽  
pp. A2064
Author(s):  
Keith Thompson ◽  
Armen Chalian ◽  
Ryan Clare ◽  
Yuh-Jer Shen ◽  
Michael Jorgensen ◽  
...  

2021 ◽  
Vol 12 ◽  
Author(s):  
Likun Sun ◽  
Jiehua Li ◽  
Lunchang Wang ◽  
Quanming Li ◽  
Hao He ◽  
...  

Background: Acute type B aortic dissection is a highly serious aortic pathology. Aortic geometric parameters may be useful variables related to the occurrence of acute type B aortic dissection (aTBAD). The aim of the study is to delineate the alteration in aortic geometric parameters and analyze the specific geometric factors associated with aTBAD.Methods: The propensity score matching method was applied to control confounding factors. The aortic diameter, length, angulation, tortuosity, and type of aortic arch of the aTBAD and control group were retrospectively analyzed via three-dimensional computed tomography imaging created by the 3mensio software (version 10.0, Maastricht, The Netherlands). The geometric variables of true lumen and false lumen in the descending aorta were measured to estimate the severity of aortic dissection. Multivariable logistic regression models were used to investigate the significant and specific factors associated with aTBAD occurrence. The area under the receiver operating characteristic curve (AUC) was used to estimate the performance of the model.Results: After propensity score matching, 168 matched pairs of patients were selected. The ascending aorta and aortic arch diameters were dilated, and the ascending aorta and total aorta lengths were elongated in aTBAD group significantly (P &lt; 0.001). The ascending aorta and aortic arch angulations in the aTBAD group were sharper than those of the controls (P = 0.01, P &lt; 0.001, respectively). The aortic arch and total aorta tortuosities were significantly higher in the aTBAD group (P = 0.001, P &lt; 0.001, respectively). There were more type III arch patients in the aTBAD group than the controls (67.9 vs. 22.6%). The true lumen angulation was sharper than that in the false lumen (P &lt; 0.01). The true lumen tortuosity was significantly lower than that in the false lumen (P &lt; 0.001). The multivariable models identified that aortic arch angulation, tortuosity, and type III arch were independent and specific geometric factors associated with aTBAD occurrence. The AUC of the multivariable models 1, 2, 3 were 0.945, 0.953, and 0.96, respectively.Conclusions: The sharper angulation and higher tortuosity of aortic arch and type III arch were the geometric factors associated with aTBAD in addition to the ascending aorta elongation and aortic arch dilation. The angulation and tortuosity of the true and false lumens may carry significant clinical implications for the treatment and prognosis of aTBAD.


Circulation ◽  
2000 ◽  
Vol 102 (suppl_3) ◽  
Author(s):  
Hiromu Terai ◽  
Nobushige Tamura ◽  
Tatsuo Nakamura ◽  
Kazunobu Nishimura ◽  
Norimasa Tsutsui ◽  
...  

Background —Despite recent progress in medical and surgical treatment, acute type B aortic dissection still carries a high mortality rate. We have developed a novel cylindrical balloon catheter for less invasive treatment to block the entry of the dissection and induce thrombotic occlusion of the false lumen. The balloon has the shape of a sheet when deflated but a double-cylinder shape when inflated. Therefore, aortic blood flow is maintained through the cylindrical lumen during balloon inflation. Methods and Results —Six beagle dogs underwent a left thoracotomy at the 6th intercostal space. An acute dissection of 4-cm length was created surgically on the descending aorta. The balloon catheter was inserted through the distal descending aorta and advanced to the entry site. The balloon catheter was inflated for 6 hours. The blood flow in the descending aorta and the position of the balloon was monitored by color Doppler echovasculography. Four dogs were killed humanely on the following day and 2 dogs 10 days after the surgery. The descending aorta was examined macroscopically and microscopically in all dogs. In all dogs, the false lumen was occluded by thrombi. Although no dog had clinical evidence of distal thromboembolism, 2 of the 4 dogs that were killed on the second postoperative day had fresh mural thrombi in the true lumen. Conclusions —The false lumen of the acute type B aortic dissection was effectively occluded by the novel cylindrical balloon catheter in the canine experimental model. The thrombus formation in the true lumen is the problem to be solved.


2020 ◽  
pp. 152660282095072
Author(s):  
Victor S. Costache ◽  
Jorn P. Meekel ◽  
Andreea Costache ◽  
Tatiana Melnic ◽  
Cristian Bucurenciu ◽  
...  

Purpose To report a single-center series of patients with type B aortic dissection treated with the Multilayer Flow Modulator (MFM). Materials and Methods Over a 36-month period, 23 patients (median age 53 years; 20 men) with complicated type B aortic dissections (2 acute, 5 subacute, and 16 chronic) were treated with the MFM. Primary endpoints of rupture or dissection-related death, overall mortality, and reintervention were evaluated using the Kaplan-Meier method; estimates for freedom from the endpoints are reported with the 95% confidence interval (CI). Secondary outcomes included technical success, adverse events, and aortic remodeling. Clinical and imaging data were collected preoperatively, directly postoperatively, and annually to 36 months for analysis using computational fluid dynamics (CFD). Results Initial technical success was 91.3%. The estimates of the endpoints at 12 months were 100% for freedom from rupture or aortic-related death, 95.7% for freedom from overall mortality, and 91.3% for freedom from reintervention. No device-related neurological or systemic complications occurred, and no additional reinterventions were needed during follow-up. A total of 144 branches overstented by the MFM remained patent. Morphologic analysis of the aortic dissection showed progressive true lumen volume increase (75.9%, p<0.001) with concomitant false lumen volume decrease (42.8%, p<0.001); the CFD analyses showed increased laminar flow. Conclusion In the current series, the MFM provided a safe and feasible treatment option for complicated acute, subacute, and chronic type B aortic dissections, with high technical success, low mortality, and active aortic remodeling. Further studies should elucidate the long-term safety of the MFM and its effectiveness in a larger patient cohort.


Sign in / Sign up

Export Citation Format

Share Document