scholarly journals Bending Fracture of Different Zirconia-Based Bioceramics for Dental Applications: A Comparative Study

Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6887
Author(s):  
Peter Fischer ◽  
Horia Mihail Barbu ◽  
Caroline Adela Ingrid Fischer ◽  
Mihaela Pantea ◽  
Florin Baciu ◽  
...  

The fabrication of fixed dental prostheses using aesthetic materials has become routine in today’s dentistry. In the present study, three-unit full zirconia fixed prosthetic restorations obtained by computer-aided design/computer-aided manufacturing (CAD/CAM) technology were tested by bending trials. The prostheses were intended to replace the first mandibular left molar and were manufactured from four different types of zirconia bioceramics (KatanaTM Zirconia HTML and KatanaTM Zirconia STML/Kuraray Noritake Dental Inc.; NOVAZir® Fusion float® ml/NOVADENT/Dentaltechnik; and 3D PRO Zirconia/Bloomden Bioceramics). In total, sixteen samples were manufactured—four samples per zirconia material. Additionally, the morphology, grain size area distribution, and elemental composition were analyzed in parallelepiped samples made from the selected types of zirconia in three different areas, noted as the upper, middle, and lower areas. The scanning electron microscope (SEM) analysis highlighted that the grain size area varies with respect to the researched area and the type of material. Defects such as microcracks and pores were also noted to a smaller extent. In terms of grain size area, it was observed that most of the particles in all samples were under 0.5 μm2, while the chemical composition of the investigated materials did not vary significantly. The results obtained after performing the bending tests showed that a zirconia material with fewer structural defects and an increased percentage of grain size area under 0.5 µm2, ranging from ~44% in the upper area to ~74% in the lower area, exhibited enhanced mechanical behavior. Overall, the resulting values of all investigated parameters confirm that the tested materials are suitable for clinical use.

Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1401
Author(s):  
Doo-Bin Song ◽  
Man-So Han ◽  
Si-Chul Kim ◽  
Junyong Ahn ◽  
Yong-Woon Im ◽  
...  

This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titanium FDPs by CAD/CAM milling. A total of six FDPs were sequentially milled in one titanium alloy disk using a new set of burs every time (n = 4). The fitting accuracy of FDPs was mesiodistally evaluated by a silicone replica technique and the measurement was triplicated at four different locations: MO (marginal opening), MG (marginal gap), AG (axial gap), and OG (occlusal gap). Data were statistically analyzed using ANOVA and Tukey’s HSD test. The fitting accuracy of PMMA (polymethyl methacrylate) FDPs milled using the worn or new bur were evaluated by the same procedure (n = 6). The mean dimensions of titanium FDP for all measuring positions, except for AG, were significantly increased from the third milling. However, no difference was noted between the first FDP and the second FDP milled with the same set of burs. Severe edge chippings were observed in all milling burs. Detrimental effects of the worn burs on the fitting accuracy were demonstrated in the CAD/CAM-milled PMMA FDP. The results recommend proper changing frequency of cutting burs to achieve the quality of fit and predictable outcomes for dental CAD/CAM prostheses.


2020 ◽  
Vol 10 (21) ◽  
pp. 7735
Author(s):  
Hai Yen Mai ◽  
Jae-Min Seo ◽  
Jae-Kwang Jung ◽  
Du-Hyeong Lee

Occlusal contact loss occasionally occurs following the placement of implant-supported fixed dental prostheses in the posterior region. This complication is caused by the change in the vertical dimension of occlusion after the recovery of mastication. The change is probably related to the prosthesis sinking phenomenon and previous mandibular dislocation. The use of interim prostheses could help re-establish the vertical dimension of occlusion. The definitive prostheses can then be accurately fabricated using digital techniques in the newly established vertical dimension. In this case report, we introduce a protocol incorporating a computer-aided design and computer-aided manufacturing (CAD-CAM) interim prosthesis and digital techniques to minimize the occurrence of unexpected initial occlusal changes in the prosthetic treatment of implant-supported prostheses in the posterior region.


Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5588
Author(s):  
Angelika Rauch ◽  
Sebastian Hahnel ◽  
Elena Günther ◽  
Wolfgang Bidmon ◽  
Oliver Schierz

The aim of this study was to compare the clinical properties of tooth-colored computer-aided design/computer-aided manufacturing (CAD/CAM) materials for the fabrication of a 3-unit fixed dental prostheses (FDPs) in the same clinical scenario. A 53-year-old female patient was supplied with a 3-unit FDP to replace a second premolar in the upper jaw. Restorations were fabricated from 3 mol%, 4 mol%, and 5 mol% yttrium oxide zirconia, zirconia with translucency gradient, indirect composite resin, polyetheretherketone (PEEK), and polyetherketoneketone (PEKK). Milling time, weight, and radiopacity were investigated. Esthetics were examined following the US Public Health Service criteria (USPHS). The milling time for zirconia was twice as high as for the indirect composite resin, PEEK, or PEKK. The latter materials had a weight of 2 g each, while zirconia restorations yielded 5 g. Zirconia presented intense radiopacity. PEEK and PEKK required veneering and an opaquer was applied to the PEKK framework. All FDPs showed acceptable esthetics. PEEK and PEKK restorations were featured by a grayish shimmering. A variety of CAD/CAM materials are available to fabricate 3-unit FDPs with esthetically acceptable results. In the esthetic zone, PEEK and PEKK require veneering and an opaquer might be applied. Milling time, weight, and radiopacity were relatively high for zirconia FDPs.


Prosthesis ◽  
2020 ◽  
Vol 2 (4) ◽  
pp. 325-332
Author(s):  
Kelly M. Suralik ◽  
Jie Sun ◽  
Chia-Yu Chen ◽  
Sang J. Lee

There has been an increase in utilizing 3D printers in dental restorations. The purpose of the study is to compare mechanical properties of 3D-printed prostheses to those of self-cured and/or computer-aided design-computer-aided manufacturing (CAD-CAM) restorations. A metal master typodont was prepared for the mandibular left sextant with implant analogs embedded at the first premolar and first molar positions with a missing second premolar. Three-unit provisional fixed dental prosthesis (FDP) was designed utilizing the 3Shape tooth library and forty-five uniform specimens were fabricated with different materials: self-cured poly(methyl methacrylate) (PMMA) (N = 15), milled PMMA CAD-CAM blocks (N = 15) and 3D-printed resin (N = 15). All specimens were tested using an Instron machine at a crosshead speed of 0.5 mm/min by an axial load on the occlusal surface of the second premolar pontic site. Statistical analysis was completed with Shapiro-Wilk, ANOVA and Tukey post-hoc tests. Mean fracture force was 300.61 N, 294.64 N and 408.49 N for self-cured PMMA, milled PMMA and 3D-printed resin, respectively. Mean force at FDP fracture of 3D-printed resin was significantly greater than the mean fracture force of either self-cured (p = 0.016, 95% CI [17.86, 197.91]) or milled (p = 0.010, 95% CI [23.83, 203.88]) PMMA.


Author(s):  
A. N. Bozhko

Computer-aided design of assembly processes (Computer aided assembly planning, CAAP) of complex products is an important and urgent problem of state-of-the-art information technologies. Intensive research on CAAP has been underway since the 1980s. Meanwhile, specialized design systems were created to provide synthesis of assembly plans and product decompositions into assembly units. Such systems as ASPE, RAPID, XAP / 1, FLAPS, Archimedes, PRELEIDES, HAP, etc. can be given, as an example. These experimental developments did not get widespread use in industry, since they are based on the models of products with limited adequacy and require an expert’s active involvement in preparing initial information. The design tools for the state-of-the-art full-featured CAD/CAM systems (Siemens NX, Dassault CATIA and PTC Creo Elements / Pro), which are designed to provide CAAP, mainly take into account the geometric constraints that the design imposes on design solutions. These systems often synthesize technologically incorrect assembly sequences in which known technological heuristics are violated, for example orderliness in accuracy, consistency with the system of dimension chains, etc.An AssemBL software application package has been developed for a structured analysis of products and a synthesis of assembly plans and decompositions. The AssemBL uses a hyper-graph model of a product that correctly describes coherent and sequential assembly operations and processes. In terms of the hyper-graph model, an assembly operation is described as shrinkage of edge, an assembly plan is a sequence of shrinkages that converts a hyper-graph into the point, and a decomposition of product into assembly units is a hyper-graph partition into sub-graphs.The AssemBL solves the problem of minimizing the number of direct checks for geometric solvability when assembling complex products. This task is posed as a plus-sum two-person game of bicoloured brushing of an ordered set. In the paradigm of this model, the brushing operation is to check a certain structured fragment for solvability by collision detection methods. A rational brushing strategy minimizes the number of such checks.The package is integrated into the Siemens NX 10.0 computer-aided design system. This solution allowed us to combine specialized AssemBL tools with a developed toolkit of one of the most powerful and popular integrated CAD/CAM /CAE systems.


Sign in / Sign up

Export Citation Format

Share Document