scholarly journals Awake Implementation of Extracorporeal Life Support in Refractory Cardiogenic Shock

Medicina ◽  
2021 ◽  
Vol 58 (1) ◽  
pp. 43
Author(s):  
Julia Riebandt ◽  
Thomas Haberl ◽  
Klaus Distelmaier ◽  
Martin H. Bernardi ◽  
Anne-Kristin Schaefer ◽  
...  

Background and objectives: Extracorporeal life support (ECLS) is a widely accepted and effective strategy for use in patients presenting with refractory cardiogenic shock. Implantation in awake and non-intubated patients allows for optimized evaluation of further therapy options while avoiding potential side effects associated with the need for sedation and intubation. The aim of the study was the assessment of safety and feasibility of awake ECLS implementation and of outcomes in patients treated with this concept. Materials and Methods: We retrospectively reviewed the concept of awake ECLS implantation in 16 consecutive patients (mean age 58 ± 8 years; male: 88%; ischemic cardiomyopathy: 50%) from 02/2017 to 01/2021. Study endpoints were survival to weaning or bridging to durable support or organ replacement and development of end-organ function and hemodynamic parameters on ECLS. Results: Fourteen patients (88%) were able to be successfully transitioned to definite therapy options. ECLS support stabilized end-organ function, led to a decrease in mean lactate levels (5.3 ± 3.7 mmol/L at baseline to 1.9 ± 1.3 mmol/L 12 h after ECLS start; p = 0.01) and improved hemodynamics (median central venous pressure 20 ± 5 mmHg vs. 10 ± 2 mmHg, p = 0.001) over a median duration of two days (1–8 days IQR). Two patients (13%) died on ECLS support due to multi-organ dysfunction syndrome. Survival to discharge of initially successfully bridged or weaned patients was 64%. Conclusions: Awake ECLS implantation is feasible and safe with the key advantage of omitting or delaying general anesthesia and intubation, with their associated risks in cardiogenic-shock patients, facilitating further decision making.

2015 ◽  
Vol 49 (3) ◽  
pp. 802-809 ◽  
Author(s):  
Sabina P. W. Guenther ◽  
Stefan Brunner ◽  
Frank Born ◽  
Matthias Fischer ◽  
René Schramm ◽  
...  

Author(s):  
Ali İhsan Hasde ◽  
Mehmet Cahit Sarıcaoğlu ◽  
Nur Dikmen Yaman ◽  
Çağdaş Baran ◽  
Evren Özçınar ◽  
...  

Abstract OBJECTIVES Our goal was to compare the haemodynamic effects of different mechanical left ventricular (LV) unloading strategies and clinical outcomes in patients with refractory cardiogenic shock supported with venoarterial extracorporeal membrane oxygenation (VA-ECMO). METHODS A total of 448 patients supported with VA-ECMO for refractory cardiogenic shock between 1 March 2015 and 31 January 2020 were included and analysed in a single-centre, retrospective case–control study. Fifty-three patients (11.8%) on VA-ECMO required LV unloading. Percutaneous balloon atrial septostomy (PBAS), intra-aortic balloon pump (IABP) and transapical LV vent (TALVV) strategies were compared with regards to the composite rate of death, procedure-related complications and neurological complications. The secondary outcomes were reduced pulmonary capillary wedge pressure, pulmonary artery pressure, central venous pressure, left atrial diameter and resolution of pulmonary oedema on a chest X-ray within 48 h. RESULTS No death related to the LV unloading procedure was detected. Reduction in pulmonary capillary wedge pressure was highest with the TALVV technique (17.2 ± 2.1 mmHg; P < 0.001) and was higher in the PBAS than in the IABP group; the difference was significant (9.6 ± 2.5 and 3.9 ± 1.3, respectively; P = 0.001). Reduction in central venous pressure with TALVV was highest with the other procedures (7.4 ± 1.1 mmHg; P < 0.001). However, procedure-related complications were significantly higher with TALVV compared to the PBAS and IABP groups (50% vs 17.6% and 10%, respectively; P = 0.015). We observed no significant differences in mortality or neurological complications between the groups. CONCLUSIONS Our results suggest that TALVV was the most effective method for LV unloading compared with PBAS and IABP for VA-ECMO support but was associated with complications. Efficient LV unloading may not improve survival.


2017 ◽  
Vol 69 (11) ◽  
pp. 1186
Author(s):  
Suzanne de Waha ◽  
Steffen Desch ◽  
Tobias Graf ◽  
Georg Fuernau ◽  
Ingo Eitel ◽  
...  

2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Painvin B ◽  
◽  
Le Balc’h P ◽  
Gicquel T ◽  
Camus C ◽  
...  

Venlafaxine has critical side effects from arrhythmias to cardiogenic shock after toxic dose ingestion. We report a case of venlafaxine intoxication with Multiple Organ Failure (MOF) treated with Veno-Arterial Extracorporeal Life Support (VA-ECLS). A 60-year old male with a history of chronic depression ingested 72 tablets of prolonged-release venlafaxine hydrochloride 75 mg (total 5400 mg). Initial EKG showed broadened QRS complexes and Transthoracic Echocardiography (TTE) revealed diffuse ventricular hypokinesia with Left Ventricular Ejection Fraction (LVEF) of 15% for which dobutamine infusion was started. Due to persistent refractory cardiogenic shock and MOF, a Medos® Deltastream® VA-ECLS was surgically implanted in our intensive care unit. On day 1, toxicology analysis found plasma concentrations of venlafaxine 3.2mg/L and its metabolite desmethylvenlafaxine at 0.92 mg/L. At day 6, we performed a weaning trial, enabling ECLS removal. Motion defect of anteroseptal and inferolateral walls was also noticed. EKGs showed a shorten R wave in the anteroseptal territory leading to the potential diagnosis of underlying ischemic cardiomyopathy. The patient was extubated at day-10 and discharged for cardiology unit at day-17. At day-20, cardiac magnetic resonance imaging showed no sign of ischemia and TTE parameters were normalized. This is the first report of refractory cardiogenic shock and MOF due to venlafaxine intoxication treated with VA-ECLS. The main objective of ECLS is to restore cardiac output especially when ventricular failure is refractory to inotropes. Our experience suggests that MOF secondary to refractory cardiogenic shock should quickly prompt the implantation of a VA-ECLS in venlafaxine critical overdose.


2017 ◽  
Vol 106 (5) ◽  
pp. 379-385 ◽  
Author(s):  
Suzanne de Waha ◽  
Tobias Graf ◽  
Steffen Desch ◽  
Georg Fuernau ◽  
Ingo Eitel ◽  
...  

2016 ◽  
Vol 11 (12) ◽  
pp. 1363-1371 ◽  
Author(s):  
Suzanne de Waha ◽  
Georg Fuernau ◽  
Steffen Desch ◽  
Ingo Eitel ◽  
Ariane Wiedau ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document