scholarly journals Development, Optimization, and Comparison of Different Sample Pre-Treatments for Simultaneous Determination of Vitamin E and Vitamin K in Vegetables

Molecules ◽  
2020 ◽  
Vol 25 (11) ◽  
pp. 2509
Author(s):  
Antonella Aresta ◽  
Gualtiero Milani ◽  
Maria Lisa Clodoveo ◽  
Carlo Franchini ◽  
Pietro Cotugno ◽  
...  

The absence of vitamin E from the diet can lead to cardiovascular disease, cancer, cataracts, and premature aging. Vitamin K deficiency can lead to bleeding disorders. These fat-soluble vitamins are important nutritional factors that can be determined in different methods in vegetables. In this work, the simultaneous determination of α-tocopherol, α-tocopheryl acetate, phylloquinone, and menaquinone-4 by gas chromatography–mass spectrometry (GC–MS) has been optimized using both direct injection and solid phase microextraction (SPME). Three different sample pre-treatment approaches based on: (A) solid–liquid–liquid–liquid extraction (SLE–LLE), (B) SLE, and (C) SPME were then applied to extract the target analytes from vegetables samples using menaquinone as internal standard. All the procedures allowed the determination of the target analytes in onion, carrot, celery, and curly kale samples. Similar results were obtained with the three different approaches, even if the one based on SPME offers the best performance, together with a reduced use of solvent, time consumption, and experimental complexity, which makes it the preferable option for industrial applications.

1989 ◽  
Vol 72 (2) ◽  
pp. 349-354 ◽  
Author(s):  
Lee Q Huang

Abstract A multiresidue method was developed for the simultaneous determination of low parts per billion (ppb) concentrations of the herbicides alachlor, metolachlor, atrazine, and simazine in water and soil using isotope dilution gas chromatography/mass spectrometry (GC/MS). Known amounts of 15N,13C-alachlor and 2H5-atrazine were added to each sample as internal standards. The samples were then prepared by a solid phase extraction with no further cleanup. A high resolution GC/low resolution MS system with data acquisition in selected ion monitoring mode was used to quantitate herbicides in the extract. The limit of detection was 0.05 ppb for water and 0.5 ppb for soil. Accuracy greater than 80% and precision better than 4% was demonstrated with spiked samples.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Lidong Cao ◽  
Hua Jiang ◽  
Jing Yang ◽  
Li Fan ◽  
Fengmin Li ◽  
...  

The toxic inert ingredients in pesticide formulations are strictly regulated in many countries. In this paper, a simple and efficient headspace-gas chromatography-mass spectrometry (HSGC-MS) method using fluorobenzene as an internal standard (IS) for rapid simultaneous determination of benzene and toluene in pesticide emulsifiable concentrate (EC) was established. The headspace and GC-MS conditions were investigated and developed. A nonpolar fused silica Rtx-5 capillary column (30 m×0.20 mmi.d. and 0.25 μm film thickness) with temperature programming was used. Under optimized headspace conditions, equilibration temperature of 120°C, equilibration time of 5 min, and sample size of 50 μL, the regression of the peak area ratios of benzene and toluene to IS on the concentrations of analytes fitted a linear relationship well at the concentration levels ranging from 3.2 g/L to 16.0 g/L. Standard additions of benzene and toluene to blank different matrix solutions 1ead to recoveries of 100.1%–109.5% with a relative standard deviation (RSD) of 0.3%–8.1%. The method presented here stands out as simple and easily applicable, which provides a way for the determination of toxic volatile adjuvant in liquid pesticide formulations.


Sign in / Sign up

Export Citation Format

Share Document