scholarly journals The Application of Active Biomonitoring with the Use of Mosses to Identify Polycyclic Aromatic Hydrocarbons in an Atmospheric Aerosol

Molecules ◽  
2021 ◽  
Vol 26 (23) ◽  
pp. 7258
Author(s):  
Paweł Świsłowski ◽  
Pavel Hrabák ◽  
Stanisław Wacławek ◽  
Klára Liskova ◽  
Vojtěch Antos ◽  
...  

The use of biological indicators of environmental quality is an alternative method of monitoring ecosystem pollution. Various groups of contaminants, including organic ones, can be measured in environmental samples. Polycyclic aromatic hydrocarbons (PAHs) have not yet been determined by the moss bag technique. This technique uses several moss species simultaneously in urban areas to select the best biomonitoring of these compounds, which are dangerous to humans and the environment. In this research, a gas chromatography coupled with mass spectrometry was used for the determination of selected PAHs in three species of mosses: Pleurozium schreberi, Sphagnum fallax and Dicranum polysetum (active biomonitoring) and for comparison using an air filter reference method for atmospheric aerosol monitoring. The chlorophyll fluorescence of photosystem II (PSII) was also measured to assess changes in moss viability during the study. As a result of the study, the selective accumulation of selected PAHs by mosses was found, with Pleurozium schreberi being the best bioindicator—9 out of 13 PAHs compounds were determined in this species. The photosynthetic yield of photosystem (II) decreased by 81% during the exposure time. The relationship between PAHs concentrations in mosses and the total suspended particles (TSP) on the filter indicated the possibility of using this bioindicator to trace PAHs in urban areas and to apply the moss bag technique as a method supporting classical instrumental air monitoring.

2021 ◽  
Vol 232 (1) ◽  
Author(s):  
Alessa Maria Ceratti ◽  
Gustavo Marques da Costa ◽  
Darlan Daniel Alves ◽  
Laura Meneguzzi Cansi ◽  
Jessica Hansen ◽  
...  

2009 ◽  
Vol 57 (16) ◽  
pp. 7440-7444 ◽  
Author(s):  
Monia Perugini ◽  
Gabriella Di Serafino ◽  
Alessandra Giacomelli ◽  
Piotr Medrzycki ◽  
Anna Gloria Sabatini ◽  
...  

2021 ◽  
Vol 9 ◽  
Author(s):  
Caroline Scaramboni ◽  
Jordan Brizi Neris ◽  
Rita de Kássia Silva do Nascimento ◽  
Natasha Leandra Chiaranda da Rosa ◽  
Jonatas Schadeck Carvalho ◽  
...  

This work describes the optimization of an extraction method for the determination of polycyclic aromatic hydrocarbons (PAHs) and their nitro- and oxy-PAH derivatives in atmospheric particulate matter (PM) samples, and demonstrates that this method is also effective for the determination of levoglucosan. The optimization of the extraction solvents was performed using a three-component mixture design with the solvents dichloromethane, methanol, and acetonitrile. The number of extractions, volume of solvent, and duration of extraction in an ultrasonic bath were optimized using a full factorial design followed by a central composite design. The analyses were performed by gas chromatography coupled with mass spectrometry. The optimized conditions of the method were three extractions using 4.0 ml of acetonitrile, with ultrasonication for 34 min. The proposed method presented good linearity (r > 0.990) and acceptable precision for low (100 ng ml−1, RSD: 1–16%), medium (300 ng ml−1, RSD: 1–19%), and high (500 ng ml−1, RSD: 2–16%) concentrations of PAHs. The limits of quantification for different PAHs ranged from 10 to 50 ng ml−1, which were suitable for atmospheric PM. Assessment of the method using sample matrix spiking/recovery assays, as well as use of a reference method, showed good recoveries for levoglucosan and for most of the PAHs and their derivatives, except for the most volatile compounds, which were lost during the evaporation of the solvent. The results for PM samples extracted by the optimized method and the reference method were in good agreement. The proposed method required 97% less solvent than the reference method, shortened the analysis time by 85%, and proved to be accurate and precise for the determination of at least 27 PAHs and their derivatives present in PM samples collected with a low-volume sampler.


2014 ◽  
Vol 192 ◽  
pp. 83-90 ◽  
Author(s):  
Wei Li ◽  
Chen Wang ◽  
Hongqijie Wang ◽  
Jiwei Chen ◽  
Huizhong Shen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document