scholarly journals Inertial and Magnetic Sensor Data Compression Considering the Estimation Error

Sensors ◽  
2009 ◽  
Vol 9 (8) ◽  
pp. 5919-5932 ◽  
Author(s):  
Young Soo Suh
Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 516
Author(s):  
Brinnae Bent ◽  
Baiying Lu ◽  
Juseong Kim ◽  
Jessilyn P. Dunn

A critical challenge to using longitudinal wearable sensor biosignal data for healthcare applications and digital biomarker development is the exacerbation of the healthcare “data deluge,” leading to new data storage and organization challenges and costs. Data aggregation, sampling rate minimization, and effective data compression are all methods for consolidating wearable sensor data to reduce data volumes. There has been limited research on appropriate, effective, and efficient data compression methods for biosignal data. Here, we examine the application of different data compression pipelines built using combinations of algorithmic- and encoding-based methods to biosignal data from wearable sensors and explore how these implementations affect data recoverability and storage footprint. Algorithmic methods tested include singular value decomposition, the discrete cosine transform, and the biorthogonal discrete wavelet transform. Encoding methods tested include run-length encoding and Huffman encoding. We apply these methods to common wearable sensor data, including electrocardiogram (ECG), photoplethysmography (PPG), accelerometry, electrodermal activity (EDA), and skin temperature measurements. Of the methods examined in this study and in line with the characteristics of the different data types, we recommend direct data compression with Huffman encoding for ECG, and PPG, singular value decomposition with Huffman encoding for EDA and accelerometry, and the biorthogonal discrete wavelet transform with Huffman encoding for skin temperature to maximize data recoverability after compression. We also report the best methods for maximizing the compression ratio. Finally, we develop and document open-source code and data for each compression method tested here, which can be accessed through the Digital Biomarker Discovery Pipeline as the “Biosignal Data Compression Toolbox,” an open-source, accessible software platform for compressing biosignal data.


2013 ◽  
Vol 25 (11) ◽  
pp. 2434-2447 ◽  
Author(s):  
Nguyen Quoc Viet Hung ◽  
Hoyoung Jeung ◽  
Karl Aberer

Author(s):  
Mohamed Khalil ◽  
Ioannis Kouroudis ◽  
Roland Wüchner ◽  
Kai-Uwe Bletzinger

Abstract Structural health monitoring is spreading widely across engineering domains. Its added value is not restricted to observing structural behavior, but crosses over to enabling the assessment of structural integrity under varying operating conditions. Damage prognosis is one vital demand from structural health monitoring solutions. Many methods have been developed to update damage predictions based on sensor data, nonetheless the selection and positioning of sensors to alleviate the prediction errors remains a question under investigation. In this work, an optimal sensor placement method is proposed for fatigue damage prediction in structures. An optimization problem is formulated to minimize the a-posteriori damage estimation error based on a Kalman filter. The derivation of the objective function is presented, along with a discussion of algorithm-related issues. Finally, the mentioned damage prediction approach is applied to two structures to verify the adequacy of the sensor configurations proposed by the method.


2016 ◽  
Vol 11 (2) ◽  
pp. 178-185 ◽  
Author(s):  
Yunji Li ◽  
Li Peng

We consider a sensor data transmission policy for receding horizon recursive state estimation in a networked linear system. A good tradeoff between estimation error and communication rate could be achieved according to a transmission strategy, which decides the transfer time of the data packet. Here we give this transmission policy through proving the upper bound of system performance. Moreover, the lower bound of system performance is further analyzed in detail. A numerical example is given to verify the potential and effectiveness of the theoretical results.


Author(s):  
Chenxi Tu ◽  
Eijiro Takeuchi ◽  
Alexander Carballo ◽  
Chiyomi Miyajima ◽  
Kazuya Takeda

Sign in / Sign up

Export Citation Format

Share Document