scholarly journals Study on the Coupled Heat Transfer Model Based on Groundwater Advection and Axial Heat Conduction for the Double U-Tube Vertical Borehole Heat Exchanger

2020 ◽  
Vol 12 (18) ◽  
pp. 7345
Author(s):  
Linlin Zhang ◽  
Zhonghua Shi ◽  
Tianhao Yuan

In this paper, a dynamic heat transfer model for the vertical double U-tube borehole heat exchanger (BHE) was developed to comprehensively address the coupled heat transfer between the in-tube fluid and the soil with groundwater advection. A new concept of the heat transfer effectiveness was also proposed to evaluate the BHE heat exchange performance together with the index of the heat transfer rate. The moving finite line heat source model was selected for heat transfer outside the borehole and the steady-state model for inside the borehole. The data obtained in an on-site thermal response test were used to validate the physical model of the BHE. Then, the effects of soil type, groundwater advection velocity, inlet water flow rate, and temperature on the outlet water temperature of BHE were explored. Results show that ignoring the effects of groundwater advection in sand gravel may lead to deviation in the heat transfer rate of up to 38.9% of the ground loop design. The groundwater advection fosters the heat transfer of BHE. An increase in advection velocity may also help to shorten the time which takes the surrounding soil to reach a stable temperature. The mass flow rate of the inlet water to the BHE should be more than 0.5 kg·s−1 but should not exceed a certain upper limit under the practical engineering applications with common scale BHE. The efficiency of the heat transfer of the double U-tube BHE was determined jointly by factors such as the soil’s physical properties and the groundwater advection velocity.

ELKHA ◽  
2017 ◽  
Vol 9 (1) ◽  
pp. 8
Author(s):  
Rusadi Rusadi

Abstract–Issues about the energy crisis and clean energy in the environment become an important issue. Energy that meets the above properties is solar energy. Utilization is highly dependent on climate and weather conditions in accordance with the geographical location of the place. Optimization of energy absorption needs to be done and this is usually done by conditioning or manipulating some parameters so that the level of energy absorption is more effective and efficient.This research is an expriment research by optimizing the absorption of heat energy to heat water according to climate and weather conditions in Pontianak, West Kalimantan. The variable to be conditioned or arranged so that the maximum heat transfer rate is the flow rate of the water fluid to be heated.The experimental results show that the water flow rate of 2450 ccm DHW Loop side for SHW has a temperature difference value on the exit side of the heat exchanger which is smaller than the others. This shows that the more effective the release and absorption of heat made by the fluid in the heat exchanger. Keywords– Solar energy, Solar Water Heater (SHW), fluid flow rate, heat transfer rate


2020 ◽  
Vol 9 (1) ◽  
pp. 1793-1798

A heat exchanger is a device intensively used for enhancing the transfer of heat energy between two or more working fluids at different temperature, which are in thermal contact. The optimal design and efficient operation of heat exchanger and heat transfer network are of a great significance in any of the process industry. The heat transfer efficiency depends on both design of heat exchanger and property of working fluid. From various types of heat exchanger, the double stacked shell and tube heat exchanger with straight tube and single pass is to be under study. Here the redesign of heat exchanger takes place with the key objectives of optimizing the pressure drop, optimizing the heat transfer rate and reducing the saddle support weight used for cooling purpose in brewery application. The design calculations are carried out using the Kerns and Bell Delwar method and other important parameters dealing with material selection and geometries are also taken into consideration. FEA analysis for optimizing the saddle support weight is carried out using Dassault systeme’s Solidworks while the CFD analysis for optimizing pressure drop and heat transfer rate is carried out using Dassault systeme’s Solidworks analysis software and the design and working of Shell and tube heat exchanger is determined in terms of variables such as pressure ,temperature ,mass flow rate ,flow rate ,energy input output that are of particular interest in Shell and tube heat exchanger analysis.


To Study on rate of heat transfer in heat exchanger using helical coils has been studied by many researchers. There is less published literature available on varying pitch helical coil heat exchanger and detail characteristics of helical coil varying pitch by keeping constant curvature ratio considering heat exchange between fluid to fluid heat exchanger for laminar flow condition not available in the present available literature. Hence in present study three different coils with varying pitches are used to investigate the heat transfer characteristics of a Helical Coil Heat Exchanger. Hence coil of 25mm, 30mm, 35mm are used by keeping constant curvature ratio (=0.0667), experiment is conducted to study the influence of varying pitch on effectiveness, heat transfer rate, over all heat transfer co-efficient and Nusselt Number. The experiments is conducted in horizontal counter steady flow condition and changing the flow rate of hot fluid, pitch of helical coil heat exchanger. The results show that the varying pitch of helical coil heat exchanger has influence on heat transfer characteristics. The effectiveness of the helical coil heat exchanger is decreases with increase in mass flow rate of the hot fluid inside helical tube for varying pitch considered for study. The heat transfer rate of the helical coil heat exchanger is increases with increase in Dean Number of the hot fluid inside helical tube for varying pitch considered for study. The overall heat transfer coefficient increases with increasing hot water mass flow rate. The Nussult Number at different dean number increases for increasing helical coil pitch however the trend of average heat transfer rate for increasing M Number for varying pitch observed similar. By increasing the coil pitch of helical coil heat exchanger decreases Nussult Number, inside overall heat transfer coefficient, heat transfer rate and effectiveness.


2006 ◽  
Vol 128 (10) ◽  
pp. 1050-1059 ◽  
Author(s):  
Todd M. Bandhauer ◽  
Akhil Agarwal ◽  
Srinivas Garimella

A model for predicting heat transfer during condensation of refrigerant R134a in horizontal microchannels is presented. The thermal amplification technique is used to measure condensation heat transfer coefficients accurately over small increments of refrigerant quality across the vapor-liquid dome (0<x<1). A combination of a high flow rate closed loop primary coolant and a low flow rate open loop secondary coolant ensures the accurate measurement of the small heat duties in these microchannels and the deduction of condensation heat transfer coefficients from measured UA values. Measurements were conducted for three circular microchannels (0.506<Dh<1.524mm) over the mass flux range 150<G<750kg∕m2s. Results from previous work by the authors on condensation flow mechanisms in microchannel geometries were used to interpret the results based on the applicable flow regimes. The heat transfer model is based on the approach originally developed by Traviss, D. P., Rohsenow, W. M., and Baron, A. B., 1973, “Forced-Convection Condensation Inside Tubes: A Heat Transfer Equation For Condenser Design,” ASHRAE Trans., 79(1), pp. 157–165 and Moser, K. W., Webb, R. L., and Na, B., 1998, “A New Equivalent Reynolds Number Model for Condensation in Smooth Tubes,” ASME, J. Heat Transfer, 120(2), pp. 410–417. The multiple-flow-regime model of Garimella, S., Agarwal, A., and Killion, J. D., 2005, “Condensation Pressure Drop in Circular Microchannels,” Heat Transfer Eng., 26(3), pp. 1–8 for predicting condensation pressure drops in microchannels is used to predict the pertinent interfacial shear stresses required in this heat transfer model. The resulting heat transfer model predicts 86% of the data within ±20%.


2013 ◽  
Vol 448-453 ◽  
pp. 3259-3269
Author(s):  
Zhi Wei Li ◽  
Hong Zhou He ◽  
Huang Huang Zhuang

The characteristics of the external heat exchanger (EHE) for a 4 MWth circulation fluidized bed combustor were studied in the present paper. The length, width and height of EHE were 1.5 m, 0.8 m and 9 m, respectively. The circulating ash flow passing the heating surface bed could be controlled by adjusting the fluidizing air flow and the heating transferred from the circulating ash to the cooling water. The ash flow rate passing through the heat transfer bed was from 0.4 to 2.2 kg/s. The ash average temperature was from 500 to 750 °C. And the heat transfer rate between the ash and the cooling water was between 150 and 300 W/(m2·°C). The relationships among the circulating ash temperature, the heat transfer, heat transfer rate, the heat transfer coefficient and the circulating ash flow passing through the heating exchange cell were also presented and could be used for further commercial EHE design.


2014 ◽  
Vol 924 ◽  
pp. 329-335 ◽  
Author(s):  
Cong Hang Li ◽  
Shi Chen Jiang ◽  
Zheng Ping Yao ◽  
Song Sheng ◽  
Xin Jian Jiang ◽  
...  

Based on the nanoporous network structure features of silica aerogel, the gas-solid coupled heat transfer model of silica aerogel is analyzed, and the calculation formulas of the gas-solid coupled, the gas thermal conductivity and the heat radiation within the aerogel are derived. The thermal conductivity of pure silica aerogel is calculated according to the derived heat transfer model and is also experimentally measured. Moreover, measurements on the thermal conductivities of silica aerogel composites with different densities at ambient conditions are performed. And finally, a novel design of silica aerogel based integrated structure and thermal insulation used for withstanding the harsh thermal environment on the Martin surface is presented.