Dentistry. General requirements for instruments and related accessories used in dental implant placement and treatment

2012 ◽  
Author(s):  
Elçin Bedeloğlu ◽  
Mustafa Yalçın ◽  
Cenker Zeki Koyuncuoğlu

The purpose of this non-random retrospective cohort study was to evaluate the impact of prophylactic antibiotic on early outcomes including postoperative pain, swelling, bleeding and cyanosis in patients undergoing dental implant placement before prosthetic loading. Seventy-five patients (45 males, 30 females) whose dental implant placement were completed, included to the study. Patients used prophylactic antibiotics were defined as the experimental group and those who did not, were defined as the control group. The experimental group received 2 g amoxicillin + clavulanic acid 1 h preoperatively and 1 g amoxicillin + clavulanic acid twice a day for 5 days postoperatively while the control group had received no prophylactic antibiotic therapy perioperatively. Data on pain, swelling, bleeding, cyanosis, flap dehiscence, suppuration and implant failure were analyzed on postoperative days 2, 7, and 14 and week 12. No statistically significant difference was detected between the two groups with regard to pain and swelling on postoperative days 2, 7, and 14 and week 12 ( p >0.05), while the severity of pain and swelling were greater on day 2 compared to day 7 and 14 and week 12 in both groups ( p =0.001 and p <0.05, respectively). Similarly, no significant difference was found between the two groups with regard to postoperative bleeding and cyanosis. Although flap dehiscence was more severe on day 7 in the experimental group, no significant difference was found between the two groups with regard to the percentage of flap dehiscence assessed at other time points. Within limitations of the study, it has been demonstrated that antibiotic use has no effect on implant failure rates in dental implant surgery with a limited number of implants. We conclude that perioperative antibiotic use may not be required in straightforward implant placement procedures. Further randomized control clinical studies with higher numbers of patients and implants are needed to substantiate our findings.


Author(s):  
Judd Sher ◽  
Kate Kirkham-Ali ◽  
Denny Luo ◽  
Catherine Miller ◽  
Dileep Sharma

The present systematic review evaluates the safety of placing dental implants in patients with a history of antiresorptive or antiangiogenic drug therapy. The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines were followed. PubMed, Cochrane Central Register of Controlled Trials, Scopus, Web of Science, and OpenGrey databases were used to search for clinical studies (English only) to July 16, 2019. Study quality was assessed regarding randomization, allocation sequence concealment, blinding, incomplete outcome data, selective outcome reporting, and other biases using a modified Newcastle-Ottawa scale and the Joanna Briggs Institute critical appraisal checklist for case series. A broad search strategy resulted in the identification of 7542 studies. There were 28 studies reporting on bisphosphonates (5 cohort, 6 case control, and 17 case series) and one study reporting on denosumab (case series) that met the inclusion criteria and were included in the qualitative synthesis. The quality assessment revealed an overall moderate quality of evidence among the studies. Results demonstrated that patients with a history of bisphosphonate treatment for osteoporosis are not at increased risk of implant failure in terms of osseointegration. However, all patients with a history of bisphosphonate treatment, whether taken orally for osteoporosis or intravenously for malignancy, appear to be at risk of ‘implant surgery-triggered’ MRONJ. In contrast, the risk of MRONJ in patients treated with denosumab for osteoporosis was found to be negligible. In conclusion, general and specialist dentists should exercise caution when planning dental implant therapy in patients with a history of bisphosphonate and denosumab drug therapy. Importantly, all patients with a history of bisphosphonates are at risk of MRONJ, necessitating this to be included in the informed consent obtained prior to implant placement. The James Cook University College of Medicine and Dentistry Honours program and the Australian Dental Research Foundation Colin Cormie Grant were the primary sources of funding for this systematic review.


2013 ◽  
Vol 70 (6) ◽  
pp. 586-594 ◽  
Author(s):  
Zoran Vlahovic ◽  
Branko Mihailovic ◽  
Zoran Lazic ◽  
Mileta Golubovic

Background/Aim. Flapless implant surgery has become very important issue during recent years, mostly thanks to computerization of dentistry and software planning of dental implants placements. The aim of this study was to compare flap and flapless surgical techniques for implant placement through radiographic and radiofrequency analyses. Methods. The experiment was made in five domestic pigs. Nine weeks following domestic pigs teeth extraction, implants were placed, on the right side using surgical technique flap, and flapless on the left side. Digital dental Xrays were applied to determine primary dental implant stability quality (ISQ). At certain intervals, not later than three months, the experimental animals were sacrificed, and just before it, control X-rays were applied to measure dental implants stability. Results. Radiographic analysis showed that peri-implant bone resorption in the first 4 weeks following placement implants with flap and flapless surgical techniques was negligible. After the 3 months, mean value of peri-implant bone resorption of the implants placed using flap technique was 1.86 mm, and of those placed using flapless technique was 1.13 mm. In relation to the primary dental implant stability in the first and second week there was an expected decrease in ISQ values, but it was less expressed in the dental implants placed using the flapless technique. In the third week the ISQ values were increased in the dental implants placed by using both techniques, but the increase in flapless implant placement was higher (7.4 ISQ) than in flap implant placement (1.5 ISQ). The upward trend continued in a 4- week period, and after 3 months the dental implant stability values in the implants placed using flap technique were higher than the primary stability for 7.1 ISQ, and in the implants placed using flapless technique were higher comparing to the primary stability for 10.1 ISQ units. Conclusion. Based on the results of radiographic and resonance frequency analyses it can be concluded that the flapless technique in surgical implants placemat, leads to better results.


Author(s):  
Giovanni de Almeida Prado Di Giacomo ◽  
Patrícia Cury ◽  
Airton Moreira da Silva ◽  
Jorge Vicente Lopes da Silva ◽  
Carlos Eduardo Pompeo Souto ◽  
...  

This study was designed to evaluate the accuracy of a novel computer-designed and selectively laser sintered surgical guide for flapless dental implant placement in the edentulous jaw. Fifty dental implants were placed in 11 patients with at least one totally edentulous jaw. Initially, cone-beam computed tomography (CBCT) was performed in each patient to define the virtual position of the dental implants based on the assessment of bone availability and the proposed dental prosthesis. After virtual planning, 3D surgical guides were printed using selective laser sintering. CBCT was repeated after the surgery, and the pre-and postoperative images were overlapped in the CAD software to compare the planned and actual positions of the dental implants using a one-sample t-test. The mean ± angular standard deviation between the long axes of the planned and final dental implant positions was 4.58 ±2.85 degrees; The linear deviation in the coronal position was  0.87 ± 0.49 mm and  in the apical region of the dental implants was 1.37 ± 0.69 mm. These differences were statistically significant (p <0.001). The proposed modifications reduced the deviations, resulting in an improvement in the technique. We were able to place implants and temporary prostheses using the present protocol, taking into account the differences between the planned and final positions of the dental implants.


2016 ◽  
Vol 8 (1) ◽  
pp. 13 ◽  
Author(s):  
HashemMotahir Al-Shamiri ◽  
Samir Elfaki ◽  
SadeqAli Al-Maweri ◽  
NaderAhmed Alaizari ◽  
Bassel Tarakji

Sign in / Sign up

Export Citation Format

Share Document