scholarly journals Calculation of Fire Resistance of Reinforced Concrete Column by the Zone Method

Author(s):  
Lidija MILOŠEVIĆ ◽  
Dušica PEŠIĆ
2014 ◽  
Vol 661 ◽  
pp. 111-117 ◽  
Author(s):  
Ahmad Zakiah ◽  
Ahmad Nursafarina ◽  
Azerai Ali Rahman ◽  
Hanizah Abdul Hamid ◽  
Mohammad Soffi Md Noh

This paper reports the investigation on the fire resistance performance of reinforced concrete column with embedded permanent formwork from woodwool board (WWCB). A series of slender column embedded with and without WWCB with cross-sections 200 mm x 200 mm for column without WWCB and 300 mm x 300 mm with embedded 50 mm thick WWCB. The height of the slender column was 2000 mm. The fire resistance test was performed in accordance with BS 476-22:1987 for two (2) hours fire exposure. The fire resistance test for the embedded column with WWCB was classified as “good” in resisting fire and heat transfer.


2014 ◽  
Vol 919-921 ◽  
pp. 491-494
Author(s):  
Jian Kui Zhao ◽  
Peng Yan ◽  
Da Peng Li ◽  
Yan Liu

fire resistance model of reinforced concrete column was built by ABAQUS, and the model was validated with experiment. Temperature field and fire resistance of reinforced concrete column exposed to fire with heating and cooling phase was analyzed. The results show that Temperature field of reinforced concrete column would elevate when the environment temperature descended, and deformation and internal forces became more severity.