scholarly journals MODERN METHODS OF REACTIVE POWER COMPENSATION IN PETROCHEMICAL PRODUCTION

2022 ◽  
Vol 1 (15) ◽  
pp. 22-28
Author(s):  
Igor' Golovanov ◽  
Alena Alekseeva ◽  
Vladimir Proskuryakov ◽  
Roman Samchuk

Electrical circuits of reactive power compensation on the basis of thyristor control circuits in the power supply system of oil refineries are considered. The main advantages, advantages over traditional reactive power compensation systems and directions of introduction into the power supply system of modern production are formulated.

2013 ◽  
Vol 321-324 ◽  
pp. 1414-1417 ◽  
Author(s):  
Jing Chen ◽  
Qi Jian Cheng ◽  
You Xin Yuan ◽  
Wei Yang

The objective of this work is to research on a SVC auto-compensation method to improve the power factor of the power supply system. Firstly, the principles of the reactive power compensation of FC+TCR are analyzed qualitatively. According to the deficiencies of this compensator, a novel SVC auto-compensating method based on the variable reactor is presented. The reactor controlled by anti-parallel thyristors is namely as the variable reactor in this method. The secondary-side equivalent inductance of the variable reactor is varied by adjusting the SCR firing angles. And then, the equivalent inductance of the variable reactor of the compensator branch is adjusted indirectly for compensating the corresponding reactive power after the working conditions of the load are changed. Therefore, the auto-compensating of this var compensator is realized. The auto-compensating principles of this compensator have been analyzed, and a research on the compensating parameters of this compensator is given emphatically in this paper. Finally, the essential operation steps of this SVC compensation method are given. The research of this paper has laid a theoretical foundation for this compensator in industrial applications.


Author(s):  
V.Z Manusov ◽  
P.V. Matrenin ◽  
N. Khasanzoda

Optimization of a power supply system is one of the main directions in power engineering research. The reactive power compensation reduces active power losses in transmission lines. In general, researches devoted to allocation and control of the compensation units consider this issue as a static optimization problem. However, it is dynamic and stochastic optimization problem that requires a real-time solution. To solve the dynamic optimization NP-hard problem, it is advisable to use Swarm Intelligence. This research deals with the problem of the compensation units power control as a dynamic optimization problem, considering the possible stochastic failures of the compensation units. The Particle Swarm Optimization and the Bees Algorithm were applied to solve it to compare the effectiveness of these algorithms in the dynamic optimization of a power supply system.


Author(s):  
Elena Ivanovna Gracheva ◽  
Muhayo Islomovna Toshkhodzhaeva ◽  
Okhunbobo Saifidinovich Rakhimov ◽  
Ayubjon Jumaevich Vohidov ◽  
Ismoiljon Ilkhomovich Ismoilov

2020 ◽  
Vol 1 (1) ◽  
pp. 21-30
Author(s):  
Olena Levon ◽  
Igor Domnin

The expediency of using a power active filter in the mode of reactive power compensation of the supply network for the powerful sounding pulses shaper power supply system of the Institute of ionosphere NAS and MES of Ukraine is shown. An analysis of the literature has been carried out, which shows the effectiveness of solving the problem of reactive power compensation, filtering higher harmonics of the power supply network using active filtering of higher harmonics of current or voltage using an additional energy source to obtain a compensating signal in the form of current or voltage. The choice of the power circuit for constructing a power active filter has been made. A voltage inverter on IGBT transistors is used as a power active filter. The basic principles of operation of the power active filter control system are described, which are based on the p-q theory of power and provide for the calculation of instantaneous values ​​of the task currents for each phase of a three-phase power supply system. The work of the Matlab-model of the power supply system of the shaper is shown, the oscillograms of the main energy characteristics of the shaper are given. As a result of using a power active filter, the current of the supply network becomes close to sinusoidal, and the power factor tends to 1. A positive effect on the efficiency of the shaper when the power active filter is included in the supply network is noted, which is due to the efficiency of compensation of the reactive power consumed by the shaper from the supply network. The simulation results are presented, in particular, graphs of reactive power change at the point of connecting the power active filter to the supply network, at different levels of reactive power consumption by the shaper. The results obtained confirmed the possibility of using a power active filter in the mode of reactive power compensation of the supply network when solving the problems of improving the electromagnetic compatibility of powerful sounding pulses shapers with the supply network, reducing losses and increasing the reliability of the shapers. Keywords: active power filter, reactive power control, control systems


2019 ◽  
Vol 3 (8 (99)) ◽  
pp. 13-22
Author(s):  
Valeriy Yagup ◽  
Katerina Yagup ◽  
Yuliia Kovalova ◽  
Viktor Kharchenko ◽  
Tetiana Besarab ◽  
...  

2021 ◽  
Vol 288 ◽  
pp. 01019
Author(s):  
Vladimir Govorun ◽  
Oleg Govorun ◽  
Vadim Markovskiy ◽  
Aliya Zhumadirova

In this paper, on the basis of simulation modeling, an algorithm for studying the current resonance that occurs in the power supply system with a chaotic change of the load power and variation of reactive power compensation degree, in the presence of consumers with a nonlinear current-voltage characteristic is proposed. It is shown that overloading of capacitor banks can occur in a wide frequency range, close to the resonant frequency. The proposed algorithm determines all possible frequencies at which an increase of currents in capacitor banks can occur above the permissible values in parallel resonance. The purpose of the proposed work: to show in what operating modes of the enterprise power supply system an overload of capacitors by currents of higher harmonics can occur when the load power changes and the degree of reactive power compensation varies.


2012 ◽  
Vol 150 ◽  
pp. 170-173
Author(s):  
Shu Chao Geng ◽  
Jian Sheng Zhang

Improving power factor will enhance the efficiency of power-using and the economization on energy. This article analyzes reactive power compensation in several methods, and does a detailed technical comparison. With actual situation of enterprises, some views are put forward for reactive power optimization.


Sign in / Sign up

Export Citation Format

Share Document