RP-HPLC Assay for Estimation of Pitavastatin in Bulk and Pharmaceutical Dosage Forms

Author(s):  
K Tirumala ◽  
CH.V.S Gautam ◽  
J Gangadhar ◽  
M Jayajeevitha ◽  
Vanitha Prakash K

Reverse phase high performance liquid chromatographic (RP-HPLC) method was developed and validated for the estimation of pitavastatin in tablet dosage form. A Phenomenex Luna C18, 150×4.6 mm i.d, 5 µm particle size with mobile phase consisting of buffer 0.01M potassium dihydrogen ortho phosphate pH (3.75) adjusted with dilute orthophosphoric and acetonitrile in the ratio of 20:80 v/v was used. The flow rate was 1.2 mL/min and eluents were monitored at 248 nm. The retention time was 4.1min. The detector response was linear in the concentration of 25-150 µg/mL, with the regression coefficient of 0.9998. Quantification was done by calculating area of the peak and the limit of detection and limit of quantification were 1.9 µg/mL and 5.7 µg/mL respectively. The percentage assay of pitavastatin was 101.1%. The results of study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate which is useful for the routine determination of pitavastatin in bulk drug and in its pharmaceutical dosage forms.

INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (01) ◽  
pp. 20-25
Author(s):  
S. M Samyuktha ◽  
◽  
P. G Prasanthi ◽  
K Mahesh ◽  
B. N Nalluri ◽  
...  

A simple, selective, accurate High Performance Liquid Chromatographic (HPLC) method was developed and validated for the analysis of Fenspiride hydrochloride in bulk and tablet dosage forms. Chromatographic separation was achieved isocratically using a C18 reverse phase column [Inertsil C18 column (250×4.6mm, 5μm)] utilizing a mobile phase containing 10mM Ammonium acetate: Acetonitrile (50:50 v/v) at a flow rate of 1 mL/min. The eluents were monitored at wavelength of 210 nm for a run time of 7 minutes at ambient temperature. The average retention time of the drug was found to be 4.6 minutes. The developed method was validated as per ICH guidelines to ascertain the reproducibility of the method. The method was found to be linear in the concentration range of 10-50 μg/mL with a good correlation coefficient of 0.998. The limit of detection (LOD) and limit of quantification (LOQ) were 0.007 and 0.021 μg/mL and the percentage recovery and assay were found to be 99.315 and 98.97%. Specificity with placebo by 3 D plots showed that the method was specific and free from interfering substances. Therefore, the fully validated method was good enough to carry out routine analysis of Fenspiride in bulk and tablet formulations.


2012 ◽  
Vol 9 (2) ◽  
pp. 832-838 ◽  
Author(s):  
Srinivasu Topalli ◽  
T. G. Chandrashekhar ◽  
M. Mathrusri Annapurna

A simple, accurate, sensitive and reproducible reverse phase high performance liquid chromatographic method has been developed for the quantitative determination of Etoricoxib in pharmaceutical dosage forms. The assay was performed on Hypersil ODS C-18 (250 x 4.6 mm., 5µm particle size) column using acetonitrile and potassium dihydrogen phosphate buffer (pH 4.2) (46:54 % v/v) as mobile phase with UV detection at 280 nm (flow rate 1.2 ml/min). Bromhexine was used as an internal standard. Quantization was achieved by measurement of the peak area ratio of the drug to the internal standard. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.0704 µg ml-1and 0.2134 µg ml-1respectively. Each analysis required no longer than 10 minutes. The calibration curve was linear over the concentration range from 0.5-85.0 µg ml-1. The retention times of Etoricoxib and Bromhexine were found to be 3.083 and 7.631 minutes respectively. The proposed method was validated according to the ICH guidelines and can be used successfully to analyse marketed formulations.


2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


2012 ◽  
Vol 2012 ◽  
pp. 1-9 ◽  
Author(s):  
J. Álvarez-Fuentes ◽  
L. Martín-Banderas ◽  
I. Muñoz-Rubio ◽  
M. A. Holgado ◽  
M. Fernández-Arévalo

A simple, fast, and reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for determining of a cannabinoid derivate, which displays potent antihyperalgesic activity, 1-naphthalenyl[4-(pentyloxy)-1-naphthalenyl]methanone (CB13) into PLGA nanoparticles. Separation was achieved in a C18 column using a mobile phase consisting of two solvents: solvent A, consisting of acetonitrile : water : acetic acid (75 : 23.7 : 1.3 v/v), and solvent B, consisting of acetonitrile. An isocratic method (70 : 30 v/v), with a flow rate of 1.000 mL/min, and a diode array detector were used. The developed method was precise, accurate, and linear over the concentration range of analysis with a limit of detection and a limit of quantification of 0.5 and 1.25 μg/mL, respectively. The developed method was applied to the analysis of CB13 in nanoparticles samples obtained by three different procedures (SEV, FF, and NPP) in terms of encapsulation efficiency and drug release. Nanoparticles size and size distribution were also evaluated founding that NPP method presented the most lowest particle sizes with narrow-size distribution (≈320 nm) and slightly negative zeta potential (≈−25 mV) which presumes a suitable procedure for the synthesis of PLGA-CB13 nanoparticles for oral administration.


Author(s):  
Hemraj Sharma ◽  
Boya Madhuri ◽  
Yiragamreddy Padmanabha Reddy ◽  
Kondareddy Vinod Kumar ◽  
Nanda Kishor Bhatta ◽  
...  

A novel approach was used to develop and validate a rapid, specific, accurate and precise Reverse phase High performance liquid chromatographic (RP-HPLC) method for the simultaneous determination of Metformin and Sitagliptin in pharmaceutical dosage forms and its applications to dissolution study. The chromatographic separation was carried out on a C8 (250mm X 4.6 mm i.d., 5μm) column with a mobile phase of 40 Acetonitrile: 60 Phosphate Buffer (pH 6.8), using UV detector at 257 nm at 1ml min-1 flow rate. The retention time for Metformin was 2.11 minutes and 5.30 minutes for Sitagliptin. The Linearity for Metformin was found to be 10-80 µg ml-1 with R2 value of 0.9998 and for Sitagliptin 1-8 µg ml-1 with R2 value of 0.9976. Dissolution study of both for Metformin and Sitagliptin was carried, Percentage of drug release was established which was found to be 96.23% and 102.64% respectively, in the period of 50 minutes. Keywords: RP-HPLC, Metformin, Sitagliptin, Dissolution study


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
S. Sowjanya ◽  
Ch. Devadasu

A reverse phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for simultaneous estimation of levamisole and albendazole in drug substance and in its combinational dosage form. The analysis was carried out usingInertsil ODSC18(4.6 x 150 mm, 5μm) column, and the separation was carried out using a mobile phase containing a buffer of pH 3.5 and acetonitrile (70:30 v/v) pumped at a flow rate of 1.0 mL/min with variable wavelength UV-detection at 224 nm. Both the drugs were well resolved in the stationary phase and the retention times were 2.350 min and 4.055 for levamisole and albendazole, respectively. The method was validated and shown to be linear in the concentration range of 15-45μg/ml and 40-120μg/ml for levamisole and albendazole, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were determined based on standard deviation of the y-intercept and the slope of the calibration curve. LOD and LOQ values were 2.08μg/ml and 6.03μg/ml for levamisole and 3.15μg/ml and 10.40μg/ml for albendazole, respectively. The accuracy of the method was assessed by adding known amount of standard solution (75 %, 100 %, and 125% of the sample concentration) to the preanalyzed sample solution of 100% concentration. All the samples were prepared and analyzed in triplicate. The percentage mean recovery by standard addition experiments of levamisole and albendazole is 99.66% and 98.73%, respectively.


2010 ◽  
Vol 7 (2) ◽  
pp. 600-604 ◽  
Author(s):  
A. Lakshmana Rao ◽  
V. Naga Jahnavi

A rapid and sensitive high performance liquid chromatographic method was developed for the estimation of levetiracetam in bulk and pharmaceutical formulations. Levetiracetam was chromatographed on a reverse phase C18column in a mobile phase consisting of 0.05 M KH2PO4buffer (pH 3.0 adjusted with orthophosphoric acid) and methanol in the ratio 70:30 v/v. The mobile phase was pumped at a flow rate of 1.2 mL/min. with detection at 210 nm. The detector response was linear in the concentration of 20-120 μg/mL. The limit of detection and limit of quantification was found to be 0.0104 and 0.0317 μg/mL, respectively. The intra and inter day variation was found to be less than 1%. The mean recovery of the drug from the solution containing 100 µg/mL was 100.038 μg/mL. The proposed method is simple, fast, accurate, precise and reproducible hence can be applied for routine quality control analysis of levetiracetam in bulk and pharmaceutical formulations.