Evaluation of extra-virgin olive oil adulteration using FTIR spectroscopy combined with multivariate algorithms

2018 ◽  
Vol 10 (4) ◽  
pp. 411-421 ◽  
Author(s):  
Y. Xu ◽  
M.M. Hassan ◽  
F.Y.H. Kutsanedzie ◽  
H.H. Li ◽  
Q.S. Chen
2014 ◽  
Vol 69 (1) ◽  
Author(s):  
Abdul Rohman ◽  
Intan Gupitasari ◽  
Purwanto Purwanto ◽  
Kuwat Triyana ◽  
Arieff Salleh Rosman ◽  
...  

The presence of lard (LD) in cosmetics products is a serious matter for certain religion, like Islam. The Muslim community is not allowed to use cosmetics products containing pig derivatives such as LD. Therefore, analysis of LD in cosmetics products is highly needed. The present study highlighted the employment of Fourier transform infrared (FTIR) spectroscopy in combination with chemometrics of multivariate calibration and principle component analysis (PCA) for quantitative analysis and classification of LD in the binary mixture with extra virgin olive oil (EVOO) as oil base in cream formulations for halal authentication. The lipid component in cream was extracted using liquid-liquid extraction using hexane as extracting solvent, and the lipid obtained was subjected to FTIR spectra measurement, using horizontal attenuated total reflectance as sampling technique. The result showed that FTIR spectroscopy in combination with partial least squares can be used to quantify the levels of LD in the mixture with EVOO in cosmetics creams using the combined frequency regions of 1785-702 cm-1 and 3020-2808 cm-1. PCA using absorbance intensities at 1200 – 1000 cm-1 as variables has been successfully used for the classification of cream with and without LD in the formulation. The developed method is rapid and not involving the excessive sample preparation.


2020 ◽  
Vol 5 (1) ◽  
pp. 35-44
Author(s):  
Nuraznee Mashodi ◽  
Nurul Yani Rahim ◽  
Norhayati Muhammad ◽  
Saliza Asman

Extra virgin olive oil (EVOO) is categorized as expensive oil due to high-quality nutritional value. Unfortunately, EVOO is easily adulterated with other low-quality edible oils. Therefore, this study was done to differentiate and analyze the adulteration of EVOO with other edible oils using Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) spectroscopy. The study was used several edible oils included canola oil, corn oil, sunflower oil, and soybean oil as an adulterant for EVOO. The adulterant EVOO samples were prepared by mixing with dissimilar concentrations of the solely edible oils (20 %, 40 %, 60 % and 80 % (v/v)). The main functional groups of EVOO and other edible oils are O-H, C-H, C=C and C=O groups were assigned around 3500 cm-1, 2925 cm-1, 3006 cm-1 and 1745 cm-1 wavenumbers, respectively. From the comparison of EVOO and other adulterant edibles oil spectra, it showed that the EVOO has the lowest absorbance intensity at around 3006 cm-1 represented double bond which is closely related to the composition of oil sample. The adulteration of EVOO was evaluated by analysing the changes in the absorbance based on the linear regression analysis graph of the bands at 3006 and 2925 cm-1 and the limit of detection (LOD) was measured. The graph of A3008/A2925 with good relative coefficients (R2) and lower LOD is more favourable than the linear regression graph of A3006 versus percentage of edible oils added in EVOO. This study showed that ATR-FTIR spectroscopy is a convenient tool for analysing the adulteration of EVOO.


2015 ◽  
Vol 1 (1) ◽  
pp. 1018695 ◽  
Author(s):  
Magda Vasconcelos ◽  
Luis Coelho ◽  
Ana Barros ◽  
José Manuel Marques Martins de Almeida

2011 ◽  
Vol 26 (3) ◽  
pp. 203-211 ◽  
Author(s):  
Abdul Rohman ◽  
Y. B. Che Man

The purpose of this study was to optimize Fourier transform infrared (FTIR) spectroscopy in combination with multivariate calibrations (partial least square and principle component regression) for determination of extra virgin olive oil (EVOO) in quaternary mixture systems with grape seed oil (GSO), rice bran oil (RBO) and walnut oil (WO). FTIR spectra of EVOO in quaternary mixtures were subjected to several treatments including mean centering (MC), standard normal variate, and spectra derivatives. The combined frequency regions of 1200–900 and 2949–2885 cm–1were used for determination of EVOO. Using partial least square calibration, FTIR normal spectra treated with MC model give the highest values of coefficient of determination (R2) and the lowest values of root mean square error of calibration (RMSEC). TheR2value obtained for the relationship between actual and FTIR predicted value of EVOO was >0.99 with RMSEC value of 1.55% (v/v). The developed PLS model was further used to calculate EVOO in prediction samples, and the root mean square error of prediction obtained was 3.65% (v/v).


Sign in / Sign up

Export Citation Format

Share Document