Improvement and Design of Single Coil Vibrating-Wire Sensor Signal Acquisition System Based on STM32

2014 ◽  
Vol 511-512 ◽  
pp. 764-769
Author(s):  
Suo Ying Mao ◽  
Jun Hua Zhao ◽  
Fang Fang Zhou

Vibrating wire sensor signal acquisition system is widely used in the fields of water conservancy dam, slope, construction, mining and so on to measure osmotic pressure, soil pressure, strain and other physical quantities. This paper studies the single coil vibrating wire sensor signal acquisition system,which uses the STM32F103 core processor generating a low-voltage feedback PWM signal to excite vibrating wire with scanning frequency, after signal amplification, filtering and signal normalization through the frequency measurement module, and ultimately achieve frequency measurement. The system can improve the traditional vibrating wire acquisition instrument, so as to achieve fast and efficient and reliable long-lasting measurement. According to some simulation and designed circuit, the measured data and diagram can verify the feasibility of the method.

2011 ◽  
Vol 105-107 ◽  
pp. 2179-2182
Author(s):  
Wei Min Zhang ◽  
Shu Xuan Liu ◽  
Yong Qiu ◽  
Cheng Feng Chen

Crack propagation is the main reason which leads to the invalidity of the metal components. A set of detecting equipment based on the acoustic emission method was designed, and it was mainly composed of acoustic emission sensor, signal operating circuits and signal acquisition system. Specimens of 16MnR material were manufactured and the static axial tension test of them was carried on. Acoustic emission signals from the specimen were detected by acoustic emission equipment by using piezoelectric ceramic sensor. Signal datum were acquired and operated by the acquisition system, as well as the acquisition program written for it. The final results has demonstrated that acoustic emission equipment designed for the test performed well in acquiring the signals induced by the metal crack propagation.


Atmosphere ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 645
Author(s):  
Kristen Okorn ◽  
Michael Hannigan

As low-cost sensors have become ubiquitous in air quality measurements, there is a need for more efficient calibration and quantification practices. Here, we deploy stationary low-cost monitors in Colorado and Southern California near oil and gas facilities, focusing our analysis on methane and ozone concentration measurement using metal oxide sensors. In comparing different sensor signal normalization techniques, we propose a z-scoring standardization approach to normalize all sensor signals, making our calibration results more easily transferable among sensor packages. We also attempt several different physical co-location schemes, and explore several calibration models in which only one sensor system needs to be co-located with a reference instrument, and can be used to calibrate the rest of the fleet of sensor systems. This approach greatly reduces the time and effort involved in field normalization without compromising goodness of fit of the calibration model to a significant extent. We also explore other factors affecting the performance of the sensor system quantification method, including the use of different reference instruments, duration of co-location, time averaging, transferability between different physical environments, and the age of metal oxide sensors. Our focus on methane and stationary monitors, in addition to the z-scoring standardization approach, has broad applications in low-cost sensor calibration and utility.


2013 ◽  
Vol 462-463 ◽  
pp. 1001-1004
Author(s):  
Xue Wang ◽  
Wen Liang Niu ◽  
Yuan Sheng Liu

In order to more accurate detection of ECG signal and cost savings, this paper designed a set of ECG signal acquisition system based on Matlab. The system is composed of hardware and software. Hardware is made up of signal acquisition processing circuit and MPC82G516 microcontroller for AD conversion. The software mainly contains configuring Matlab serial to realize communication with MPC82G516 and uses abundant filter resources of Matlab to remove noise by differential, absolute value, smoothing and threshold selection algorithm of R wave detection, R wave peak provides the basis for calculating the heart rate. This paper uses Matlab friendly user interface for displaying received data to make the data more intuitive and read more easily.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Yidong Zeng ◽  
Jun Ji ◽  
Jinghua Wang ◽  
Jiasuo Gao ◽  
Jie Hu ◽  
...  

In this paper, the pulse wave feature alertness detection system based on computer software technology is researched. First, the computer software technology designs the alertness detection system and then conducts the system alertness test experiment using a system that can not affect the subjects’ alertness, a portable multichannel physiological signal acquisition system that measures the subjects’ ECG signal, skin resistance, blood oxygen saturation, and other physiological signals in the case of a degree task experiment. The multichannel physiological signal acquisition system collects the signals during the vigilance task experiment. At the same time, before, during, and after the experiment, subjects are required to fill in the Stanford Sleepiness Scale (SSS) and evaluate the level of individual alertness through subjective self-evaluation. The relevant experimental data show that, 10 minutes before the experiment, the pulse amplitude increased rapidly, then slowly decreased at the beginning, reached a peak in about 25 minutes, and then began to rise.


Sign in / Sign up

Export Citation Format

Share Document