Finite-Element Analysis of a Measuring Model for FeAlCrBSiNb Coating Bonding Strength of Revolution Body

2014 ◽  
Vol 577 ◽  
pp. 722-725
Author(s):  
Jia Ying Zhang ◽  
Gang Zhao ◽  
Ye Wang Sun ◽  
Jun Wei Yang ◽  
Huai Bin Yang

The stress distribution of the coating interface in measuring bonding strength of revolution body coating was emulated. The stress curves of coating bonding interface were obtained. The abscission characteristics of coating were analyzed. It showed that Stress concentration occurred in the symmetric centre of the coating bonding interface. The coating peeled off from the symmetric centre to both sides of the sample interface in the measuring process. Avoiding shearing stress was a method to promote the measuring test of bonding strength of revolution body coating.

2015 ◽  
Vol 41 (6) ◽  
pp. 646-651 ◽  
Author(s):  
Hakimeh Siadat ◽  
Shervin Hashemzadeh ◽  
Allahyar Geramy ◽  
Seyed Hossein Bassir ◽  
Marzieh Alikhasi

There are some anatomical restrictions in which implants are not possible to be inserted in their conventional configuration. Offset placement of implants in relation to the prosthetic unit could be a treatment solution. The aim of this study was to evaluate the effect of the offset placement of implant-supported prosthesis on the stress distribution around a dental implant using 3D finite element analysis. 3D finite element models of implant placement in the position of a mandibular molar with 4 configurations (0, 0.5, 1, 1.5 mm offset) were created in order to investigate resultant stress/strain distribution. A vertical load of 100 N was applied on the center of the crown of the models. The least stress in peri-implant tissue was found in in-line configuration (0 mm offset). Stress concentration in the peri-implant tissue increased by increasing the amount of offset placement. Maximum stress concentration in all models was detected at the neck of the implant. It can be concluded that the offset placement of a single dental implant does not offer biomechanical advantages regarding reducing stress concentration over the in-line implant configuration. It is suggested that the amount of offset should be as minimum as possible.


2019 ◽  
Vol 22 (2) ◽  
pp. 171-177
Author(s):  
Marina Gullo Augusto ◽  
Tabata Do Prado Sato ◽  
Maria José Domingues De Castro ◽  
Marcia Carneiro Valera ◽  
Alexandre Luis Souto Borges ◽  
...  

Objective: The prevalence of non-carious cervical lesions (NCCLs) has increased in the recent years, especially in the elderly population. The successful prevention and treatment of those lesions requires an understanding of the biomechanics of aged teeth. Considering the importance of such aspect, the impact of the age-related dentin deposition on the stress distribution of NCCLs was evaluated by means of finite element analysis. Material and Methods: A 2-dimensional model of a sound maxillary first premolar was created using CAD software. Two tooth geometries (sound, aged) and two lesion shapes (wedge, saucer) were simulated to the model. The mesh was built with 35,000 triangle and square elements of 0.1 mm in length. All tissues were considered isotropic, homogeneous and linear. Occlusal surfaces were loaded with 300 N for simulating normal chewing forces. The stress distribution was analyzed by a color scale and by the maximum principal stress at the cavosurface line angle. Results: The aged models presented lower stress concentration in the overall system in comparison to sound models. The sharp angle of wedge shaped lesions promoted higher stress concentration at the center of cavosurface angle, favoring the lesions progression. Conclusion: Considering the limitations of the current methodology, it is possible to conclude that aged tooth is a more compact structure that can better respond to stress loadings. This protective intrinsic mechanism should be considered when adopting preventive and restorative measures for NCCLs for the elderly.KeywordsAging; Finite element analysis; Non-carious; Cervical lesions.


2012 ◽  
Vol 236-237 ◽  
pp. 48-51
Author(s):  
Yong Tang ◽  
Xiao Cong He ◽  
Jun Chao Zheng ◽  
Kai Zeng ◽  
Yan Fang Ding ◽  
...  

Adhesively bonding technology is used increasingly by the automotive and aerospace industries. The design of reverse-bent joint is effective way for improving the bonded joint performance. The influence of preformed angle on the stress distribution of the adhesive-adherend interface is studied in this paper using finite element analysis (FEA). By comparing the results of the FEA for reverse-bent joints with different preformed angle, it can be seen that the preformed angle not only have significant influence on the stress distribution of overlap section, but also changes stress concentration at the spew fillet of bonded joint. The results also indicate that there is a best value of preformed angle in which the reverse-bent bonded joint has the best performance.


1993 ◽  
Vol 20 (2) ◽  
pp. 269-286 ◽  
Author(s):  
D. I. Nwosu ◽  
A. S. J. Swamidas ◽  
K. Munaswamy

The stress distribution along the intersection of offshore tubular T-joints under the action of axial and in-plane and out-of-plane (bending) brace loading has been investigated using degenerated shell elements. The ratios of through-thickness membrane to bending stress and bending to total stress have been obtained using a simple linear interpolation between the stresses on the inner and outer surfaces of the tube. The nominal brace stress and the maximum principal stress values have been used for stress concentration factor determination. The influence of thickness and other geometric parameters on the stress distribution along the intersection was investigated in two ways, viz., increasing the chord thickness while maintaining a constant brace thickness, and keeping the chord thickness constant while reducing the brace thickness.Comparison of the shell finite-element results obtained in this study with the semiloof thin-shell finite-element results of the University College, London (UCL), exhibits good agreement. Good agreement exists between the results of this study and the UCL parametric equations for the chord and the brace of the joint, with a maximum difference of about 7% on the braceside around the saddle position. Comparisons between the finite-element results and other known parametric equations for stress concentration factor with different diametral, wall thickness, and chord thickness and ratios also show good agreement. A comparison of the results obtained from the finite-element analysis and the experimental results of the Canadian Cooperative Fatigue Studies Program, carried out at Memorial University of Newfoundland and University of Waterloo, is also made. Key words: stress distribution, finite-element analysis, stress concentration factors, membrane stress, bending stress, tubular T-joints.


2015 ◽  
Vol 40 (4) ◽  
pp. E158-E166 ◽  
Author(s):  
ACO Souza ◽  
TA Xavier ◽  
JA Platt ◽  
ALS Borges

SUMMARY The purpose of this study was to evaluate the influence of direct base and indirect inlay materials on stress distribution and fracture resistance of endodontically treated premolars with weakened cusps. Forty healthy human premolars were selected; five were left intact as controls (group C+), and the others were subjected to endodontic treatment and removal of buccal and lingual cusp dentin. Five teeth were left as negative controls (group C−). The remaining 30 teeth were divided into two groups according to the direct base material (glass ionomer [GIC] or composite resin [CR]). After base placement, each group was subjected to extensive inlay preparation, and then three subgroups were created (n=5): no inlay restoration (GIC and CR), restored with an indirect composite resin inlay (GIC+IR and CR+IR), and restored with a ceramic inlay (GIC+C and CR+C). Each specimen was loaded until fracture in a universal testing machine. For finite element analysis, the results showed that the removal of tooth structure significantly affected fracture resistance. The lowest values were presented by the negative control group, followed by the restored and based groups (not statistically different from each other) and all lower than the positive control group. In finite element analysis, the stress concentration was lower in the restored tooth compared to the tooth without restoration, whereas in the restored teeth, the stress concentration was similar, regardless of the material used for the base or restoration. It can be concluded that the inlay materials combined with a base showed similar behavior and were not able to regain the strength of intact tooth structure.


2021 ◽  
Vol 24 (3) ◽  
Author(s):  
Laura Célia Fernandes Meirelles ◽  
Fernanda Zapater Pierre ◽  
João Paulo Mendes Tribst ◽  
Clovis Pagani ◽  
Eduardo Bresciani ◽  
...  

Objective: Evaluate the effect of four preparation designs, two ceramic materials, and two occlusion contact types on the stress distribution of ceramic veneer in upper central incisor. Material and methods:  3D-models were performed in the modeling software containing enamel, dentin, pulp, periodontal ligament and a base of polyurethane resin. The designs were modeled and exported to the computer aided engineering software to perform the static structural analysis. For the mesh, a total of 155429 tetrahedron elements and 271683 nodes were used, after a 10% convergence test. Two materials, lithium disilicate and feldspathic ceramics, were simulated. A static load of 100 N on 45º was applied on the incisal and middle thirds of the palatal tooth region, guided by the occlusal plane. The base was constrained in all directions. The Maximum Principal Stress was the failure criteria chosen for the analysis. Results: The Finite Element Analysis showed that the most conservative designs presented less stress concentration on the ceramic veneer. However, the highest tensile stress concentrations were observed on lithium disilicate veneer with extend design, on the middle third. The type of occlusal contact presented different stress patterns among the preparation designs; the incisal contact showed higher stress concentration compared to middle third contact regardless the ceramic material. Conclusions: To perform a ceramic veneer in upper central incisor, the feldspathic ceramic presented promising results and should be recommended when the extended design was done. Regarding contact types, the incisal contact is more prone to failure regardless the ceramic and preparation design.   Keywords Ceramics; Dental veneers; Finite element analysis.


2014 ◽  
Vol 577 ◽  
pp. 668-672
Author(s):  
Jia Ying Zhang ◽  
Gang Zhao ◽  
Hua Dong Ding ◽  
Ye Wang Sun ◽  
Jun Wei Yang

The process of bonding strength measuring of revolution body coating was emulated by ANSYS. The stress curves with different substrate radiuses of coating bonding interface were drawn. Analyzing the results, and comparing the results with the measuring results of FeAlCrBSiNb in 20mm radius of revolution body and plane coating in the same process and material, they coincided with the finite element analysis results well. Analyzing the errors in the process of bonding strength measuring of revolution body coating, the optimized scheme of measuring model was proposed.


Author(s):  
Saeed Nokar ◽  
Hamid Jalali ◽  
Farideh Nozari ◽  
Mahnaz Arshad

Objectives: The success of implant treatment depends on many factors affecting the bone-implant, implant-abutment, and abutment-prosthesis interfaces. Stress distribution in bone plays a major role in success/failure of dental implants. This study aimed to assess the pattern of stress distribution in bone and abutment-implant interface under static and cyclic loadings using finite element analysis (FEA). Materials and Methods: In this study, ITI implants (4.1×12 mm) placed at the second premolar site with Synocta abutments and metal-ceramic crowns were simulated using SolidWorks 2007 and ABAQUS software. The bone-implant contact was assumed to be 100%. The abutments were tightened with 35 Ncm preload torque according to the manufacturer’s instructions. Static and cyclic loads were applied in axial (116 Ncm), lingual (18 Ncm), and mesiodistal (24 Ncm) directions. The maximum von Mises stress and strain values ​​were recorded. Results: The maximum stress concentration was at the abutment neck during both static and cyclic loadings. Also, maximum stress concentration was observed in the cortical bone. The loading stress was higher in cyclic than static loading. Conclusion: Within the limitations of this study, it can be concluded that the level of stress in single-unit implant restorations is within the tolerable range by bone.


Sign in / Sign up

Export Citation Format

Share Document