In this paper, ANSYS-LSDYNA simulation software is used to build the three-dimensional finite element model of the ball bond and to get the Von Mises stress. The change of stress about the bump is researched which base on the model in different bonding pressure, bonding power and bonding time. The result show that: The stress increase with bonding pressure increase within a certain bonding pressure range, and then the stress will maintain a table number, however, the stress will continue to increase when the bonding pressure reach a certain value; increasing the bonding power, the area of lager stress will grow; prolonging the bonding time, the stress of the pad will increase with time, but when time increase to a certain value, the stress of the pad will not increase over time.

2013 ◽  
Vol 405-408 ◽  
pp. 1139-1143
Author(s):  
Wei Su ◽  
Ying Sun ◽  
Shi Qing Huang ◽  
Ren Huai Liu

Using ANSYS parametric design language, a three-dimensional finite element model is developed to analyze the stress distribution and the strength of the mega columns for XRL West Kowloon Terminus. The detailed von Mises stress distribution in each column, vertical stiffener plates and the diaphragm plates is obtained. From the analysis, the phenomenon of stress concentration is obvious in both upper and lower diaphragm plates. The local value of von Mises stress in them is higher than the yield stress value, which must be avoided by more detailed local structural design.


Author(s):  
Yuan-Jian Yang ◽  
Liang Yang ◽  
Hai-Kun Wang ◽  
Shun-Peng Zhu ◽  
Hong-Zhong Huang

AbstractTurbine blades are one of the key components in a typical turbofan engine, which plays an important role in flight safety. In this paper, we establish a establishes a three-dimensional finite element model of the turbine blades, then analyses the strength of the blade in complicated conditions under the joint function of temperature load, centrifugal load, and aerodynamic load. Furthermore, contact analysis of blade tenon and dovetail slot is also carried out to study the stress based on the contact elements. Finally, the Von Mises stress-strain distributions are obtained to acquire the several dangerous points and maximum Von Mises stress, which provide the basis for life prediction of turbine blade.


2020 ◽  
Vol 28 (6) ◽  
pp. 603-613 ◽  
Author(s):  
Efe Can Sivrikaya ◽  
Mehmet Sami Guler ◽  
Muhammed Latif Bekci

BACKGROUND: Zirconia has become a popular biomaterial in dental implant systems because of its biocompatible and aesthetic properties. However, this material is more fragile than titanium so its use is limited. OBJECTIVES: The aim of this study was to compare the stresses on morse taper implant systems under parafunctional loading in different abutment materials using three-dimensional finite element analysis (3D FEA). METHODS: Four different variations were modelled. The models were created according to abutment materials (zirconia or titanium) and loading (1000 MPa vertical or oblique on abutments). The placement of the implants (diameter, 5.0 × 15 mm) were mandibular right first molar. RESULTS: In zirconia abutment models, von Mises stress (VMS) values of implants and abutments were decreased. Maximum and minimum principal stresses and VMS values increased in oblique loading. VMS values were highest in the connection level of the conical abutments in all models. CONCLUSIONS: Using conical zirconia abutments decreases von Mises stress values in abutments and implants. However, these values may exceed the pathological limits in bruxism patients. Therefore, microfractures may be related to the level of the abutment.


2013 ◽  
Vol 07 (04) ◽  
pp. 484-491 ◽  
Author(s):  
Wagner Moreira ◽  
Caio Hermann ◽  
Jucélio Tomás Pereira ◽  
Jean Anacleto Balbinoti ◽  
Rodrigo Tiossi

ABSTRACT Objective: The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Materials and Methods: Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). Results: The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Conclusions: Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.


Author(s):  
Mateus Favero Barra Grande ◽  
Marcelo Lucchesi Teixeira ◽  
André Antônio Pelegrine ◽  
Guilherme Da Rocha Scalzer Lopes ◽  
Julio Ferraz Campos ◽  
...  

The effect of the different dental implants positioning region on the stress performance of the implant-supported prosthesis is not yet clear. This study evaluated the dental treatment with six dental implants in three different models and three different occlusal loading conditions, in terms of the biomechanical response of implants, prosthetic screw and maxilla, using three-dimensional finite element analysis. The finite element models were modelled containing external hexagon implants, as well as a Cobalt-Chromium superstructure. Three types of loads were applied: in the area of ​​the central incisors, first premolar and in the second molars. For the finite element simulations, the von-Mises stress peaks in the implant and in the surrounding cortical bone were analyzed. All recorded results reported higher values ​​for the implant-supported prosthesis in group C compared to the groups A and B. The highest stress values, ​​regardless the evaluated model, was in the prosthesis in group C and in screws, the smallest were in group A.


Materials ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2666
Author(s):  
Jae-Hyun Lee ◽  
Ho Yeol Jang ◽  
Su Young Lee

The present study was designed to compare the stress distributions in two restoration types of implants and the surrounding bone. The first restoration type was a conventional cement-retained zirconia crown, and the second was a novel cementless screw-retained zirconia crown with a base abutment. A three-dimensional finite element method was used to model the implants, restorations, and supporting bone. A comparative study of the two implants was performed under two masticatory loads: a vertical load of 100 N and a 30-degree oblique load of 100 N. Under both loading conditions, the maximum von Mises stress and strain values in the implant and supporting bone were higher in the conventional cement-retained restoration model than in the cementless screw-retained model. In terms of stress distribution, the cementless screw-retained zirconia crown with base abutment may be considered a superior restoration option compared to the conventional cement-retained zirconia crown.


2012 ◽  
Vol 197 ◽  
pp. 93-97 ◽  
Author(s):  
Wen Zhi Zhao ◽  
Hong Jiang ◽  
Sheng Wei He ◽  
Lu Zhang ◽  
Xue Gang Sun

A three-dimensional finite element model is developed to simulate the integrated system which consists of the fractured bone (femur), bone plate and stabilization screw by using the ANSYS software. The stress and strain distribution of the integrated system is investigated. The numerical model simulates a patient’s imperfect walking under the assumption that the fractured bone is not able to support any load and all body weight was burden by bone plate in fractured bone section. The simulation results reveal that the maximum Von Mises stress on bone plate is much less than yield strength and fatigue strength of Titanium alloy.


2020 ◽  
Vol 46 (1) ◽  
pp. 3-12
Author(s):  
Ji-Hyeon Oh ◽  
Young-Seong Kim ◽  
Joong Yeon Lim ◽  
Byung-Ho Choi

The all-on-4 concept, which is used to rehabilitate edentulous patients, can present with mechanical complications such as screw loosening and fracture. The purpose of this study was to evaluate the stress patterns induced in the prosthetic screws by the different prosthetic screw and abutment designs in the all-on-4 concept using finite element analysis. Von Mises stress values on 6 groups of each screw type, including short and narrow screw, short abutment; short and wide screw, short abutment; long and wide screw, short abutment; short and narrow screw, long abutment; short and wide screw, long abutment; and long and wide screw, long abutment, were compared under a cantilever loading of 200 N that was applied on the farther posterior to the position of the connection between the distal implant and the metal framework. Posterior prosthetic screws showed higher stress values than anterior prosthetic screws. The stress values in posterior prosthetic screws decreased as the length and diameter increased. In conclusion, the long and wide screw design offers advantages in stress distribution when compared with the short and narrow design.


2015 ◽  
Vol 41 (2) ◽  
pp. 163-171 ◽  
Author(s):  
Gianpaolo Sannino

The aim of this work was to study the biomechanical behavior of an All-on-4 implant-supported prosthesis through a finite element analysis comparing 3 different tilt degrees of the distal implants. Three-dimensional finite element models of an edentulous maxilla restored with a prosthesis supported by 4 implants were reconstructed to carry out the analysis. Three distinct configurations, corresponding to 3 tilt degrees of the distal implants (15°, 30°, and 45°) were subjected to 4 loading simulations. The von Mises stresses generated around the implants were localized and quantified for comparison. Negligible differences in von Mises stress values were found in the comparison of the 15° and 30° models. From a stress-level viewpoint, the 45° model was revealed to be the most critical for peri-implant bone. In all the loading simulations, the maximum stress values were always found at the neck of the distal implants. The stress in the distal implants increased in the apical direction as the tilt degree increased. The stress location and distribution patterns were very similar among the evaluated models. The increase in the tilt degree of the distal implants was proportional to the increase in stress concentration. The 45° model induced higher stress values at the bone-implant interface, especially in the distal aspect, than the other 2 models analyzed.


2018 ◽  
Vol 32 (4) ◽  
pp. 185
Author(s):  
Josué Ricardo Broilo ◽  
Evandro Afonso Sartori ◽  
Luiz Oscar Honorato Mariano ◽  
Leandro Corso ◽  
Rosemary Sadami Arai Shinkai

OBJECTIVE: This 3-D FEA study compared the stress distribution in two-implant mandibular overdentures as a function of implant position and attachment system (LA: locator attachment vs. BA: ball attachment).METHODS: Four models of mandibular overdentures were tested: M1-LA – with implants at the canine regions (standard implant position) and LA; M2-LA – with implants placed at the first premolar regions (distalized implant position) and LA; M1-BA – with standard implant position and BA; and M2-BA – with distalized implant position and BA. The geometric models were converted into finite element models. A 100 N axial load was applied at the first molar region. The von-Mises stress distribution was compared in selected points.RESULTS: The models with BA had pattern of stress distribution was more uniform along the implant axis than the ones with LA, although the stress magnitude was larger. The largest area of von Mises stresses on the alveolar ridge was in the models with standard implant distribution.CONCLUSION: The findings showed that the models with BA had better biomechanical behavior than the ones with LA. For both types of attachment, the models with increased inter-implant distance presented a smaller area of stress distribution in the perimplant cortical bone tissue than the standard implant position. 