The Study and Application of the Nitrile Gloves’ Production Line’s Online Measurement

2015 ◽  
Vol 727-728 ◽  
pp. 804-808
Author(s):  
Jian Jun Cai ◽  
Jian Bing Han ◽  
Su Qin Qu

In order to solve the problem of the hand module’s online temperature measurement in Nitrile glove production line process, we have developed a set of moving objects or device used for online temperature measurement. The device is mounted infrared temperature sensor, by using PLC-controlled synchronous tracking technology it can track the hand module in the production line, so it can ensure the infrared temperature sensor and hand module synchronously measure its temperature correctly. By using configuration software kingview, we have developed mold temperature monitoring online measurement interface, real-time monitoring of the mold temperature opponents. After analysis of experimental results we concluded that the device work stable, acquisition of temperature reliably, so it has a promotional value.

2016 ◽  
Vol 11 (4) ◽  
pp. 324
Author(s):  
Nor Nadirah Abdul Aziz ◽  
Yasir Mohd Mustafah ◽  
Amelia Wong Azman ◽  
Amir Akramin Shafie ◽  
Muhammad Izad Yusoff ◽  
...  

2018 ◽  
Author(s):  
Anna Adams ◽  
Radha Krishna Murthy Bulusu ◽  
Nikita Mukhitov ◽  
Jose Mendoza-Cortes ◽  
Michael Roper

In this work, we developed a microfluidic bioreactor for optimizing growth and maintaining structure and function of HepG2, and when desired, the device could be removed and the extracellular output from the bioreactor combined with enzymatic glucose reagents into a droplet-based microfluidic system. The intensity of the resulting fluorescent assay product in the droplets was measured, and was directly correlated to glucose concentration, allowing the effect of insulin on glucose consumption in the HepG2 cells to be observed and quantified online and in near real-time.


2018 ◽  
Author(s):  
Anna Adams ◽  
Radha Krishna Murthy Bulusu ◽  
Nikita Mukhitov ◽  
Jose Mendoza-Cortes ◽  
Michael Roper

In this work, we developed a microfluidic bioreactor for optimizing growth and maintaining structure and function of HepG2, and when desired, the device could be removed and the extracellular output from the bioreactor combined with enzymatic glucose reagents into a droplet-based microfluidic system. The intensity of the resulting fluorescent assay product in the droplets was measured, and was directly correlated to glucose concentration, allowing the effect of insulin on glucose consumption in the HepG2 cells to be observed and quantified online and in near real-time.


2020 ◽  
Vol 315 ◽  
pp. 112341
Author(s):  
Zhaojun Liu ◽  
Bian Tian ◽  
Xu Fan ◽  
Jiangjiang Liu ◽  
Zhongkai Zhang ◽  
...  

Author(s):  
Jyh Chen ◽  
Jin-Tu Huang ◽  
Hsing-Chin Yeh ◽  
Chean-Mean Chen ◽  
Yen-Tseng Hsu

Sign in / Sign up

Export Citation Format

Share Document