The Reliability Research of Steel Plate Shear Wall Based on APDL

2011 ◽  
Vol 368-373 ◽  
pp. 885-888
Author(s):  
Hui Rong Huang ◽  
Yi Jie Zhu ◽  
Jia Yuan Guo ◽  
Xiao Yuan Feng

Abstract: The models of un-stiffened, cross stiffened and diagonal stiffened are established by the APDL language of ANSYS, then their reliabilities of stochastic finite element are researched. The result shows that, under the equal seismic forces, the reliability of the three models from childhood in order as is the un-stiffened, the cross stiffened and the diagonal stiffened. And the vertical pressure is the most effective factor toward the three models. Recently years, the study about the steel plate shear wall at home and abroad is almost the research [1,2] of experience and hysteretic performance by the theory combined with experiences. Xianzeng Li [3], who discussed the feasibility of thin steel plate shear wall which is used in the seismic area, studied the stress structure feature and seismic feature of the thin steel plate shear wall under the drab and cyclic loads by finite element. The shear performance under one-way load and the hysteretic performance of the diagonal stiffened were researched deeply by Chunhua Cao [4,5], and the result shows that it’s an excellent part of resisting lateral force with full stability lag circle and high security reserve. In this text, the analysis about the reliability of steel plate spear wall is completed.

2019 ◽  
Vol 803 ◽  
pp. 314-321 ◽  
Author(s):  
Maryam Bypour ◽  
Benyamin Kioumarsi ◽  
Mahdi Kioumarsi

In this paper, the behavior of steel plate shear wall (SPSW) in the reinforced concrete frame (RCF) has been studied numerically. Three different connections have been proposed to connect SPSW to RCF. In the first connection, fish plates, while in the second one, combination of fish plates and studs transfer forces between SPSW and RCF. In the third connection, there is no direct connection between the infill plate and RCF, and additional steel frame has been used for connecting of the infill plate. The results demonstrate that, load carrying capacity increases in all the specimens comparing the reference RCF. Investigating the formation sequence of plastic hinges in different specimens demonstrates that there is different sequence in the specimens with different connections.


2018 ◽  
Vol 151 ◽  
pp. 194-203 ◽  
Author(s):  
Yipeng Du ◽  
Jiping Hao ◽  
Jinguang Yu ◽  
Haisheng Yu ◽  
Bowen Deng ◽  
...  

2021 ◽  
pp. 136943322110542
Author(s):  
Mahdi Usefvand ◽  
Ahmad Maleki ◽  
Babak Alinejad

Coupled steel plate shear wall (C-SPSW) is one of the resisting systems with high ductility and energy absorption capacity. Energy dissipation in the C-SPSW system is accomplished by the bending and shear behavior of the link beams and SPSW. Energy dissipation and floor displacement control occur through link beams at low seismic levels, easily replaced after an earthquake. In this study, an innovative coupled steel plate shear wall with a yielding FUSE is presented. The system uses a high-ductility FUSE pin element instead of a link beam, which has good replaceability after the earthquake. In this study, four models of coupled steel plate shear walls were investigated with I-shaped link beam, I-shaped link beam with reduced beam section (RBS), box-link beam with RBS, and FUSE pin element under cyclic loading. The finite element method was used through ABAQUS software to develop the C-SPSW models. Two test specimens of coupled steel plate shear walls were validated to verify the finite element method results. Comparative results of the hysteresis curves obtained from the finite element analysis with the experimental curves indicated that the finite element model offered a good prediction of the hysteresis behavior of C-SPSW. It is demonstrated in this study that the FUSE pin can improve and increase the strength and energy dissipation of a C-SPSW system by 19% and 20%, respectively.


2012 ◽  
Vol 06 (01) ◽  
pp. 1250004 ◽  
Author(s):  
SWAPNIL B. KHARMALE ◽  
SIDDHARTHA GHOSH

The thin unstiffened steel plate shear wall (SPSW) system has now emerged as a promising lateral load resisting system. Considering performance-based design requirements, a ductility-based design was recently proposed for SPSW systems. It was felt that a detailed and closer look into the aspect of seismic lateral force distribution was necessary in this method. An investigation toward finding a suitable lateral force distribution for ductility-based design of SPSW is presented in this paper. The investigation is based on trial designs for a variety of scenarios where five common lateral force distributions are considered. The effectiveness of an assumed trial distribution is measured primarily on the basis of how closely the design achieves the target ductility ratio, which is measured in terms of the roof displacement. All trial distributions are found to be almost equally effective. Therefore, the use of any commonly adopted lateral force distribution is recommended for plastic design of SPSW systems.


1999 ◽  
Vol 26 (5) ◽  
pp. 549-563 ◽  
Author(s):  
A Schumacher ◽  
G Y Grondin ◽  
G L Kulak

The behaviour under cyclic loading of unstiffened steel plate shear wall panels at their connection to the bounding beams and columns was investigated on full-size panel corner details. Four different infill panel connection details were tested to examine and compare their response to quasi-static cyclic loading. The load versus displacement response of the details showed gradual and stable deterioration at higher loads. The formation of tears in the connection details did not result in a loss of load-carrying capacity. In addition to the experimental program, a finite element model was developed to model the behaviour of one of the infill plate corner connection specimens. Results from the analysis showed that the finite element method can be used to obtain the load versus displacement behaviour of an infill panel-to-boundary member arrangement.Key words: cyclic loading, hysteresis, shear wall, steel, welded connection.


2013 ◽  
Vol 671-674 ◽  
pp. 1408-1413
Author(s):  
Ning Zhou ◽  
Feng Xiong ◽  
Qun Yi Huang ◽  
Qi Ge ◽  
Jiang Chen

Composite steel plate shear wall (CSPSW), as a new lateral force resisting structure composed of steel plate and concrete slab, is introduced. CSPSWs can fully display the superiority of the steel plate and concrete. Ductility and energy dissipation capacity of the walls are increased and seismic behavior is improved. Recent seismic research around the word of two kinds of CSPSWs, namely, CSPSW with signal steel plate and CSPSW with double steel plates, is presented and discussed comprehensively. Some existing problems in current research of the walls are also reviewed in this paper.


2014 ◽  
Vol 501-504 ◽  
pp. 563-567
Author(s):  
Zong Jing Li ◽  
Gan Ping Shu

When steel plate shear walls (SPSWs) are fitted into a long-span truss system, horizontal and vertical deformation should both be considered to evaluate the seismic performance of the structure. Numerical analysis is conducted to study the seismic performance of stiffened steel plate shear wall with opening subject to horizontal and vertical loading respectively based on a project. Results of the analysis indicate that stress distribution and deformation patterns of SPSW with opening are quite similar under horizontal and vertical loading. Stiffeners around the opening should be stretched to full height or width of the SPSW and strengthened by using larger thickness or width. The grids at the four corners of the opening are recommended to be further strengthened by additional stiffeners. SPSW with opening exhibits good hysteretic performance and energy dissipation in both loading directions.


Sign in / Sign up

Export Citation Format

Share Document