Numerical Simulation of Thermal Comfort Performance in a Room with Different Insulating Materials Using Computational Fluid Dynamics

2015 ◽  
Vol 650 ◽  
pp. 29-37
Author(s):  
A. Aravind Kumar ◽  
B. Nagesh Babu ◽  
S. Somya

Numerical simulation studies are carried out for improvement of energy efficiency in a room by with different thermal insulating materials using computational fluid dynamics (CFD). The study considered various building insulating materials (BIM’s) such as: (a) Expanded Polystyrene (EPS) (b) Fiber Glass (Resin bonded (RB)-Glass wool) (c) Polyurethane Foam (PUF) and (d) Cement Plaster (CP) along with composite bricklayer combination. A multi-physical 3D model room of size 2.6 m × 2.6 m × 2.6 m is created to analyze the performance of different insulating materials using CFD simulations. The experimental data of 24 hr temperature cycle of the ambient air is used for the analysis of performance of thermal comfort inside the room with the incorporation of different thickness of the insulating materials. The thickness of insulation 0.03, 0.1, 0.2 and 0.3 m is applied on interior side of walls and roof of the building. The study performed with different grid sensitiveness for coarse, medium and fine meshes for the improvement in the accuracy of the results. The fine grid mesh analysis is chosen to carry the further studies to compare the insulated and non-insulated condition for the thermal behavior inside the room. The result shows that the thermal conductivity and heat capacity of insulated walls are very important to be taken into account for carrying out detailed thermal analysis of buildings. The studies are carried out using commercial CFD tool of ANSYS CFX 15.0. The results of comparison shows that it is possible to maintain needed thermal comfort conditions in the room while reducing the total energy consumptions at the same time by appropriate use of BIM’s.

Author(s):  
Mayank Rakesh ◽  
Paritosh Kumar Rakesh ◽  
Brajesh Kumar ◽  
Satajit Chowdhury ◽  
Atul Kumar Patidar

2014 ◽  
Vol 493 ◽  
pp. 74-79
Author(s):  
Y.A. Sabtalistia ◽  
S.N.N. Ekasiwi ◽  
B. Iskandriawan

Energy consumption for air conditioning systems (air conditioning system) increased along with the increasing need for fresh air and comfortable in the room especially apartments. FAC system (Floor Air Conditioning) is growing because it is more energy efficient than CAC (Ceiling Air Conditioning) system. However, the position of the AC supply is on the lower level at the FAC system causes draft discomfort becomes greater as air supply closer to the occupants so that thermal comfort can be reduced. Heat mixture of windows, exterior walls, kitchen, and occupants in the studio apartment affect thermal comfort in the room too.This study aims to determine the position of the AC supply which has the best thermal comfort of FAC system in the studio apartment. It can be done by analyzing ADPI (Air Diffusion Performance Index), the distribution of air temperature, wind speed, RH (Relative Humidity), and DR (Draft Risk) to change the position of the AC supply supported by CFD (Computational Fluid Dynamics) simulation.This result prove that AC position 2 (on wall near the kitchen) is more comfortable than AC position 1 (on the bathroom wall) because AC position 2 away from occupied areas, thereby reducing the occurrence of draught discomfort.


2012 ◽  
Vol 3 ◽  
pp. 366-374
Author(s):  
Jarosław Wasilewski ◽  
Kryspin Mirota ◽  
Sylwia Peryt-Stawiarska ◽  
Andrzej Nowakowski ◽  
Lech Poloński ◽  
...  

2014 ◽  
Vol 687-691 ◽  
pp. 679-683 ◽  
Author(s):  
Jun Zhang ◽  
Yong Wu ◽  
Hong Mei Tang ◽  
Chun Ren Tang ◽  
Xian Hua Li

The oil spill will directly affect the measuring accuracy of the gear flowmeter, so use the computational fluid dynamics software to calculate the leakage regulation of the internal gear flowmeter is one of the important things. Based on Pumplinx, when the end clearances of the gear flowmeter were 0um, 10um, 20um, 30um, 40um and 50um, the corresponding numerical analysis of spillage was carried out. From the results of numerical analysis, with the increase of the end clearance, the leakage amplification will also increase. In practical work, we should control the end clearance of gear flowmeter strictly while the gear works normally.