scholarly journals Diagnostic values of shear wave elastography and strain elastography for breast lesions

2020 ◽  
Vol 148 (9) ◽  
pp. 1239-1245
Author(s):  
Huiwen Jiang ◽  
Xiaodan Yu ◽  
Lina Zhang ◽  
Linxiao Song ◽  
Xiuhua Gao
Author(s):  
Vito Cantisani ◽  
Emanuele David ◽  
Richard G. Barr ◽  
Maija Radzina ◽  
Valeria de Soccio ◽  
...  

Abstract Purpose To evaluate the diagnostic performance of strain elastography (SE) and 2 D shear wave elastography (SWE) and SE/SWE combination in comparison with conventional multiparametric ultrasound (US) with respect to improving BI-RADS classification results and differentiating benign and malignant breast lesions using a qualitative and quantitative assessment. Materials and Methods In this prospective study, 130 histologically proven breast masses were evaluated with baseline US, color Doppler ultrasound (CDUS), SE and SWE (Toshiba Aplio 500 with a 7–15 MHz wide-band linear transducer). Each lesion was classified according to the BIRADS lexicon by evaluating the size, the B-mode and color Doppler features, the SE qualitative (point color scale) and SE semi-quantitative (strain ratio) methods, and quantitative SWE. Histological results were compared with BIRADS, strain ratio (SR) and shear wave elastography (SWE) all performed by one investigator blinded to the clinical examination and mammographic results at the time of the US examination. The area under the ROC curve (AUC) was calculated to evaluate the diagnostic performance of B-mode US, SE, SWE, and their combination. Results Histological examination revealed 47 benign and 83 malignant breast lesions. The accuracy of SR was statistically significantly higher than SWE (sensitivity, specificity and AUC were 89.2 %, 76.6 % and 0.83 for SR and 72.3 %, 66.0 % and 0.69 for SWE, respectively, p = 0.003) but not higher than B-mode US (B-mode US sensitivity, specificity and AUC were 85.5 %, 78.8 %, 0.821, respectively, p = 1.000). Conclusion Our experience suggests that conventional US in combination with both SE and SWE is a valid tool that can be useful in the clinical setting, can improve BIRADS category assessment and may help in the differentiation of benign from malignant breast lesions, with SE having higher accuracy than SWE.


Diagnostics ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1015
Author(s):  
Antonio Bulum ◽  
Gordana Ivanac ◽  
Eugen Divjak ◽  
Iva Biondić Špoljar ◽  
Martina Džoić Dominković ◽  
...  

Shear wave elastography (SWE) is a type of ultrasound elastography with which the elastic properties of breast tissues can be quantitatively assessed. The purpose of this study was to determine the impact of different regions of interest (ROI) and lesion size on the performance of SWE in differentiating malignant breast lesions. The study included 150 female patients with histopathologically confirmed malignant breast lesions. Minimal (Emin), mean (Emean), maximal (Emax) elastic modulus and elasticity ratio (e-ratio) values were measured using a circular ROI size of 2, 4 and 6 mm diameters and the lesions were divided into large (diameter ≥ 15 mm) and small (diameter < 15 mm). Highest Emin, Emean and e-ratio values and lowest variability were observed when using the 2 mm ROI. Emax values did not differ between different ROI sizes. Larger lesions had significantly higher Emean and Emax values, but there was no difference in e-ratio values between lesions of different sizes. In conclusion, when measuring the Emin, Emean and e-ratio of malignant breast lesions using SWE the smallest possible ROI size should be used regardless of lesion size. ROI size has no impact on Emax values while lesion size has no impact on e-ratio values.


2015 ◽  
Vol 38 (01) ◽  
pp. 51-59 ◽  
Author(s):  
Alexandra Athanasiou ◽  
Heldmuth Latorre-Ossa ◽  
Aline Criton ◽  
Anne Tardivon ◽  
Jean-Luc Gennisson ◽  
...  

2021 ◽  
Vol 47 (1) ◽  
pp. 95-103
Author(s):  
Seung Hee Choi ◽  
Eun Young Ko ◽  
Boo-Kyung Han ◽  
Eun Sook Ko ◽  
Ji Soo Choi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document