scholarly journals A challenging case of tracheal foreign body retrieval following COVID-19 swabbing

Author(s):  
James May ◽  
Katrina Mason ◽  
Parag Patel ◽  
Brendan Madden

The COVID-19 pandemic has resulted in a significant increase in the number of tracheostomised patients in hospitals requiring ventilatory support. These patients require highly specialist care, but overwhelmed hospital systems with stretched human resources potentially leave these patients cared for by undertrained healthcare professionals. We describe a rare complication where a routine COVID-19 swab done incorrectly via a tracheostomy tube, resulted in a snapped-off swab in the trachea. We outline the events and our method of removal using rigid bronchoscopy through the tracheostomy stoma as endo-tracheal bronchoscopy was impossible due to significant sub-glottic stenosis. This case highlights the paramount importance of the unique care needed to safely manage tracheostomies during this ongoing pandemic.

2015 ◽  
Vol 81 (4) ◽  
pp. 345-348
Author(s):  
Matthew L. Stone ◽  
Johnd Tillou ◽  
Christophera Guidry ◽  
Sarak Rasmussen ◽  
Bartholomew J. Kane ◽  
...  

The purpose of this study was to evaluate the usefulness of chest radiography in the direction of postbronchoscopy clinical therapy. From 2001 to 2011, 368 rigid bronchoscopies were performed at a single institution in 221 children. Indications for bronchoscopy, concomitant bronchoscopic procedures, and results of postoperative chest radiography were evaluated. Rigid bronchoscopy was performed in children at a median age of 2.21 years (range, two days to 20 years). Chest radiography was performed at the discretion of the primary surgeon after 275 (74.7%) procedures. Malpositioning of the endotracheal or tracheostomy tube occurred in 1.5 per cent (n = three of 203) of ventilated patients postbronchoscopy. Pneumothorax occurred in 0.5 per cent (n = two of 368) of children and followed laser degranulation (n = one of 117 [0.9%]) and removal of an aspirated foreign body (n = one of 80 [1.3%]). Neither child required tube thoracostomy. Three children necessitated intraoperative tube thoracostomy placement for symptomatic pneumothoraces before radiographic assessment. No children sustained postprocedural complications in the absence of postbronchoscopy radiography. Postbronchoscopy chest radiography in the absence of defined symptomatology is not associated with a change in the postprocedural treatment course, suggesting selective application may be appropriate after at-risk bronchoscopic interventions. Such practice will limit the future cost and radiation exposure associated with this common procedure.


2013 ◽  
Vol 11 (8) ◽  
pp. 635
Author(s):  
Zaid Awad ◽  
Alexander Yao ◽  
Khalid Ghufoor ◽  
Neil Tolley ◽  
Paul Ziprin ◽  
...  

BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Weigang Gan ◽  
Ning Xiao ◽  
Yiyuan Feng ◽  
Danmei Zhou ◽  
Juanjuan Hu ◽  
...  

Abstract Background Tracheobronchial foreign body aspiration (TFBA) is a critical disease in children and is extremely dangerous, even life-threatening. The factors affecting the occurrence and prognosis of TFBA are complex. The purpose of this study is to examine the external and intrinsic factors affecting clinical features of TFBA in West China and propose potential effective intervention measures. Methods We retrospectively analyzed the clinical data of pediatric patients diagnosed with TFBA with foreign bodies (FBs) removed by rigid bronchoscopy under general anesthesia at the otolaryngology department from December 2017 to November 2018. The data included age, sex, clinical symptoms, type and location of FB, guardians, prehospital duration and residence of these pediatric patients. Results The ratio of males (72) to females (53) was 1.4:1. Children aged from 1 to 3 years accounted for 76% (95/125) of patients. Cough, continuous fever and dyspnea were the primary symptoms. The right primary bronchus was the most common location of FB detection by rigid bronchoscopy (67 cases, 53.6%). Organic FBs were most common in our study. Guardians of patients significantly differed in the rural (parents 16, grandparents 31) and urban (parents 52, grandparents 26) groups (χ2 = 12.583, p = 0.000). More children in the rural group than in the urban group had a treatment delay longer than 72 h. More children in the group with no history of FB aspiration (12, 25%) than in the group with prior FB aspiration had a treatment delay longer than 72 h. Conclusion Pediatric TFBA is a common emergency in otolaryngology. Age, sex, tracheobronchial anatomy and other physiological elements were defined as intrinsic factors, while guardians, residence, FB species and prehospital time were defined as external factors of TFBA. External and intrinsic factors both influence the occurrence and progression of TFBA. It is extremely important to take effective measures to control external factors, which can decrease morbidity and mortality.


Author(s):  
Darwin Kaushal ◽  
Amit Goyal ◽  
Kapil Soni ◽  
Bikram Choudhury ◽  
Nithin Prakasan Nair ◽  
...  

Abstract Introduction Airway foreign bodies are emergencies involving multidisciplinary departments like Pediatrics, Aneasthesiology and Otorhinolaryngology. It is always a challenge to diagnose and manage patients who present late to our emergencies. Objective In the present study, we aim to analyze the various challenges faced during the management of tracheobronchial foreign bodies with delayed presentation. Methods A retrospective hospital record-based analysis of patients who presented to us with tracheobronchial foreign bodies from January 2017 to February 2020 was performed. All patients until the age of 16 years old were included in the present study. We assessed the demographics, preoperative, intraoperative and postoperative data of the patients. Results Seventeen patients were analyzed in the study. Among these, 44.4% of the patients had delayed presentation (> 1 month). The majority of the patients had an organic foreign body (Supari or betel nut). All patients underwent rigid bronchoscopy, followed by optical forceps-assisted removal of the foreign body. A total of 82% of the patients had granulations around the foreign body. Conclusion Management of delayed presentation tracheobronchial foreign body is a big challenge for Otorhinolaryngologists. The key factors for preventing complications in the definitive management of tracheobronchial foreign bodies are preoperative planning, multi-discipline teamwork, surgeon expertise and technique.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jisong Zhang ◽  
Huihui Hu ◽  
Li Xu ◽  
Shan Xu ◽  
Jihong Zhu ◽  
...  

Abstract Background Bronchopleural fistula (BPF) is a relatively rare complication after various types of pulmonary resection. The double-sided mushroom-shaped occluder (Amplatzer device, AD) has been gradually used for BPF blocking due to its reliable blocking effect. We have improved the existing AD implantation methods to facilitate clinical use and named the new approach Sheath-free method (SFM). The aim of the present report was to explore the reliability and advantages of the SFM in AD implantation. Methods We improved the existing implantation methods by abandoning the sheath of the AD and using the working channel of the bronchoscope to directly store or release the AD without general anesthesia, rigid bronchoscopy, fluoroscopy, or bronchography. A total of 6 patients (5 men and 1 woman, aged 66.67 ± 6.19 years [mean ± SD]) had BPF blocking and underwent the SFM in AD implantation. Results AD implantation was successfully performed in all 6 patients with the SFM, 4 persons had a successful closure of the fistula, one person died after few days and one person did not have a successful closure of the fistula. The average duration of operation was 16.17 min (16.17 ± 4.67 min [mean ± SD]). No patients died due to operation complications or BPF recurrence. The average follow-up time was 13.2 months (range 10–17 months). Conclusion We observed that the SFM for AD implantation—with accurate device positioning and a clear field of vision—is efficient and convenient. The AD is effective in BPF blocking, and could contribute to significantly improved symptoms of patients.


2016 ◽  
pp. bcr2015213963 ◽  
Author(s):  
Suman Lata Gupta ◽  
Srinivasan Swaminathan ◽  
Ravivalar Ramya ◽  
Satyen Parida

Author(s):  
Sagar Jawale ◽  
Parthapratim Gupta ◽  
Bharti Kulkarni

<p>Bronchoscopic foreign body removal is a potentially dangerous and challenging procedure in pediatric surgery. bronchoscopy under general anaesthesia is the gold standard of diagnosis and management of foreign body aspiration. A large ventilating channel and better control over the tip of the instrument and cheaper instrument are the merits of rigid bronchoscopy over flexible one. Traditionally a rigid tube alone is used for this purpose which has extreme limitations of vision and it is risky. Foreign body aspiration typically occurs in 6 to 18 month age and the size of glottis is very small at this age. In Indian children who are small and malnourished the large assembly of sheath and telescope mounted forceps does not pass through the glottis. To overcome the limitations of the traditional equipment I designed my own bronchoscopy equipment by my 15 year of experience in bronchoscopy. This type of device is reported for the first time in medical literature and patent is filed for it at Mumbai office.</p><p> </p>


2020 ◽  
Author(s):  
Bo Liu ◽  
Fengxia Ding ◽  
Yong An ◽  
Yonggang Li ◽  
Zhengxia Pan ◽  
...  

Abstract Background: The purpose of our study was to assess the frequency of occult foreign body aspiration (FBA) and to evaluate the diagnostic difficulties and therapeutic methods for these patients. Methods: Between May 2000 and May 2020, 3557 patients with the diagnosis of FBA were treated in our department. Thirty-five patients with occult FBA were included in this study. A retrospective analysis of medical records was performed. Results: Twenty-three male patients (65.7%) and 12 female patients (34.3%) were hospitalized due to occult FBA. The average age was 3.60 years (range 9 months-12 years). Most of the patients were younger than 3 years old (n=25, 71.4%). Coughing (n=35, 100%) and wheezing (n=18, 51.4%) were the main symptoms and signs. All the patients were found to have a FBA under the fiberoptic bronchoscope. The most common organic foreign bodies were peanuts (n=10) and the most common inorganic foreign bodies were pen caps (n=5). The extraction of foreign bodies under rigid bronchoscopy was applied successfully in 34 patients. Only one patient needed a surgical intervention. Conclusions: Occult FBA should always be considered in the differential diagnosis of chronic or recurrent respiratory diseases that are poorly explained, even in the absence of a previous history of aspiration.


Sign in / Sign up

Export Citation Format

Share Document