scholarly journals Radiographs late in the follow up of uncomplicated distal radius fractures: are they worth it? Clinical outcome and financial implications

2012 ◽  
Vol 4 (2) ◽  
pp. 20 ◽  
Author(s):  
Nicholas Eastley ◽  
Randeep Aujla ◽  
Zeeshan Khan

Fractures of the distal radius are common. Displacement can quickly lead to secondary osteoarthritis. Early follow up radiographs are subsequently paramount to facilitate for early attempts at reduction. Developing callus eventually makes this impractical. In the absence of complications we propose that radiographs may become obsolete at the later stages of follow up. We investigate whether clinical deformity, range of wrist movement and grip strength are independent of radiographs taken later than 2 weeks into the follow up of uncomplicated cases. Local cases between May 2009 and December 2011 were reviewed. Devised criteria regulated case selection. Data was collected from radiological software and occupational therapy clinical notes. Fractures were placed in short or term follow up groups dependant on whether they were imaged later than 2 weeks into follow up. T-tests compared our outcomes measures between these groups. 138 cases were included; 77 short term; 61 long term. No cases reported visible clinical deformity. There were no significant differences between grip strength or range of wrist movement for the short and long term groups. No cases required intervention for late displacement. Although complications may justify delayed imaging, our results suggest radiographs late in the follow up of uncomplicated distal radius fractures have no impact on our outcome measures. Further studies are required to confirm this. Financial regulation means any potential benefits from the removal of these unnecessary radiographs should be recognised. Established radiological follow up regimes need to be devised.

2017 ◽  
Vol 22 (04) ◽  
pp. 423-428 ◽  
Author(s):  
Yoshihiro Abe ◽  
Masahiro Suzuki ◽  
Hiromasa Wakita

Background: To assess the surgical results of distal radius fractures with the involvement of a volar rim fragment using the DePuy-Synthes 2.0 mm and 2.4 mm locking plates.Methods: Subjects were six women and one man of average age 57 years (range, 31–83 y) and a mean follow-up period of 9 months (range, 5–19 mo) with AO B3 (volar shearing) distal radius fractures. Time of the procedure, physical examination of wrist range of motion, grip strength compared with the contralateral healthy wrist, and radiographic evaluation (volar tilt, radial inclination, and ulnar variance) were evaluated. The Visual Analog Scale (VAS: 0 points represents no pain, 100 points represents the worst pain possible) and the Quick Disability of the Arm, Shoulder, and Hand questionnaire (QuickDASH, 0 = no disability, 100 = extreme disability) were completed by patients at the final follow-up.Results: The average time of the procedure was 74 min. There were no perioperative complications. Average radiographic measures were: volar tilt, 8°; radial inclination, 23°, and ulnar variance, 0 mm. Wrist range of motion averaged 63° in wrist extension (range, 55–80°) and 55° in wrist flexion (range, 45–65°). Grip strength averaged 81% of the contralateral side at final evaluation (range, 67–100%). The mean QuickDASH score was 3.0 points (range, 0–9.1 points) and the mean VAS for pain was 9.3 at final follow-up.Conclusions: Open reduction internal fixation with the DePuy-Synthes 2.0 mm and 2.4 mm locking plates is an effective means of fixing a distal radius fracture that includes a volar rim fragment without interfering with flexor tendon gliding.


2018 ◽  
Vol 07 (05) ◽  
pp. 358-365
Author(s):  
Schneider Rancy ◽  
Stephanie Malliaris ◽  
Eric Bogner ◽  
Scott Wolfe

Purpose CAGE-DR implant is a novel Food and Drug Administration approved intramedullary fracture fixation device used for distal radius fractures. We examine a series of 22 patients and report the outcomes with this device. Materials and Methods A total of 24 patients with distal radius fractures (8 articular AO type C1/C2; 16 extra-articular AO type A2/A3) underwent open reduction and internal fixation (ORIF) using CAGE-DR implant by a single surgeon. Data including fracture type, angle of displacement, radiographic consolidation, grip strength, wrist range of motion (ROM), patient-rated wrist evaluation (PRWE), and Visual Analog Scale (VAS) pain scores were recorded at time of surgery and at standard follow-up. Results All 24 patients underwent uneventful ORIF. At first follow-up visit (9 days), all patients had full digital ROM (measured as 0 cm tip-to-palm distance). Two patients were lost to follow-up. Eighteen of the remaining 22 patients had sufficient radiographic follow-up and all 18 demonstrated healing. At latest follow-up (mean 9.7 months, range, 3–20), VAS pain scores averaged 0.6 (range, 0–8) and PRWE averaged 12.1 (range, 0–53.5). Grip strength of the operated hand averaged 58 lbs (range, 20–130). ROM included: wrist flexion 73° (50–95), wrist extension 78° (60–110), pronation 77° (60–90), supination 79° (60–90), ulnar deviation 31° (5–45), and radial deviation 17° (10–30). Three patients underwent screw removal to prevent tendon irritation. One patient underwent hardware removal due to prominence on imaging but was asymptomatic. There were otherwise no major complications, including complex regional pain syndrome, in the series to date. Conclusion The CAGE-DR fracture fixation system is a promising alternative to established methods of distal radius internal fixation. This series has a low reported pain score starting immediately postoperatively and a low complication rate. This novel device is a promising option for internal fixation of displaced distal radius fractures with a low complication profile. Level of Evidence This is a level IV, therapeutic study.


Author(s):  
Kastanis G ◽  
Pantouvaki A ◽  
Kapsetakis P ◽  
Spyrantis M ◽  
Magarakis G ◽  
...  

Distal radius fractures (DRF) are the most common type of fractures of the upper extremities with an incidence of 44% of all types of forearm and hand fractures. In unstable DRF, the aim of surgical treatment is to restore a functional wrist. Volar locking plate is supported in literature as a promising surgical method in treatment of these fractures. The aim of this study is to analyze the type and complication rate with applied volar locking plate, the percentage of revision surgery and the functional outcomes in a minimum of one year follow up. Material &Methods: 104 fractures in 98 patients with a mean range of 48,5 years-old age underwent for unstable distal radius fractures with volar locking plate. The main cause was simple fall to an outstretched hand. In ten cases the fracture was open while in 28 cases the DRF was accompanied with ulnar styloid. All fractures classified by AO/OTA in A2-3 27 cases, B1-3 in 45 and C1-3 in 32 cases. The majority of patients were operated within 48-72 hours after injury. In all cases an extended flexor carpi radialis approach was performed and a volar locking plate was applied in all DRF’s. In sixteen cases with base of ulnar styloid fractures, low profile locking plates were applied, while in the rest of patients Kirschner wires were used. Postoperatively all patients followed a standard protocol rehabilitation program with passive and active motion of fingers and wrist. Results: Patients were evaluated according to complication (type and rate), time to fracture union, range of motion, Visual analogue pain scale, Quick Dash Score and patients-rated wrist evaluation score. Complications were distinguished in major and minor. Patients under 60 years-old with type fracture A2-3 and B1-3 showed better range of motion and grip strength than patients over 65 years old. In cases with type fractures C1-3 and age over 65 years old, ROM and grip strength decreased compared with the unilateral side. The percentage of complication and reoperation appeared more increased in type C1-3 related to the other two types of fractures. Finally the mean Quick DASH was 11,1±12,8, RPWE was 9.8±13,6 and the range of motion was in extension 75,2±7,3, in flexion 74±8,9, in pronation 85,6±1,9, in supination 88,5±2,4 in radial deviation 9,8±1,2 and in ulnar deviation 41,1±4,6 and grip strength was an average of 84,7% of uninjured hand. Conclusion: Unstable fractures required operative treatment with volar locking plate to be the gold standard in recently years. Unfortunately VPL presents postoperative complications related with plate and screw position with comminuted fracture or soft tissue damage which cannot be ignored, and for these reasons may be inadequate for all types of distal radius fractures.


2017 ◽  
Vol 43 (2) ◽  
pp. 131-136 ◽  
Author(s):  
M. Å. Wadsten ◽  
G. O. Sjödén ◽  
G. G. Buttazzoni ◽  
C. Buttazzoni ◽  
E. Englund ◽  
...  

Late displacement of distal radius fractures, still in acceptable radiological position after 1–2 weeks, occurs in approximately one-third of cases. The aim of this study was to investigate the influence of late displacement on the functional outcome and quality of life at 1 year in non-operatively treated distal radius fractures. One hundred and seventy five unilateral conservatively treated distal radius fractures with minimal displacement after 10–14 days were finally evaluated in the study. Follow-up included radiographs at 3 months and clinical examination 1 year after the fracture. Final radiographic parameters, grip strength, range of motion, QuickDASH, EQ-5D and pain visual analogue scale were evaluated with multivariate analysis. Late displacement occurred in 28% of the cases and was associated with loss of grip strength and range of motion. No significant differences were seen in the outcome questionnaires. Level of evidence: II


2018 ◽  
Vol 23 (02) ◽  
pp. 238-242 ◽  
Author(s):  
Haruhiko Shimura ◽  
Akimoto Nimura ◽  
Koji Fujita ◽  
Takashi Miyamoto

Background: The volar locking plate is frequently used in the fixation of unstable distal radius fractures, but despite this there is a paucity of mid to long term outcome studies. The purpose of this study was to investigate the mid-term functional outcomes of elderly patients treated with a volar locking plate for unstable distal radius fractures. Methods: Thirty-two patients with a mean age of 74.1 (range, 65–85) years were followed for a mean of 39.1 (range, 30–81) months. Patients with follow-up periods of < 24 months were excluded from this study to investigate the mid-term clinical outcomes. The Mayo wrist score (MWS), grip strength and wrist range of motion were retrospectively reviewed at 12 months, 24 months and the latest follow-up (mean 39.1 months). Osteoarthritis status according to the system of Knirk and Jupiter was assessed at 24 months. Results: Significant improvements in MWS and grip strength were observed between 12 and 24 months but not between 24 months and the final follow-up. There was no significant difference in wrist range of motion between 12 and 24 months. The MWS of 14 patients with radiographic signs of osteoarthritis was not significantly different from that of 18 patients without radiographic signs of osteoarthritis. Conclusions: Elderly patients treated with the volar locking plate showed improved MWS and grip strength postoperatively after 12 months. Improvement in grip strength was slower than range of motion.


Hand ◽  
2021 ◽  
pp. 155894472199973
Author(s):  
Nicholas Munaretto ◽  
Adam Tagliero ◽  
Raahil Patel ◽  
Peter C. Rhee

Background Little information exists to guide decision-making with regard to distal radius fractures in the setting of ipsilateral hemiparesis or hemiplegia. Methods Patients who sustained a distal radius fracture in the setting of ipsilateral hemiparesis or hemiplegia secondary to brain injury were evaluated. Investigated variables included perioperative pain, preinjury House functional classification score, length of immobilization, radiographic outcome measurements, and time to union. Results There were 15 patients with distal radius fractures with a mean age of 65.9 years. The mean clinical and radiographic follow-up was 2.8 and 2.9 years, respectively. Wrists were placed into the nonoperative group (NOG, n = 10) and operative group (OG, n = 5). Pain significantly decreased at final follow-up for both groups. Baseline House functional classification scores averaged 1.3 and 1.6 for the NOG and OG, respectively, and were maintained at final follow-up. Length of immobilization for the NOG was 46 days and OG was 37 days, P = .15. Radiographic outcomes at final follow-up in the NOG and OG, respectively, were a mean radial height of 9.3 versus. 11.6 mm, radial inclination of 18.3° versus 22.3°, 4.2° dorsal tilt versus 5.3° volar tilt, and tear drop angle of 45.6° versus 44.5°. There were no significant differences in these measurements. Time to radiographic union averaged 58 days for the NOG and 67 days for the OG, P = .42. There were no revision surgeries. Conclusions Based on this small case series, patients with distal radius fracture and ipsilateral hemiparesis or hemiplegia may have similar clinical, functional, and radiographic outcomes, regardless of nonoperative or operative treatment.


Hand ◽  
2021 ◽  
pp. 155894472110289
Author(s):  
Anthony L. Logli ◽  
Marco Rizzo

Background: Owing to the many unique disease characteristics of Parkinson disease (PD)—namely resting tremors, muscular rigidity, and poor bone quality—we hypothesized that this patient population would have inferior outcomes with surgical management of acute distal radius fractures (DRFs) compared with the literature available on the general population. Methods: This is a retrospective observational study performed at a single, level 1, academic center from 2001 to 2020 capturing all adult patients with an isolated, acute, and closed DRF that ultimately underwent operative treatment. International Classification of Diseases 10 codes were used to identify 30 patients for manual chart review. Several patient and fracture characteristics were accounted for and complications, reoperations, and failures of surgical intervention were recorded. Results: There was a total of 7/30 failures (23%), 6/30 reoperations (20%), and 12 complications in 9/30 wrists (complication rate, 30%) at a mean latest follow-up of 11 months (1.2-158 months). Of the 7 failures, 5 were due to loss of reduction, and 2 of them were deep infections with mean time to failure of 8.3 weeks (range, 11 days-5.2 months). Conclusions: This study found a high rate of complications, reoperations, and early failure despite a short follow-up period and a small cohort of patients with PD treated surgically for a DRF. We recommend locked plating if suitable for the fracture type and early involvement of a multidisciplinary team to assist with medical optimization of PD to increase chances of a successful outcome.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
J Mulrain ◽  
K Joshi ◽  
F Doyle ◽  
A Abdulkarim

Abstract Introduction Distal radius fractures are common and trends for fixation have changed with increased use of volar locking plates in recent time. A meta-analysis will summarise the best evidence for treatment. Method A systematic review was conducted using PRISMA methodology to identify studies that reported clinical and/or radiological outcomes in patients with AO type C distal radius fractures when treated with external fixation versus ORIF. Results 10 randomised trials were included in this review, reporting on 967 patients. Clinical outcomes are in favour of volar plating at 3 months post-operation, but no difference between the two groups is seen at 6 or 12 months. Analysis of complication rates shows a minute increase in risk-ratio for volar plating versus external fixation. Subgroup analysis showed significantly higher re-operations after plate fixation and significantly higher infection after external fixation. Conclusions Internal fixation of complex distal radius fractures confers an improved clinical outcome at early follow up only and a minimally increased risk of complications. The improved grip strength with volar plating is only superior at early follow up and no long-term superiority is seen with either intervention. The type of surgery in this injury type therefore remains at the surgeon’s consideration on a case-by-case basis.


2014 ◽  
Vol 15 (1) ◽  
Author(s):  
Paul Ruckenstuhl ◽  
Gerwin A Bernhardt ◽  
Patrick Sadoghi ◽  
Mathias Glehr ◽  
Lukas A Holzer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document