Spectrophotometric estimation of ambroxol hydrochloride and cetirizine hydrochloride in tablets

2008 ◽  
Vol 2 (3) ◽  
pp. 159 ◽  
Author(s):  
NeelaManish Bhatia ◽  
SantoshKumar Ganbavale ◽  
HarinathNivrutti More
2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Deepak Sharma ◽  
Mankaran Singh ◽  
Dinesh Kumar ◽  
Gurmeet Singh

Ambroxol Hydrochloride and Cetirizine Hydrochloride are used for the treatment of bronchitis, cough, and allergy. A simple, economical, accurate, and precise method for simultaneous estimation of Ambroxol Hydrochloride and Cetirizine Hydrochloride in tablet dosage form has been developed. Simultaneous equation method based on measurement of absorbance at two wavelengths, that is, 244 nm and 230 nm, λmax of Ambroxol Hydrochloride and Cetirizine Hydrochloride in pH 6.8 phosphate buffer. Both of these drugs obeyed Beer-Lambert’s law in the concentration range of 2–18 µg/mL for Ambroxol Hydrochloride and 2–20 µg/mL for Cetirizine Hydrochloride. The high values of correlation coefficient (R) indicated good linearity of calibration curve for both the drugs. The accuracy and precision of method were determined and the method was validated statistically. Result of percentage recovery study confirms the accuracy of proposed method. As per the ICH guidelines, the method validation parameters checked were linearity, accuracy, precision, and assay of drug formulation. Based on the results obtained, it can be concluded that the proposed simultaneous equation spectrophotometric method for simultaneous estimation of Ambroxol Hydrochloride and Cetirizine Hydrochloride is rapid, economical, accurate, precise, and reproducible. Hence, the proposed method can be employed for quantitative estimation of Ambroxol Hydrochloride and Cetirizine Hydrochloride from their tablet dosage form.


Author(s):  
Hina Shamshad ◽  
Ali Sayqal ◽  
Jahan Zeb ◽  
Agha Zeeshan Mirza

Abstract A simple, accurate and precise RP-HPLC method was developed for the simultaneous determination of chloroquine, pyrimethamine and cetirizine hydrochloride concentrations in bulk drug and human serum. The assay was performed using a mobile phase of methanol: water (70:30) at pH of 2.8 ± 0.05 on the Purospher C-18 column with UV detection at 230 nm and rosuvastatin used as an internal standard. The retention times observed for chloroquine, pyrimethamine and cetirizine hydrochloride were 3.5, 2.5 and 5.5 minutes, respectively. The method was found to be specific for the assayed drugs showing a linear response in the concentration range of 1–100 μg mL−1 with coefficients of determination values of (r = 0.999). The method was developed and validated according to ICH guidelines. The method was used to monitor the serum samples and was found to be sensitive for therapeutic purposes, showing the potential to be a useful tool for routine analysis in laboratories.


2011 ◽  
Vol 59 (09) ◽  
pp. 440-444
Author(s):  
Feng-Guo Xu ◽  
Ying Liu ◽  
Zun-Jian Zhang ◽  
Yuan Tian ◽  
Yun Chen

Sign in / Sign up

Export Citation Format

Share Document