SNA and SNB measurements: A comparative assessment between measurements in conventional 2D cephalogram and 3D cone-beam computed tomography-generated values

2021 ◽  
Vol 9 (3) ◽  
pp. 71
Author(s):  
BikashRanjan Das ◽  
Pradeep Jain ◽  
Nikita Modi ◽  
Priyanka Soni ◽  
Dipayan Datta ◽  
...  
2021 ◽  
pp. 51-61
Author(s):  
A. Yu. Vasil'ev ◽  
V. V. Petrovskaya ◽  
E. A. Nichipor ◽  
V. G. Alpatova ◽  
N. N. Potrakhov ◽  
...  

During the course of this experimental study tomograms of extracted teeth were analyzed before and after filling the root canals with an endodontic material and fragments of broken metal instruments for root canal treatment. During the first stage of the experiment, untreated extracted teeth were scanned using conebeam computed tomography and microfocus cone-beam computed tomography. A comparative assessment of capabilities of the two methods of cone-beam computed tomography based on examination of untreated root canals was carried out. The second part of the study is dedicated to visualization of root canals that contain foreign high-density materials.


2011 ◽  
Vol 53 (4) ◽  
pp. 501-508 ◽  
Author(s):  
Kivanç Kamburoglu ◽  
Sema Murat ◽  
Eray Kolsuz ◽  
Hakan Kurt ◽  
Selcen Yüksel ◽  
...  

2019 ◽  
Vol 1 (1) ◽  
pp. 16-18 ◽  
Author(s):  
Norafida Bahari ◽  
Nik Azuan Nik Ismail ◽  
Jegan Thanabalan ◽  
Ahmad Sobri Muda

In this article, we evaluate the effectiveness of Cone Beam Computed Tomography, through a case study, in assessing the complication of intracranial bleeding during an endovascular treatment of brain arteriovenous malformation when compared to Multislice-Detector Computed Tomography performed immediately after the procedure. The image quality of Cone Beam Computed Tomography has enough diagnostic value in differentiating between haemorrhage, embolic materials and the arteriovenous malformation nidus to facilitate physicians to decide for further management of the patient.


Author(s):  
Norafida Bahari ◽  
NikAzuan Nik Ismail ◽  
Jegan Thanabalan ◽  
Ahmad Sobri Muda

In this article, we evaluate the effectiveness of Cone Beam Computed Tomography, through a case study, in assessing the complication of intracranial bleeding during an endovascular treatment of brain arteriovenous malformation when compared to Multislice-Detector Computed Tomography performed immediately after the procedure. The image quality of Cone Beam Computed Tomography has enough diagnostic value in differentiating between haemorrhage, embolic materials and the arteriovenous malformation nidus to facilitate physicians to decide for further management of the patient.