scholarly journals A Versatile High Performance Liquid Chromatography Method for Simultaneous Determination of Three Curcuminoids in Pharmaceutical Dosage forms

2012 ◽  
Vol 03 (04) ◽  
Author(s):  
Dalapathi B Gugulothu ◽  
Clara B Fernandes
Author(s):  
Liliya Logoyda ◽  
Yuliya Kondratova ◽  
Dmytro Korobko ◽  
Yuriy Soroka

Objective: The objective of this research was to develop more simple, sensitive, accurate, and less expensive analytical methods for the determination of captopril in medicines by Ultra-high-performance liquid chromatography.Materials and Methods: The chromatographic analysis of captopril performed on liquid chromatography Agilent 1290 Infinity II LC System.Results: A simple, rapid, sensitive, and specific method was developed for the determination of captopril by ultra-high-performance liquid chromatography in mono-medicines and pharmaceutical dosage forms in combination with hydrochlorothiazide without previous separation. Satisfactory resolution was achieved using Fused-Core® technology Ascentis Express C18 column (4.6×150 mm) and a mobile phase consisting of methanol and 0.1% solution of trifluoroacetic acid (40/60, v/v) at a flow rate 1.2 mL/minute and the wavelength detection was 220 nm. Ascentis Express columns, based on Fusеd-core pаrticle technоlogy, prоvide more than twice the speed and efficiency of traditiоnal cоlumns at half the backpressure of sub-2-μm columns. The retention time for captopril was 1.345 minute. The validation of this method was based on the ICH and USP guidelines.Conclusion: The results obtained in this research work clearly indicated that the assay was rapid, sensitive and successfully applied to the determination of both drugs in pharmaceutical dosage forms without interference from tablet excipients.


Author(s):  
Mannem Durga Babu ◽  
Kesana Surendrababu

Objective: The objective of the study was to develop and validate a novel, specific, precise, and simple reversed-phase high-performance liquid chromatography method for the estimation of guaifenesin present in methocarbamol API and its pharmaceutical dosage forms. Methods: The baseline separation for methocarbamol and guaifenesin was achieved by utilizing a Inertsil ODS C18 (250 mm × 4.6 mm) 5 μm column particle size and an isocratic elution method. The mobile phase contains a mixture of water and acetonitrile in the ratio of 70:30 v/v, respectively. The flow rate of the mobile phase was 1.0 mL/min with a column temperature of 25°C and detection wavelength at 272 nm. The method was validated for a limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and reproducibility with the help of the exhibit and simulated samples. Results: The LOD for guaifenesin was 0.62 μg/mL. The LOQ for guaifenesin was 1.87 μg/mL. The correlation coefficient obtained for impurity was >0.99. The recovery was obtained for impurity was 106.56% at 50%, 95.20% at 100%, and 100.45% at 150%. In tablet analysis, we can found 0.26% (<0.5%). Conclusion: The developed method was validated as per the ICH guidelines with respect to specificity, precision, linearity, accuracy, LOD and quantification, ruggedness, robustness, and solution stability.


2020 ◽  
Vol 103 (4) ◽  
pp. 1181-1189
Author(s):  
Xiaoyun Duan ◽  
Xiaofeng Liu ◽  
Yue Dong ◽  
Jing Yang ◽  
Jing Zhang ◽  
...  

Abstract Background Sulfonamides have been widely used in the prevention and clinical treatment of bacterial diseases in livestock and poultry. The use of sulfonamides increases the risk of veterinary drug residues in animal derived foods. The traditional reversed phase liquid chromatography methods for sulfonamides residues detection in animal derived foods have the problem of high consumption of organic solvents. Objective The aim of this study was to establish a green high-performance liquid chromatography method for the detection of sulfonamides residues in different animal-origin foods. Method The sample extraction solutions were purified by the Agela Cleanert PEP-2 cartridge and analyzed by the high-performance liquid chromatography method using ethanol as the green alternative solvent. Results The proposed method was validated in terms of linear range (20–1000 μg/kg), limit of detection (3.0–12.3 μg/kg), limit of quantitation (10–43 μg/kg), accuracy (80.7–101.3%), and repeatability and reproducibility (RSD &lt;5.9% and RSD &lt;8.5% respectively). Conclusions The proposed method is an environmentally friendly, sensitive and reliable high-performance liquid chromatography method for simultaneous determination of sulfonamide residues in animal-origin foods. Highlights In this work, we firstly developed a green high-performance liquid chromatography method for simultaneous determination of the residues of nine sulfonamides in milk and beef with ethanol as the green alternative solvent.


Sign in / Sign up

Export Citation Format

Share Document