scholarly journals A New Kinetic Spectrophotometric Method for Determination of Cefadroxil in Pharmaceutical Formulations Using <i>Lawsonia inermis</i> (Henna) as Natural Reagent

2014 ◽  
Vol 04 (02) ◽  
pp. 116-128 ◽  
Author(s):  
Mohammed Hassan ◽  
Fathy A. Abeed ◽  
Bassam Saif
Author(s):  
Mouhammed Khateeb ◽  
Basheer Elias ◽  
Fatema Al Rahal

A simple and sensitive kinetic spectrophotometric method has been developed for the determination of folic acid (FA) in bulk and pharmaceutical Formulations. The method is based on the oxidation of FA by Fe (III) in sulfuric acid medium. Fe (III) subsequently reduces to Fe (II) which is coupled with potassium ferricyanide to form Prussian blue. The reaction is followed spectrophotometrically by measuring the increase in absorbance at λmax 725 nm. The rate data and fixed time methods were adopted for constructing the calibration curves. The linearity range was found to be 1–20 μg mL-1 for each method. The correlation coefficient was 0.9978 and 0.9993, and LOD was found to be 0.91 and 0.09 μg mL-1 for rate data and fixed time methods, respectively. The proposed method has been successfully applied to the determination of FA in formulations with no interference from the excipients. Statical comparison of the results shows that there is no significant difference between the proposed and pharmacopoeial methods


2006 ◽  
Vol 71 (10) ◽  
pp. 1107-1120 ◽  
Author(s):  
Nafisur Rahman ◽  
Zehra Bano ◽  
Hejaz Azmi ◽  
Mohammad Kashif

Asimple kinetic spectrophotometric method has been developed for the determination of lansoprazole in pharmaceutical formulations. The method is based on the oxidation of the drug with alkaline potassium permanganate at room temperature. The reaction was followed spectrophotometrically by measuring the increase in the absorbance owing to the formation of MnO 42? at 610 nm (Method A) and the decrease in the absorbance at 530 nm due to the disapperance of MnO4? (Method B). Calibration procedures were adopted for the assay of the drug. The calibration curves were linear over the concentration ranges of 5-150 and 5-70?g ml-1, with the corresponding calibration Equations: rate = -3.915x10-6 + 5.271x10-5 c and ?A = 1.04x 10-3 + 1.78x10-3 c for methods A, and B, respectively. A statistical comparison of the results of the proposed procedures with those of the reference spectrophotometric method show excellent agreement and indicated no significant difference between the compared methods in terms of accuracy and precision. Interval hypothesis tests were also performed, which indicated that the true bias of all samples was less than ? 2 %. .


2005 ◽  
Vol 6 (3) ◽  
pp. E543-E551 ◽  
Author(s):  
Nafisur Rahman ◽  
Yasmin Ahmad ◽  
Syed Najmul Hejaz Azmi

Sign in / Sign up

Export Citation Format

Share Document