scholarly journals Free-breathing radial volumetric interpolated breath-hold examinationvsbreath-hold cartesian volumetric interpolated breath-hold examination magnetic resonance imaging of the liver at 1.5T

2016 ◽  
Vol 8 (7) ◽  
pp. 707 ◽  
Author(s):  
Sireesha Yedururi ◽  
HyunSeon C Kang ◽  
Wei Wei ◽  
Nicolaus A Wagner-Bartak ◽  
Leonardo P Marcal ◽  
...  
2014 ◽  
Vol 49 (6) ◽  
pp. 382-389 ◽  
Author(s):  
Michael Ingrisch ◽  
Daniel Maxien ◽  
Felix Schwab ◽  
Maximilian F. Reiser ◽  
Konstantin Nikolaou ◽  
...  

2019 ◽  
Vol 46 (11) ◽  
pp. 1445-1449 ◽  
Author(s):  
Xenofon Baraliakos ◽  
Florian Hoffmann ◽  
Xiaohu Deng ◽  
Yan-Yan Wang ◽  
Feng Huang ◽  
...  

Objective.The volumetric interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) technique can visualize erosive cartilage defects in peripheral joints. We evaluated the ability of VIBE to detect erosions in sacroiliac joints (SIJ) of patients with axial spondyloarthritis (axSpA) compared to the established T1-weighted MRI sequence and computed tomography (CT).Methods.MRI (T1-weighted and VIBE) and CT scans of SIJ of 109 patients with axSpA were evaluated by 2 blinded readers based on SIJ quadrants (SQ). Erosions were defined according to Assessment of Spondyloarthritis international Society (ASAS) definitions. Scores were recorded if readers were in agreement.Results.Erosions were less frequently detected by CT (153 SQ) than by T1-weighted MRI (182 SQ; p = 0.008) and VIBE-MRI (199 SQ; p < 0.001 vs CT and p = 0.031 vs T1-weighted MRI). Taking CT as the gold standard, the sensitivity of VIBE-MRI (71.2%) was higher than that for T1-weighted MRI (63.4%), with similar specificity (87.3% vs 88%, respectively). In linear regression analysis, younger age was significantly associated with occurrence of erosions independently in VIBE-MRI (β = 0.384, p < 0.001) and T1-weighted MRI (β = 0.369, p < 0.001) compared to CT.Conclusion.The VIBE-MRI sequence was more sensitive than T1-weighted MRI in identifying erosive damage in the SIJ, especially in younger patients. This might be due to the ability of VIBE-MRI to identify structural changes in the cartilage that have not yet extended to the underlying bone, where CT seems to be superior.


2019 ◽  
Vol 53 (5) ◽  
pp. 1802188 ◽  
Author(s):  
Jonathan H. Rayment ◽  
Marcus J. Couch ◽  
Nancy McDonald ◽  
Nikhil Kanhere ◽  
David Manson ◽  
...  

Pulmonary magnetic resonance imaging using hyperpolarised 129Xe gas (XeMRI) can quantify ventilation inhomogeneity by measuring the percentage of unventilated lung volume (ventilation defect per cent (VDP)). While previous studies have demonstrated its sensitivity for detecting early cystic fibrosis (CF) lung disease, the utility of XeMRI to monitor response to therapy in CF is unknown. The aim of this study was to assess the ability of XeMRI to capture treatment response in paediatric CF patients undergoing inpatient antibiotic treatment for a pulmonary exacerbation.15 CF patients aged 8–18 years underwent XeMRI, spirometry, plethysmography and multiple-breath nitrogen washout at the beginning and end of inpatient treatment of a pulmonary exacerbation. VDP was calculated from XeMRI images obtained during a static breath hold using semi-automated k-means clustering and linear binning approaches.XeMRI was well tolerated. VDP, lung clearance index and the forced expiratory volume in 1 s all improved with treatment; however, response was not uniform in individual patients. Of all outcome measures, VDP showed the largest relative improvement (−42.1%, 95% CI −52.1–−31.9%, p<0.0001).These data support further investigation of XeMRI as a tool to capture treatment response in CF lung disease.


Sign in / Sign up

Export Citation Format

Share Document