scholarly journals Development and Validation of RP-HPLC Method for the Determination of Sorafenib in Pharmaceutical Dosage Form

Author(s):  
P. Ravi Sankar ◽  
Viswanath A. ◽  
Eswarudu M.M. ◽  
Divya B. ◽  
Neelima K. ◽  
...  

A sensitive, rapid, precise, accurate high-performance liquid chromatographic method was developed for the estimation of Sorafenib (SOR) in the tablet dosage form. Chromatographic separation of SOR was carried out utilizing thermo-scientific model C18 column (4.6 mm i.d. X 250 mm; 5µm particle size) (based on 99.99 % ultra-high purity silica) using mobile phase that consisting of acetonitrile: methanol (40:60 v/v) at a flow rate of 1.0 mL/min. The absorption maximum (?max) of SOR in the mobile phase was found to be 265.5 nm. It had a retention time of 3.223 min. The calibration curve was in linear function of the drug in the concentration range of 2-10 µg/mL (r2 = 0.999) for the optimized method. The regression equation for SOR was found to be Y = 68228 x + 8071. The Detection Limit (DL) & Quantitation Limit (QL) results of SOR were found to be 0.526 µg/mL and 1.594 µg/mL respectively. The developed method was validated in pursuance of ICH Q2 (R1) guidelines. The method was linear, precise, accurate with recoveries in the range of 98 - 102 %, and minimum values of % RSD indicate the accuracy of the method. The detailed quantitative results of the study show that this method is precise, accurate, and cost-effective. Thus, the developed RP-HPLC method can be successfully feasible for the routine quality control analysis of SOR in a pharmaceutical dosage form.

Author(s):  
DYADE GK ◽  
SAWANT RL

Objective: A reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of amlodipine besylate (AD) and valsartan (VAL) in pharmaceutical dosage form, and rosuvastatin (RV) and VAL from the bulk mixture. Method: Chromatographic separation was performed on RP-C18 column. The optimized unique mobile phase (acetonitrile:water and pH adjusted to 4.8 with acetic acid) was pumped at a flow rate of 0.8 ml/min in the ratio of 75:25% v/v, and the eluents were monitored at 245 nm. Results: The assay was performed with tablet and percentage of assay was found to 101.39 for AD and 100.05 for VAL, respectively, and with bulk mixture, percentage of assay was found to 99.58 for RV and 100.32 for VAL, respectively. Linearity was obtained in the concentration range of 1–12 μg/ml for AD, 5–50 μg/mL for VAL, and 2–20 μg/ml for RV. The method was statistically validated and RSD was found to be <2%, indicating high degree of accuracy and precision of the proposed RP-HPLC method. Conclusions: The method suggests usefulness of unique mobile phase during the estimation of two or more multicomponent dosage forms. Due to its simplicity, rapidness, high precision, and accuracy, the proposed RP-HPLC method can be applied for simultaneous determination of AD and VAL in pharmaceutical dosage form, and RV and VAL in bulk mixture.


2017 ◽  
Vol 4 (1) ◽  
pp. 5-10 ◽  
Author(s):  
Ramesh Jayaprakash ◽  
Senthil Kumar Natesan

A simple, economic, accurate, sensitive, specific and precise stability indicating reverse phase high performance liquid chromatographic [RP-HPLC] method for the determination of Regorafenib in pure and tablet dosage from was developed and validated. The chromatographic separation was carried out using Phenomenex Luna-C18 column (4.5x250 mm; 5 µm particle size) as a stationary phase and methanol: acetonitrile: water (55:25:20 v/v/v) as a mobile phase. The flow rate of 1 mL/min was used with PDA detection at 275 nm. The retention time of Regorafenib was 2.480 min. RP-HPLC method was developed with linearity range of 40-240 µg/mL of Regorafenib. The correlation coefficient [r2] was found to be 0.9999. The assay results obtained was in good agreement with the corresponding labeled amount by developed method within range of 98.83 ± 0.6937. Accuracy of the method was confirmed by recovery studies and the recoveries were found to be between 99.61 % and 100.22 %, the corresponding %RSD was found to be 0.2029. Precision, LOD, LOQ, specificity, robustness and ruggedness were performed as per ICH Q2(R1) guidelines and were within the acceptance criteria. This method can be conveniently used to detect the possible degradation product in the dosage form of Regorafenib during stability studies (acidic, alkaline, oxidative, thermal and photolytic). The method proved to be effective on the analysis of stressed marketed tablet formulation.


2008 ◽  
Vol 5 (s2) ◽  
pp. 1149-1153 ◽  
Author(s):  
A. Lakshmana Rao ◽  
B. N. V. Ravi Kumar ◽  
G. G. Sankar

A simple, rapid, sensitive and precise High Performance Liquid Chromatographic (HPLC) method has been developed for the estimation of rabeprazole in bulk and tablet dosage form. In this method RP-C18column (150 mm x 4.6 mm I.D, 5 µ m particle size) with mobile phase consisting of methanol and water in the ratio of 65:35 v/v in isocratic mode was used. The detection wavelength is 284 nm and the flow rate is 0.8 mL/min. Tinidazole is used as internal standard. In the range of 0.25-20 µ g/mL, the linearity of rabeprazole shows a correlation coefficient of 0.9999. The drug and internal standard were eluted at 4.41± 0.05 and 2.16± 0.04 min. respectively. The intra- and inter-day variation was found to be less than 1% showing high precision of the assay method. The detection limit was found to be 100 ng/mL. The mobile phase selected for the proposed method is simple, fast, accurate and precise and hence can be applied for routine quality control analysis of rabeprazole in bluk and its tablet dosage from.


Author(s):  
K. Bhavyasri ◽  
C. H. Mounika ◽  
Narmada Vallakeerthi ◽  
M. Sumakanth

Aims: To develop and validate a new, simple, rapid, precise and accurate Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method for the quantitative determination of Tigecycline in bulk and pharmaceutical dosage form. Study Design: Place and Duration of the Study: RBVRR women's college of pharmacy, Barkatpura, Hyderabad, between june 2019 and july 2020. Methodology: The RP-HPLC method was developed on Sunsil C18 150 mm x 4.6mm x 5µ column using acetonitrile : water (pH maintained at 3.5 with acetic acid) [70:30] as mobile phase at flow rate 0.8 ml/min and UV detection at 250 nm. Results: Tigecycline exhibited linearity over the concentration range of 5-40 µg/mL (R2 > 0.999). The analytical method showed good precision with % RSD below 2. The method showed suitable accuracy and robustness. Conclusion: Validation of the developed method was done as per International Conference on Harmonization (ICH) Q2R1 guidelines.


Author(s):  
Amruta A. Chaudhary ◽  
Ashwini V. Shelke ◽  
Anil G. Jadhav

A specific, accurate rp-HPLC (reversed-phase high performance liquid chromatographic) method was developed for the quantification of Cabozantinib. The effective separation was achieved through reversed-phased C18 column 4.6 x 250 mm, 5µm using a mobile phase Methanol: phosphate buffer (ph. 3.00) with orthophosphoric acid (OPA) (55:45 % v/v). The flow rate of the mobile phase was found to be 0.8 mL/min. The detection was carried at a wavelength of 244 nm. The retention time of Cabozantinib was found to be 3.702 min. The correlation coefficient was found to be 0.9999. The developed method was accurately validated in the terms of accuracy, linearity range, precision, system suitability, robustness, limit of detection and limit of quantification. The details presented in this test will be useful for industrial application for determining Cabozantinib in active pharmaceutical ingredient and pharmaceutical dosage form.


Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


Author(s):  
Sireesha D ◽  
Sai Lakshmi E ◽  
Sravya E ◽  
Vasudha Bakshi

A new simple, rapid, specific, accurate, precise and novel Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the estimation of Sitagliptin Phosphate in the pharmaceutical dosage form. The chromatographic separation for Sitagliptin was achieved with mobile phase containing methanol, Thermoscientific C18 column, (250x4.6 particle size of 5μ) at room temperature and UV detection at 248 nm. The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Sitagliptin was 1.91min. The above method was validated in terms of linearity, accuracy, precision, LOD and LOQ in accordance with ICH guidelines.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


Author(s):  
Sushil D. Patil ◽  
Pravin B. Shelke ◽  
Priti Aher ◽  
Maswood Ahmed Hafizur Rahman

A simple, rapid, economic, sensitive and precise HPLC method has been developed for the simultaneous determination of Sulphadoxine and Pyrimethamine in pharmaceutical dosage form by taking Tolterodine as an internal standard. The method was carried out using Phenomenex C18 (4.6ID × 250mm; 5µm) column and mobile phase comprised of methanol and Phosphate Buffer in proportion of ratio 60:40 v/v. The flow rate was 1.0mL/min and detection was carried out at 276nm. The retention time of Sulphadoxine, Pyrimethamine and Tolterodine were found to be 2.967, 4.058 and 6.908 respectively. Linearity of Sulphadoxine and Pyrimethamine in the range of 2 to 12μg/mL and 4 to 24μg/mL respectively. The % recoveries of Sulphadoxine and Pyrimethamine were found to be in between 99.93% to 99. 96 % respectively. The proposed method is suitable for the routine quality control analysis for simultaneous determination of Sulphadoxine and Pyrimethamine was in bulk and pharmaceutical dosage form.


Sign in / Sign up

Export Citation Format

Share Document