Clinical Effect Analysis of Locking Compression Plate in Treatment of Limb Fracture

2021 ◽  
2020 ◽  
Vol 9 (1) ◽  
Author(s):  
HanPing Huang

To analyze the effect of locking compression plate on the success rate of operation and the time of postoperative recovery.Methods :120 patients with limb fractures from March 2018 to March 2020 were randomly divided into control group (60 cases) and observation group (60 cases). The control group was treated with plate screw internal fixation, The observation group used locking compression plate internal fixation, Compare the effect of treatment, the success rate of operation and the time of postoperative recovery.results: compared the effective rate of the two groups, the observation group (93.33%) was significantly higher than the control group (75.00%). compared with the two groups, the success rate of operation and the time of postoperative recovery, the observed composition power was higher than that of the control group, and the postoperative recovery time was lower than that of the control group, P <0.05.Conclusion: The use of locking compression plate for the treatment of limb fracture can significantly increase the probability of successful operation, shorten the recovery time after operation, the overall curative effect is ideal, and the clinical popularization value is high.


2011 ◽  
Vol 15 (2) ◽  
pp. 57-61
Author(s):  
Wong Hing-Cheong ◽  
Wong Hin-Keung ◽  
Wong Kam-Yiu

Objective The aim of this retrospective study was to analyse the clinical outcome of the application of stainless steel 2.0-mm locking compression plate (LCP) system for the treatment of comminuted hand fractures in Asian adults. Methods Six patients who had comminuted hand fractures were treated by open reduction and internal fixation with the application of stainless steel 2.0-mm LCP (AO Compact Hand System; Synthes, Oberdorf, Switzerland) from December 2009 to October 2010. The total arc of motion of fingers, grip power, complications, and additional surgery were recorded. Results Three out of six patients eventually restored good hand functions in terms of the total arc of finger motion (>220°) and grip power. The commonest complication was skin impingement in finger region by the implant (4 cases). Another common complication was restricted range of motion (3 cases). One patient had minimal degree of malrotation of his left little finger. Additional surgery was required in all the patients for implant removal (6 cases), tenolysis (3 cases), and capsulotomy (2 cases). Conclusions The stainless steel 2.0-mm LCP is useful for the fixation of unstable comminuted hand fractures, especially in metacarpal bones, because of its advantage of better stability, which allows more aggressive rehabilitation. However, its design is not very versatile and, therefore, limits its use in the finger region. Its bulkiness frequently causes implant impingement. The patients must be informed about the chance of implant removal later.


2015 ◽  
Vol 39 (11) ◽  
pp. 2227-2237 ◽  
Author(s):  
Yu Zhou ◽  
Yanbiao Wang ◽  
Lifeng Liu ◽  
Zhenyu Zhou ◽  
Xuecheng Cao

2018 ◽  
Vol 31 (05) ◽  
pp. 356-363 ◽  
Author(s):  
Anton Fürst ◽  
Elisabeth Ranninger ◽  
José Suárez Sánchez-Andrade ◽  
Jan Kümmerle ◽  
Christoph Kühnle

Objectives It was recently shown that biomechanical stability achieved with a locking compression plate (LCP) for ventral cervical fusion in horses is similar to the commonly used Kerf cut cylinder. The advantages of the LCP system render it an interesting implant for this indication. The goal of this report was to describe surgical technique, complications and outcome of horses that underwent ventral fusion of two or three cervical vertebrae with an LCP. Methods Medical records of eight horses were reviewed for patient data, history, preoperative grade of ataxia, diagnostic imaging, surgical technique and complications. Follow-up information was obtained including clinical re-examination and radiographs whenever possible. Results Two (n = 5) or 3 (n = 3) cervical vertebrae were fused in a mixed population with a median age of 9 months, median weight of 330 kg and median grade of ataxia of 3/5. A narrow 4.5/5.0 LCP (n = 6), a broad 4.5/5.0 LCP (n = 1) and a human femur 4.5/5.0 LCP (n = 1) were applied. Two horses were re-operated due to implant loosening. Six patients developed a seroma. Long-term complications included ventral screw migration in four, spinal cord injury in one and plate breakage in two horses at 720 to 1116 days after surgery. Outcome was excellent in three, good in four, poor in one patient. Clinical Significance The use of an LCP for ventral cervical vertebral fusion is associated with good clinical results. However, a careful surgical technique is required to further reduce the complication rate.


2014 ◽  
Vol 22 (3) ◽  
pp. 287-293 ◽  
Author(s):  
Wei Ting Lee ◽  
Diarmuid Murphy ◽  
Fareed HY Kagda ◽  
Joseph Thambiah

2016 ◽  
Vol 41 (6) ◽  
pp. e151-e156 ◽  
Author(s):  
Jorge G. Boretto ◽  
Gerardo L. Gallucci ◽  
Pablo De Carli

Sign in / Sign up

Export Citation Format

Share Document