scholarly journals Influence of Time on Bond Strength After Bleaching with 35% Hydrogen Peroxide

2008 ◽  
Vol 9 (2) ◽  
pp. 81-88 ◽  
Author(s):  
Flávia Martão Flório ◽  
Cinthia Maria Barbosa ◽  
Robson Tetsuo Sasaki ◽  
Robera Tarkany Basting

Abstract Aim The aim of this in vitro study was to evaluate the influence of time after treatment with a 35% hydrogen peroxide bleaching agent on the shear bond strength between composite resin and sound enamel and dentin. Methods and Materials Eighty dental slabs - 40 enamel (E) slabs and 40 dentin (D) slabs - were embedded, flatted, and divided into four groups (n=10). In G1 the E and D slabs were kept in artificial saliva for 14 days. For the G2, G3, and G4 groups the E and D slabs were submitted to bleaching treatment with a 35% hydrogen peroxide bleaching agent. At different times after bleaching treatments (G2=immediate; G3=seven days; G4= fourteen days), composite resin cylinders were made using an adhesive system. Tests were performed in a universal testing machine at a speed of 0.5 mm/min to obtain the values in MPa. Results For enamel, the Kruskal-Wallis test and Dunn Method showed G1 differed significantly from G2 (G1=13.40 a; G2=6.64 b; G3=16.76 a; G4=11.64 ab). For dentin, the analysis of variance (ANOVA) and Tukey tests showed that G1 differed significantly from G2 and G3 (G1=12.11 a; G2=4.97 b; G3=8.67 c; G4=11.86 ac). Conclusion It is recommended adhesive restorative procedures in enamel be delayed for seven days postbleaching treatment with 35% hydrogen peroxide, while restorations in dentin should be delayed for 14 days following bleaching treatment. Citation Barbosa CM, Sasaki RT, Flório FM, Basting RT. Influence of Time on Bond Strength After Bleaching with 35% Hydrogen Peroxide. J Contemp Dent Pract 2008 February;(9)2:081-088.

2004 ◽  
Vol 18 (1) ◽  
pp. 75-79 ◽  
Author(s):  
Erica Cappelletto Nogueira Teixeira ◽  
Cecilia Pedroso Turssi ◽  
Anderson Takeo Hara ◽  
Mônica Campos Serra

It has been reported that bond strength of resin to tooth structure can be reduced when the bonding procedure is carried out immediately after the bleaching treatment. This study evaluated the effect of bleaching of non-vital teeth bleaching on the shear bond strength (SBS) of composite resin/bovine dentin interface and the influence of delaying the bonding procedures for different time intervals following internal bleaching. According to a randomized block design, composite resin cylinders (Z100/Single bond - 3M) were bonded to the flattened dentin surface of two hundred and fifty-six teeth which had previously been subjected to four different treatments: SPH - sodium perborate + 30% hydrogen peroxide; SPW - sodium perborate + distilled water; CP - 37% carbamide peroxide; and CON - distilled water (control), each one followed by storage in artificial saliva for 0 (baseline), 7, 14, and 21 days after bleaching (n = 16). The bleaching agents in the pulp chambers were replaced every 7 days, over 4 weeks. The SBS test of the blocks was done using a universal testing machine. The ANOVA showed that there was no significant interaction between time and bleaching agents, and that the factor time was not statistically significant (p > 0.05). For the factor bleaching treatment, the Student's t-test showed that [CON = CP] > [SPW = SPH]. The bleaching of non-vital teeth affected the resin/dentin SBS values when sodium perborate mixed with 30% hydrogen peroxide or water was used, independently of the elapsed time following the bleaching treatment.


2005 ◽  
Vol 16 (2) ◽  
pp. 107-111 ◽  
Author(s):  
Eduardo Batista Franco ◽  
Lawrence Gonzaga Lopes ◽  
Paulo Henrique Perlatti D'Alpino ◽  
José Carlos Pereira

The purpose of this study was to investigate the effect of pH of different adhesive systems on the polymerization of a chemically cured composite resin (Adaptic - AD), by means of tensile bond strength testing. The adhesive systems tested were: ARM, Prime & Bond 2.1 (PB), Scotchbond Multi Purpose (SMP) and Single Bond (SB). Bond strength at the resin/adhesive system/resin interface was assessed. Five groups (n=5) were formed, according to following configuration: G1: AD/ARM/AD; G2: AD/PB/AD; G3: AD/SMP/AD; G4: AD/SB/AD; G5: AD/AD (no adhesive). A two-mold stainless steel matrix with a cone-shaped opening (1-mm-thick; 4 mm in diameter) was used to obtain resin discs. AD resin was inserted into the first mold, left-self curing and an adhesive layer was applied onto resin surface and light-cured. The second mold was assembled over the first and was filled with the resin. After 10 min, this setting was loaded in tension in a universal testing machine running at a crosshead speed of 0.5 mm/min. Data were submitted to one-way ANOVA and Tukey's test (p<0.05). Bond strength means (kgf) were: G1: 15.23 ± 4.1; G2: 0.00 ± 0.0; G3: 16.96 ± 2.4; G4: 10.08 ± 2.7; G5: 15.44 ± 0.9. There were statistically significant differences (p<0.05) between G2-G1; G2-G3; G2-G4; G4-G1; G4-G3. The systems with the lowest pHs (PB and SB) yielded the lowest bond strength. The findings of this in vitro study demostrates that the pH of adhesive systems influences the polymerization and bond strength of chemically cured resin materials. The low pH simplified adhesive systems showed distinct degrees of incompatibility with the chemically cured resin, when compared to the conventional adhesive systems.


2015 ◽  
Vol 16 (4) ◽  
pp. 259-263
Author(s):  
Mateus Rodrigues Tonetto ◽  
Rudys Rodolfo de Jesus Tavarez ◽  
Leily Macedo Firoozmand ◽  
Matheus Coelho Bandeca ◽  
Shilpa H Bhandi ◽  
...  

ABSTRACT Aim The aim of this study was to investigate in vitro the bond strength of composite resins on enamel previously treated with whitening strips. Materials and methods A total of 48 bovine incisors were allocated to four experimental groups (n = 12 each): G1 (WSC)— treated with 9.5% hydrogen peroxide whitening strips (3D White Whitestrips® Advanced Vivid/CREST); G2 (WSO)—treated with 10% hydrogen peroxide whitening strips (3D WhiteTM/Oral B); G3 (WG)—treated with 7.5% hydrogen peroxide gel with fluorine, calcium and potassium nitrate (White Class®/FGM); and G4 (C)—control not subjected to bleaching treatment. The specimens were subjected to bleaching over 2 weeks following the manufacturers’ instructions. Following the elaboration of the composite resin test specimens, the samples were stored in artificial saliva and subsequently subjected to the microshear test using the universal testing machine (EMIC®). The bond strength values were analyzed by one-way ANOVA and Tukey's statistical test (5%). Results Significant differences were observed among the investigated groups (p < 0.05). The G3-WG exhibited greater values compared with the control group and the groups treated with strips, G1-WSC and G2-WSO. Analysis of the bond interface revealed that a large fraction of the failures occurred at the enamel-resin interface. Conclusion The bond strength decreased following 14 days of treatment with bleaching strips, whereas the whitening gel with 7.5% hydrogen peroxide, calcium and fluorine increased the bond strength. How to cite this article Firoozmand LM, dos Reis WLM, Vieira MA, Nunes AG, de Jesus Tavarez RR, Tonetto MR, Bramante FS, Bhandi SH, de Oliveira Roma RV, Bandeca MC. Can Whitening Strips interfere with the Bond Strength of Composite Resins? J Contemp Dent Pract 2015;16(4):259-263.


2004 ◽  
Vol 18 (2) ◽  
pp. 162-167 ◽  
Author(s):  
Roberta Tarkany Basting ◽  
Patrícia Moreira de Freitas ◽  
Luiz André Freire Pimenta ◽  
Mônica Campos Serra

This in vitro study evaluated the shear bond strength (SBS) of dentin treated with two 10% carbamide peroxide bleaching agents 15 days after bleaching and storage in artificial saliva. Dentin fragments were randomly divided into 3 groups (n = 20) for the treatment with the two different bleaching agents (Rembrandt 10% or Opalescence 10%) or with a placebo agent, applied to the tooth surface for 8 hours a day. During the remaining time, the specimens were stored in artificial saliva. After 42 days, the fragments were stored in artificial saliva for 14 days. Another group (n = 20) was exposed to distilled and deionized water for 56 days. An adhesive system and microhybrid composite resin were used to prepare specimens for the SBS test. SBS tests were performed and the fractured surfaces were visually examined using a stereoscope at 30 X magnification. The analysis of variance (ANOVA) and SIDAK tests showed higher SBS values for dentin treated with Opalescence 10% than for dentin treated with Rembrandt 10% or placebo. Groups treated with Rembrandt 10%, Opalescence 10% or placebo did not differ from the group treated with distilled and deionized water. Ten percent carbamide peroxide agents or a placebo agent caused no differences in SBS of dentin after 15 days of storage in artificial saliva.


2011 ◽  
Vol 22 (4) ◽  
pp. 317-321 ◽  
Author(s):  
Aline Evangelista Souza-Gabriel ◽  
Lilian Oliveira Cambaúva Vitussi ◽  
Camila Milani ◽  
Edson Alfredo ◽  
Danielle Cristine Furtado Messias ◽  
...  

This study assessed the effect of bleaching protocols with 38% hydrogen peroxide (HP) and post-bleaching times on shear bond strength of a composite resin to dentin. One-hundred slabs of intracoronary dentin were included and randomly assigned into 2 groups according to the bleaching protocol: HP (2 applications of 10 min each) and HP activated by LED laser (2 applications of 10 min each/45 s of light activation). Groups were subdivided according to the post-bleaching time (n=10): 1 day, 3 days, 7 days, 10 days and 14 days. The control group was unbleached and restored (n=10). The specimens were restored with Single Bond adhesive system/Filtek Z250 resin using a polytetrafluorethylene matrix and were submitted to the shear bond strength testa after 24 h,. Data were analyzed by ANOVA and Tukey's test (α=0.05). Unbleached group (0.283 ± 0.134) had the highest bond strength and was statistically similar (p>0.05) to HP/10 days (0.278 ± 0.064), HP + LED laser/10 days (0.280 ± 0.078), HP/14 days (0.281 ± 0.104), HP + LED laser/14 days (0.277 ± 0.093). Lower bond strength were verified in HP/1 day (0.082 ± 0.012), HP/3 days (0.079 ± 0.013), HP + LED laser/1 day (0.073 ± 0.018) and HP + LED laser/3 days (0.080 ± 0.015), which were statistically similar (p>0.05). HP/7 days (0.184 ± 0.154) and HP + LED laser/7 days (0.169 ± 0.102) had intermediate values (p<0.05). The restorative procedure of intracoronary dentin bleached with 38% HP with or without the use of light source should be performed after at least 10 days after the bleaching treatment.


2012 ◽  
Vol 37 (5) ◽  
pp. 526-531 ◽  
Author(s):  
CRG Torres ◽  
CF Ribeiro ◽  
E Bresciani ◽  
AB Borges

SUMMARY The aim of the present study was to evaluate the effect of 20% and 35% hydrogen peroxide bleaching gels on the color, opacity, and fluorescence of composite resins. Seven composite resin brands were tested and 30 specimens, 3-mm in diameter and 2-mm thick, of each material were fabricated, for a total of 210 specimens. The specimens of each tested material were divided into three subgroups (n=10) according to the bleaching therapy tested: 20% hydrogen peroxide gel, 35% hydroxide peroxide gel, and the control group. The baseline color, opacity, and fluorescence were assessed by spectrophotometry. Four 30-minute bleaching gel applications, two hours in total, were performed. The control group did not receive bleaching treatment and was stored in deionized water. Final assessments were performed, and data were analyzed by two-way analysis of variance and Tukey tests (p&lt;0.05). Color changes were significant for different tested bleaching therapies (p&lt;0.0001), with the greatest color change observed for 35% hydrogen peroxide gel. No difference in opacity was detected for all analyzed parameters. Fluorescence changes were influenced by composite resin brand (p&lt;0.0001) and bleaching therapy (p=0.0016) used. No significant differences in fluorescence between different bleaching gel concentrations were detected by Tukey test. The greatest fluorescence alteration was detected on the brand Z350. It was concluded that 35% hydrogen peroxide bleaching gel generated the greatest color change among all evaluated materials. No statistical opacity changes were detected for all tested variables, and significant fluorescence changes were dependent on the material and bleaching therapy, regardless of the gel concentration.


2003 ◽  
Vol 27 (1) ◽  
pp. 35-39 ◽  
Author(s):  
Silvia Pithan ◽  
Ricardo de Sousa Vieira ◽  
Marcelo Carvalho Chain

The aim of this study was to measure in vitro; the tensile bond strength of three intracanal posts used in anterior primary teeth. A total of 45 single rooted primary anterior teeth were selected for the study and the crowns sectioned leaving 1mm above the cement-enamel junction. The roots were then assigned to three groups according the type of retention used. All roots were endodonticaly treated, a 4-mm of the canal was cleansed and a base of glass ionomer cement was put at the bottom of the prepared canal. The roots were then prepared to receive intracanal posts using a # 4137 diamond bur (KG Sorensen) used in a depth of 3-mm of the length of the canal. All the prepared roots were acid etched with a 37% phosphoric acid gel for 15 seconds, rinsed, dried and the dentin adhesive Single Bond (3M) was applied. Group I received intracanal posts and cores made of composite resin (Filtek Z 250, 3M). Group II intracanal posts were made from a 0.6mm orthodontic wire bent as a Greek letter type (gamma), fixed with the Z 250 composite resin and cores were built with the same composite. Finally Group III received intracanal retention made of a fiber glass post (Fibrekor Post, Generic/Pentron) with 1.25mm diameter, fixed with Z 250 and cores were made like the other groups. The samples were submitted to tension in a universal- testing machine (Instron, model 4444). Statistical analysis (ANOVA) reveled that there were no statistically significant differences between the groups. On the basis of the results of this in vitro study it was concluded that the type of intracanal post did not interfere with the tensile strength and the most frequent type of failure was of adhesive type, corresponding to 74% of the sample.


2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Alessandra B. Borges ◽  
Carlos R. G. Torres ◽  
Paulo A. B. de Souza ◽  
Taciana M. F. Caneppele ◽  
Luciana F. T. F. Santos ◽  
...  

Thisin vitrostudy evaluated the effect of 35% hydrogen peroxide (HP) bleaching gel modified or not by the addition of calcium and fluoride on enamel susceptibility to erosion. Bovine enamel samples (3 mm in diameter) were divided into four groups (n=15) according to the bleaching agent: control—without bleaching (C); 35% hydrogen peroxide (HP); 35% HP with the addition of 2% calcium gluconate (HP + Ca); 35% HP with the addition of 0.6% sodium fluoride (HP + F). The bleaching gels were applied on the enamel surface for 40 min, and the specimens were subjected to erosive challenge with Sprite Zero and remineralization with artificial saliva for 5 days. Enamel wear was assessed using profilometry. The data were analyzed by ANOVA/ Tukey’s test (P<0.05). There were significant differences among the groups (P=0.009). The most enamel wear was seen for C (3.37±0.80 μm), followed by HP (2.89±0.98 μm) and HP + F (2.72±0.64 μm). HP + Ca (2.31±0.92 μm) was the only group able to significantly reduce enamel erosion compared to C. The application of HP bleaching agent did not increase the enamel susceptibility to erosion. However, the addition of calcium gluconate to the HP gel resulted in reduced susceptibility of the enamel to erosion.


2014 ◽  
Vol 13 (1) ◽  
pp. 7
Author(s):  
Dewi Puspitasari ◽  
Andi Soufyan ◽  
Ellyza Herda

Composite resin is a widely used aesthetic restoration. The restoration can fail due to secondary caries. Chlorhexidinegluconate 2% is used as a cavity disinfectant to eliminate microorganisms on the prepared cavity and to prevent thesecondary caries. The purpose of this study was to analyze the effect of chlorhexidine gluconate 2% to the bondstrength of composite resin with self etch system adhesive on dentine. Sixteen specimens of buccal dentine of premolarscrown are divided into 2 different groups. Group I: Clearfil SE Bond self-etch primer was applied for 20 seconds,Clearfil SE Bond bonding was applied for 5 seconds and polymerized for 10 seconds. Composite resin was constructedincrementally and polymerized for 20 seconds. Group II: prior to self etch primer application as in group I,chlorhexidine gluconate 2% was applied for 15 seconds. Shear bond strength was tested using Testing machine andanalyzed with unpaired T test. The highest shear bond strength was obtained by applying chlorhexidine gluconate 2%.The study concludes that chlorhexidine gluconate 2% application to dentine did not affect significantly to the bondstrength composite resin using self etch adhesive systems.


2021 ◽  
Vol 23 (4) ◽  
pp. 277-281
Author(s):  
Rodrigo Galo ◽  
Isabela Maluta ◽  
Marta Maria Martins Giamatei Contente ◽  
Carolina Paes Torres ◽  
Maria Cristina Borsatto

AbstractIn the routine clinical situation, the contamination by blood and/or saliva in restorative procedures can be happen in non-cooperation of the patient in dental office. The aim of the study was to assess in vitro shear bond strength of a resin sealant associated with two types of adhesives contaminated with saliva and blood. Healthy human molars were used and the specimens and the crowns were sectioned in the bucco-lingual direction, thus obtaining two segments of similar proportions (mesial and distal), totaling 60 surfaces, and the surfaces were randomly divided into 4 groups (n = 15). Group I (control) received no type of contamination and the sealant was applied. In group II, the surfaces were contaminated with 10 μl of saliva/blood and the sealant was applied. In group III, the surfaces were contaminated with 10 μl of saliva/blood and the Single Bond total-etch adhesive system was applied followed by application of sealant. In group IV, the surfaces were contaminated with 10 μl of saliva/blood and the Prime & Bond NT total-etch adhesive system was applied followed by the application of sealant. Samples were tested in the universal testing machine and the analysis of shear bond strength was performed. A difference between Group I (12.61MPa) and the other groups was found; Group II (2. 28MPa) was different than Groups III (7.07MPa) and IV (7.79MPa), but Groups III and IV were similar. The application of an adhesive system when there is contamination with saliva/blood is required prior to application of pit and fissure sealants. Keywords: Pit and Fissure Sealants. Biological Contamination. Shear Strength. ResumoNa situação clínica de rotina, a contaminação por sangue e/ou saliva em procedimentos restauradores pode ocorrer em pacientes que não colaboram no consultório odontológico. O objetivo do estudo foi avaliar a resistência ao cisalhamento in vitro de um selante de resina associado a dois tipos de adesivos contaminados com saliva e sangue. Foram utilizados molares humanos saudáveis e os espécimes e as coroas foram seccionados na direção bucal-lingual, obtendo assim dois segmentos de proporções semelhantes (mesial e distal), totalizando 60 superfícies, e as superfícies foram divididas aleatoriamente em 4 grupos (n = 15). O Grupo I (controle) não recebeu nenhum tipo de contaminação e o selante foi aplicado. No grupo II, as superfícies foram contaminadas com 10 μl de saliva / sangue e o selante foi aplicado. No grupo III, as superfícies foram contaminadas com 10 μl de saliva / sangue e o sistema adesivo Single-Bond foi aplicado seguindo a aplicação de selante. No grupo IV, as superfícies foram contaminadas com 10 μl de saliva / sangue e o sistema adesivo de ataque total Prime & Bond NT foi aplicado seguido da aplicação de vedante. As amostras foram testadas na máquina de ensaio universal e a análise da resistência à ligação ao cisalhamento foi realizada. Uma diferença entre o Grupo I (12,61MPa) e os outros grupos foi encontrada; O Grupo II (2,28 MPa) foi diferente dos Grupos III (7,07MPa) e IV (7,79 MPa), mas os Grupos III e IV foram semelhantes. A aplicação de um sistema adesivo quando existe contaminação com saliva / sangue é necessária antes da aplicação de selantes de fissura e fissura.. Palavras-chave: Selantes de Fossas e Fissuras. Contaminação Biológica. Resistência ao Cisalhamento.


Sign in / Sign up

Export Citation Format

Share Document