scholarly journals Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

2013 ◽  
Vol 43 (2) ◽  
pp. 51 ◽  
Author(s):  
Judy Chia-Chun Yuan ◽  
Cortino Sukotjo
2020 ◽  
Vol 29 (5) ◽  
pp. 429-435 ◽  
Author(s):  
Alexandra Tsigarida ◽  
Konstantinos Chochlidakis ◽  
David Fraser ◽  
Evangelia Lampraki ◽  
Erna R. Einarsdottir ◽  
...  

2020 ◽  
Vol 29 (6) ◽  
pp. 479-488 ◽  
Author(s):  
Konstantinos Chochlidakis ◽  
David Fraser ◽  
Evangelia Lampraki ◽  
Erna R. Einarsdottir ◽  
Abdul Basir Barmak ◽  
...  

2011 ◽  
Vol 23 (5) ◽  
pp. 577-583 ◽  
Author(s):  
Julien Luraschi ◽  
Martin Schimmel ◽  
Jean-Pierre Bernard ◽  
German O. Gallucci ◽  
Urs Belser ◽  
...  

2021 ◽  
Vol 11 (9) ◽  
pp. 3770
Author(s):  
Monica Tatarciuc ◽  
George Alexandru Maftei ◽  
Anca Vitalariu ◽  
Ionut Luchian ◽  
Ioana Martu ◽  
...  

Inlay-retained dental bridges can be a viable minimally invasive alternative when patients reject the idea of implant therapy or conventional retained full-coverage fixed dental prostheses, which require more tooth preparation. Inlay-retained dental bridges are indicated in patients with good oral hygiene, low susceptibility to caries, and a minimum coronal tooth height of 5 mm. The present study aims to evaluate, through the finite element method (FEM), the stability of these types of dental bridges and the stresses on the supporting teeth, under the action of masticatory forces. The analysis revealed the distribution of the load on the bridge elements and on the retainers, highlighting the areas of maximum pressure. The results of our study demonstrate that the stress determined by the loading force cannot cause damage to the prosthetic device or to abutment teeth. Thus, it can be considered an optimal economical solution for treating class III Kennedy edentation in young patients or as a provisional pre-implant rehabilitation option. However, special attention must be paid to its design, especially in the connection area between the bridge elements, because the connectors and the retainers represent the weakest parts.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1401
Author(s):  
Doo-Bin Song ◽  
Man-So Han ◽  
Si-Chul Kim ◽  
Junyong Ahn ◽  
Yong-Woon Im ◽  
...  

This study investigated the fitting accuracy of titanium alloy fixed dental prostheses (FDP) after sequential CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) fabrication. A three-unit FDP model connecting mandibular second premolars and molars was prepared and scanned to fabricate titanium FDPs by CAD/CAM milling. A total of six FDPs were sequentially milled in one titanium alloy disk using a new set of burs every time (n = 4). The fitting accuracy of FDPs was mesiodistally evaluated by a silicone replica technique and the measurement was triplicated at four different locations: MO (marginal opening), MG (marginal gap), AG (axial gap), and OG (occlusal gap). Data were statistically analyzed using ANOVA and Tukey’s HSD test. The fitting accuracy of PMMA (polymethyl methacrylate) FDPs milled using the worn or new bur were evaluated by the same procedure (n = 6). The mean dimensions of titanium FDP for all measuring positions, except for AG, were significantly increased from the third milling. However, no difference was noted between the first FDP and the second FDP milled with the same set of burs. Severe edge chippings were observed in all milling burs. Detrimental effects of the worn burs on the fitting accuracy were demonstrated in the CAD/CAM-milled PMMA FDP. The results recommend proper changing frequency of cutting burs to achieve the quality of fit and predictable outcomes for dental CAD/CAM prostheses.


Sign in / Sign up

Export Citation Format

Share Document