Optical Technology for Detecting Disease Related to Blood Flow Condition

2020 ◽  
Vol 23 (5) ◽  
pp. 353-358
Author(s):  
Tomoaki Kyoden ◽  
Shunsuke Akiguchi ◽  
Tomoki Tajiri ◽  
Tsugunobu Andoh ◽  
Tadashi Hachiga
Biorheology ◽  
2011 ◽  
Vol 48 (3-4) ◽  
pp. 219-228 ◽  
Author(s):  
Chao-Tsung Chen ◽  
Shih-Min Huang ◽  
Hsin Hsiu ◽  
Wei-Chen Hsu ◽  
Feng-Cheng Lin ◽  
...  

PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0241727
Author(s):  
Hafizur Rahman ◽  
Iraklis I. Pipinos ◽  
Jason M. Johanning ◽  
Sara A. Myers

Background Patients with peripheral artery disease with intermittent claudication (PAD-IC) have altered gait variability from the first step they take, well before the onset of claudication pain. The mechanisms underlying these gait alterations are poorly understood. Aims To determine the effect of reduced blood flow on gait variability by comparing healthy older controls and patients with PAD-IC. We also determined the diagnostic value of gait variability parameters to identify the presence of PAD. Methods A cross-sectional cohort design was used. Thirty healthy older controls and thirty patients with PAD-IC walked on a treadmill at their self-selected speed in pain free walking (normal walking for healthy older controls; prior to claudication onset for PAD) and reduced blood flow (post vascular occlusion with thigh tourniquet for healthy older controls; pain for PAD) conditions. Gait variability was assessed using the largest Lyapunov exponent, approximate entropy, standard deviation, and coefficient of variation of ankle, knee, and hip joints range of motion. Receiver operating characteristics curve analyses of the pain free walking condition were performed to determine the optimal cut-off values for separating individuals with PAD-IC from those without PAD-IC. Results and discussion Patients with PAD-IC have increased amount of variability for knee and hip ranges of motion compared with the healthy older control group. Regarding the main effect of condition, reduced blood flow demonstrated increased amount of variability compared with pain free walking. Significant interactions between group and condition at the ankle show increased values for temporal structure of variability, but a similar amount of variability in the reduced blood flow condition. This demonstrates subtle interactions in the movement patterns remain distinct between PAD-IC versus healthy older controls during the reduced blood flow condition. A combination of gait variability parameters correctly identifies PAD-IC disease 70% of the time or more. Conclusions Gait variability is affected both by PAD and by the mechanical induction of reduced blood flow. Gait variability parameters have potential diagnostic ability, as some measures had 90.0% probability of correctly identifying patients with PAD-IC.


Author(s):  
Zengsheng Chen ◽  
Sofen K. Jena ◽  
Guruprasad A. Giridharan ◽  
Steven C. Koenig ◽  
Mark S. Slaughter ◽  
...  

2007 ◽  
Vol 6 (2) ◽  
pp. 135-137
Author(s):  
Ye. D. Golovanov ◽  
N. N. Maslov ◽  
Ye. V. Nakoryakova ◽  
T. V. Osipova ◽  
S. N. Kozheko

Results of cerebral hemodynamics condition assessment in dependence on central hemodynamics and biological aging rate are given in the article. Peculiarities of blood flow which influence on the development of chronic brain ischemia and mechanisms of its cellular compensation are revealed.


2003 ◽  
Vol 26 (2) ◽  
pp. 105-112 ◽  
Author(s):  
F. Gastaldon ◽  
A. Brendolan ◽  
C. Crepaldi ◽  
P. Frisone ◽  
S. Zamboni ◽  
...  

The main target for low flux hemodialyzers is an efficient low molecular weight solutes clearance. Such efficiency is largely dependent on the optimization of diffusion between blood and dialysis solution. The diffusion process can be impaired if there is a mismatch between blood and dialysate flow distribution in the dialyzer. Thus optimized flow distribution both in the blood and dialysate compartment becomes quintessential for the maximal efficiency of the diffusion process within the hemodialyzer. The present paper describes the distribution of the blood and dialysate flows in a new low flux polysulfone hollow fiber hemodialyzer characterized by a specific undulation of the fibers and a new cutting technology of the fibers for an improved micro-flow condition in the blood compartment headers. Twelve Diacap α Polysulfone LO PS 15 (1.5 sqm) (B.Braun Medizintechnologie, Melsungen Germany) were employed for the study. Six were analyzed in vitro and six were studied in vivo. Blood flow distribution was studied in vitro by dye injection in the blood compartment during experimental extracorporeal circulation utilizing human blood with hematocrit adjusted at 33%. Sequential images were obtained with a helical scanner in a fixed longitudinal section of the dialyzer 1 cm thick. Average and regional blood flow velocities were measured utilizing the reconstructed imaging sequence. The method allowed the calculation of single fiber blood flow (SF Qb) and the mass transfer zone (MTR) definition in digitally subtracted images. The patterns 20–10 and 40–30 were utilized. The same technology was used to evaluate flow distribution in the dialysate compartment after dye injection in the Hansen's connector. Regional dialysate flow was calculated in central and peripheral sample areas of 1 cm2. Six in vivo hemodialysis treatments on patients with end stage renal disease were performed at three different blood flow rates (250–350 and 450 ml/min) in order to measure urea, creatinine and phosphate clearance. Macroscopic and densitometrical analysis revealed that flow distribution was homogeneous in the blood compartment while in the dialysate compartment a slight difference between the peripheral and central regions in terms of flow velocity was observed. This however was not generating channeling phenomena. Urea creatinine and phosphate clearances were remarkably high and so were the Kt/V observed in all sessions, especially in relation to the studied blood flows. In conclusion, a significant blood to dialysate flow match with optimized countercurrent flow condition was observed in the studied hollow fiber hemodialyzers. Such optimization might be due both to the improved dialyzer design at the level of the blood header and to the specific fiber undulation that prevents dialysate channeling.


Author(s):  
John L. Beggs ◽  
Peter C. Johnson ◽  
Astrid G. Olafsen ◽  
C. Jane Watkins

The blood supply (vasa nervorum) to peripheral nerves is composed of an interconnected dual circulation. The endoneurium of nerve fascicles is maintained by the intrinsic circulation which is composed of microvessels primarily of capillary caliber. Transperineurial arterioles link the intrinsic circulation with the extrinsic arterial supply located in the epineurium. Blood flow in the vasa nervorum is neurogenically influenced (1,2). Although a recent hypothesis proposes that endoneurial blood flow is controlled by the action of autonomic nerve fibers associated with epineurial arterioles (2), our recent studies (3) show that in addition to epineurial arterioles other segments of the vasa nervorum are also innervated. In this study, we examine blood vessels of the endoneurium for possible innervation.